• 제목/요약/키워드: Power Measurement

검색결과 4,649건 처리시간 0.031초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

검안렌즈 표준화의 필요성과 규격에 관한 연구 (The Necessity and Requirement of Trial Lens Set Standardization)

  • 박상열
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.217-223
    • /
    • 2006
  • 본 연구를 하게 된 목적은 전국의 약 7681개의 안경업소와 안과병 의원 그리고 콘택트렌즈 전문점에서 타각적 굴절 검사를 한 후 자각적 굴절 검사를 하기 위해 사용하는 검안렌즈세트(Trial lens set)가 표준화 된 규격이 미흡하고 안광학적 허용 오차도 규정되어 있지 않고 표기된 굴절력과 실제 렌즈 도수가 상의한 것이 많아 이를 개선하고 검안렌즈 규격에 표준화를 만들고자 이 연구를 하게 되었다. 연구방법으로는 검안렌즈 세트를 사용하는 안경사들을 대상으로 보수교육을 통해 설문조사를 실시하고 국내에서 사용하는 제품과 수입 제품을 사용하는 안경원을 설정하여 이들이 사용하는 김안렌즈 세트를 사용하기에 따라 5년 미만, 5~10년, 10년 이상 각 5곳씩 검안렌즈를 선정하였으며, 표기된 굴절력과 실제렌즈를 측정하여 일본공업규격(JIS T4402)과 비교 분석하여 보았다. 분석결과를 살펴보면 검안렌즈를 사용하는 사람들이 사용 중인 접안렌즈의 굴절력에 대한 신뢰성이 응답자의 80% 이상을 차지하고 구입후 한 번도 표기된 굴절력과 실제도수를 측정해보지 않았다. 또한 한국산업규격(KS P4402)은 1979년도에 제정되어서 현재 사용하는 렌즈세트에서 빠지는 도수가 많다. 응답자의 95% 이상이 시력검사시 불편함을 느끼고 있다. 또한 굴절력에 대한 오차는 사용기간이 오래된 검안렌즈 일수록 오차가 큰 것을 알 수 있었다. 결론은 우리나라도 검안렌즈 규격을 표준화시키고 한국산업규격(KS P4402)에서 규정된 렌즈 세트에서 빠지는 도수에 대한 렌즈 세트를 추가시켜야 된다고 생각한다. 그리고 표준화된 검안렌즈를 검사 및 관리 감독하는 기관도 만들어야 한다고 생각한다. 국내에서 생산하는 제품이나 외국에서 수입되는 제품도 독일이나 일본처럼 안광학적 허용오차를 규정히여 이를 검사하고 규격에 맞는 검안렌즈 세트가 유통되기를 바란다. 국민의 안보건 향상과 시기능 관리를 위해서 정확한 시력검사를 해야 하고 누구나 똑같은 표준화된 검안렌즈 세트를 사용하고 규격과 허용오차 범위를 벗어나지 않는 검안렌즈 세트가 규정되길 바란다.

  • PDF

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

경주시 양북면 단층암의 광물 조성과 입도 분포 특징 (Mineral Composition and Grain Size Distribution of Fault Rock from Yangbuk-myeon, Gyeongju City, Korea)

  • 송수정;추창오;장천중;장태우;장윤득
    • 자원환경지질
    • /
    • 제45권5호
    • /
    • pp.487-502
    • /
    • 2012
  • 경주시 양북면 용당리에 발달한 단층암을 대상으로 X선 회절 분석(XRD), 광학현미경 분석, 레이저 입도 분석, 프랙탈 차원 분석을 적용하여 단층암의 광물 조성과 미구조, 잔류입자의 분포 특성을 연구하였다. 단층핵은 약 1.5 m 두께로 발달하며 이 중 각력대는 약 1.2m, 단층핵의 가장 중심부인 비지대는 평균 20cm의 얇은 두께로 노출되어 있다. 각력대에서는 석영, 장석류 등의 조암광물이 주 구성 광물로서 산출되고 비지대에서는 녹니석, 일라이트 등의 점토광물이 주 구성 광물로서 산출된다. 단층암에서 빈번하게 산출되는 맥상광물, 황철석, 변질 광물 등은 단층활동과 더불어 열수변질 작용이 수반되었음을 시사하고 있다. 현미경에 의한 구획 점셈(box counting), Image J에 의한 영상분석 및 레이저 입도 분석에 기초한 프랙탈 차원값은 단층암의 입자 파쇄 특성을 잘 보여준다. 세 가지 방법으로 구한 프랙탈 차원값(D)은 각력대에서 비지대로 갈수록 그 값이 증가하고 비지대 내에서는 공통적으로 높은 차원값을 갖는다. 비지대 내에서는 D값의 변화가 상대적으로 적으며, 일정한 경향성이 나타나지 않는다. 이는 각력대에서는 입자들의 대량파쇄가 우세하게 발생하고, 단층운동이 계속되어 생성된 비지대에서는 입자의 마모가 보다 우세하게 발생하였음을 시사한다. 연구지역 단층암의 광물 조성과 입자 분포 특성은 다중 단층 운동과 열수변질 작용이 본 연구지역 단층대의 진화에 큰 영향을 끼쳤음을 지시한다. 단층암에서의 프랙탈 차원값이 측정 기법에 따라 차이가 발생하므로 프랙탈 차원값의 상대적인 비교는 보다 신중히 이용되어야 될 것으로 생각된다.

흑마늘 추출액을 첨가한 식빵의 품질 특성 (Quality Characteristics of Bread with Added Black Garlic Extract)

  • 양승미;신정혜;강민정;김성현;성낙주
    • 한국식품조리과학회지
    • /
    • 제26권5호
    • /
    • pp.503-510
    • /
    • 2010
  • 흑마늘 추출액을 총 재료 중량에 대해 0, 1, 3, 6, 9 및 12%(W/W) 첨가하여 제조한 식빵의 품질 특성을 분석하였다. 반죽의 pH는 흑마늘 추출액 첨가에 따라 유의적으로 낮아져, 흑마늘 추출액을 12% 첨가한 시료에서 $5.46{\pm}0.02$로 가장 낮았으며, 반죽의 밀도도 유사한 경향을 보여 12% 첨가시 $0.95{\pm}0.03\;g/mL$로 가장 낮았다. 반죽의 발효 팽창력은 흑마늘 추출액 첨가군에서 $143.08{\pm}0.61{\sim}143.63{\pm}0.25%$의 범위로 대조군과 유의차가 없었다. 소성 후 식빵의 pH는 $6.87{\pm}0.01{\sim}7.75{\pm}0.02$로 흑마늘 추출액의 첨가량이 증가함에 따라 유의적으로 감소하였으며, 식빵의 비용적은 $2.33{\pm}0.27{\sim}2.74{\pm}0.51\;mL/g$의 범위로 대조구와 실험구간에 유의적인 차이를 보이지 않았다. 식빵 겉껍질과 내부색 모두 명도값은 흑마늘 추출액을 첨가량이 증가함에 따라 대조구에 비해 감소하는 경향을 나타내었으며, 적색도와 황색도는 증가하는 경향을 보였다. 텍스쳐를 측정한 결과 견고성은 흑마늘 추출액 1% 첨가구에서 가장 높은 $277.82{\pm}32.55$였으며, 씹힘성과 검성은 흑마늘 추출액의 첨가량이 증가함에 따라 점차 감소하는 경향이었다. 응집성은 흑마늘 추출액 12% 첨가구에서 가장 높아 $0.33{\pm}0.07$ 이였고, 복원성은 흑마늘 추출액 3% 이상 첨가시 $0.12{\pm}0.04{\sim}0.16{\pm}0.04$의 범위로 대조구 및 1% 첨가구보다 유의적으로 낮았다. 관능검사 결과 색과 전체적인 기호도는 대조구와 실험구간에 유의차가 없었으나, 맛은 흑마늘 추출액 6% 첨가구에서 가장 높았다. 이상의 결과들을 종합하여 볼 때 흑마늘 추출액을 첨가하여 식빵을 제조할 경우 제빵 적성, 빵의 품질 개선 및 기호성과 기능성이 향상된 식빵을 제조 할 수 있을 것으로 생각된다.

광대역 위성 통신/방송용 삼중 대역 이동형 안테나 시스템 설계에 관한 연구 (A Study on Mobile Antenna System Design with Tri-band Operation for Broadband Satellite Communications and DBS Reception)

  • 엄순영;정영배;손성호;윤재승;전순익
    • 한국전자파학회논문지
    • /
    • 제17권5호
    • /
    • pp.461-475
    • /
    • 2006
  • 본 논문은 Ka/K 통신 대역 및 Ku 방송 대역에서 동작하는 무궁화 3호 정지 궤도 위성을 이용하여 화상 전화, 인터넷과 같은 위성 멀티미디어 및 방송 서비스를 제공하는 이동체 탑재형 안테나 시스템 설계에 관한 것이다. 앙각 방향으로 팬 빔 특성을 갖는 안테나 시스템의 방사부는 준-오프셋 이중 성형 반사판과 삼중 대역 급전기로 구성된다. 또한, 삼중 대역 급전기는 돌출 유전체 막대를 이용한 Ka/K 이중 대역 급전기 및 원형 편파기, 직교 모드 변환기 그리고 Ku 대역 원형 편파 급전 배열로 구성된다. 특히, Ka/K 이중 대역 원형 편파기는 제작이 용이한 comb 구조를 사용하여 구현되었다. Ku 대역 급전 배열은 이동시 위성을 고속으로 추적하기 위하여 전자 빔을 형성할 수 있는 $2{\times}2$ 능동 위상 배열 구조를 갖는다. 그리고, 급전 배열에서 $90^{\circ}$ 하이브리드 결합기를 이용하여 원형 편파를 생성하는 4개의 방사 소자들을 $90^{\circ}$씩 회전하여 배열함으로써 원형 편파 특성을 개선하였다. Ku 대역 전자 빔을 생성하는 4개의 빔 성형 채널은 출력에서 주 빔 채널 및 추적 빔 채널로 구분되며, 각 채널의 내부 구성 유니트들의 잡음 온도 기여도를 바탕으로 채널 잡음 온도 특성을 분석하였다. 제작된 안테나 시스템으로부터 측정된 Ka 송신 채널의 $P_{1dBc}$ 출력은 34.1 dBm 이상, K/Ku 수신 채널의 잡음 지수는 각각 2.4 dB 및 1.5 dB 이하의 전기적인 성능들을 보여주었다. 안테나 시스템은 근접 전계 측정 방법을 사용하여 삼중 대역에서의 주 편파 및 교차 편파 방사 패턴들을 측정하였다. 특히, Ku 대역의 방사 패턴 측정은 급전 배열들의 독립 여기에 의한 부분 방사 패턴들을 측정하여 각 능동 채널들의 초기 위상들을 보정한 후 이루어졌다. 안테나 시스템의 Ka/K/Ku 대역에서 측정된 안테나 이득은 각각 39.6 dBi, 37.5 dBi, 29.6 dBi 이상이었으며, 그리고 Ka 대역 송신 EIRP는 43.7 dBW 이상, K/Ku 대역 수신 감도 G/T는 각각 13.2 dB/K와 7.12 dB/K 이상의 우수한 시스템 성능들을 보여주었다.

선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성 (Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance)

  • 이정우;홍세미;박병문;강민영;김유현;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.183-188
    • /
    • 2008
  • 본 연구의 목적은 방사선치료용 선형가속기의 품질관리를 수행하기 위한 2차원이온전리함배열의 유용성을 검증하기 위함이다. 물팬톰과 필름으로 수행하던 기존의 품질관리 방법을 2차원이온전리함배열(MatriXX, Wellhofer Dosimetrie, Germany)을 이용하여 유용성을 검증하였다. MatriXX는 1,020개의 평판형 전리함(용적: $0.08\;cm^3$, 직경: 4.5mm, 높이: 5mm, 배열간격: 7.62mm)이 일정한 간격으로 $24{\times}24\;cm^2$의 면적에 배열 되어있다. MatriXX의 유용성을 검증하기 위해 연속된 5개월에 걸쳐 선량균등도, 에너지($TPR_{20,10}$), 그리고 절대 선량을 측정하여 물팬톰과 $0.65\;cm^3$ (FC65G, Wellhofer Dosimetrie, Germany) Farmer형 이온전리함을 통해 얻은 값과 비교, 분석하였다. MatriXX 측정 시 폴리스틸렌 고체 팬톰(${\rho}:\;1.18\;g/cm^3$)을 이용하였으며, MatriXX 고유의 커버 물질의 밀도와 두께(${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm)를 물과 등가의 값으로 환산하여 적용하였다. 또한, 기하학적 점검을 위한 예비실험에서 콜리메이터의 회전축과 하프빔의 접합부를 필름측정의 결과와 비교하였다. 선량계측학적 실험 결과, MatriXX로 얻은 데이터와 물팬톰의 결과가 모든 항목에서 ${\pm}1%$ 이내의 일치를 보였다. 기하학 품질관리의 예비 실험 결과 기존의 필름방식과 유사한 결과를 얻었으며, 기하학적 품질관리의 정량적 분석 가능성을 제시하였다. 본 연구를 통해 주기적인 선형가속기의 품질관리에서 물팬톰과 필름을 대체할 수 있는 MatriXX의 유용성을 확인하였으며, 향후 비용절감과 시간과 인력을 절감할 수 있는 품질관리의 새로운 방법을 제시하였다.

  • PDF

L, C, X-밴드 레이더 산란계 자동측정시스템을 이용한 콩 생육 모니터링 (Monitoring soybean growth using L, C, and X-bands automatic radar scatterometer measurement system)

  • 김이현;홍석영;이훈열;이재은
    • 대한원격탐사학회지
    • /
    • 제27권2호
    • /
    • pp.191-201
    • /
    • 2011
  • 본 연구에서는 다편파 레이더 산란계 자동 측정시스템 이용하여 콩 생육변화를 관측하고 레이더 시스템에서 얻어진 후방산란계수과 콩 생육인자들과의 관계분석을 통하여 콩 생육추정 가능성을 모색하고자 하였다. 2010년도 농촌진흥청 국립식량과학원 연구지역에 다편파 레이더 산란계 관측시스템 (L, C, X-밴드 안테나, 네트워크분석기, RF switch, 입사각 $40^{\circ}$)을 구축하고 콩 파종시기에서 수확기까지 10분단위로 콩 생육변화를 자동 측정하였다. 모든 안테나 밴드, 편파에서 콩 생육초기 (6월초~7월 중순)에는 VV-편파가 HH-, HV-편파보다 후방산란계수가 높게 나타났고, 그 이후 HH-편파와 다른 편파들 간의 cross-over 현상이 일어났는데 그 시기는 L-밴드가 7월 20일 (DOY 200), C-, X-밴드의 경우에는 7월 30일 (DOY 210)로 밴드에 따라 차이를 보였다. 모든 밴드 및 편파에서 9월 29일 (DOY 271)까지 후방산란계수가 증가하다가 그 이후 감소하였고 특히 종실비대기 (DOY 277, R6) 이후 감소폭이 크게 나타났는데 이 현상은 콩 생육인자 (초장, 엽면적지수, 건물중 등)변화와 일치하였다. 밴드에 따른 후방산란계수와 콩 생육인자들과의 관계를 분석한 결과 L-밴드 HH-편파에서 LAI ($r=0.93^{***}$), 초장 ($r=0.95^{***}$), 건물중 ($r=0.94^{***}$), 꼬투리중 ($r=0.92^{***}$)등 콩 생육인자들과의 상관계수가 가장 높게 나타났고 이에 비해 X-밴드 편파에서는 콩 생육인자들과의 상관계수가 상대적으로 낮게 나타났다. 후방산란계수 (L-밴드 HH-편파)를 이용하여 콩 생육인자 추정을 위한 회귀식을 작성하였다.

굴절이상 교정상태에 따른 동적시력 변화 (Changes in KVA Resulting from Correction Condition of Refractive Error)

  • 심현석;김상현;강혜숙
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.165-171
    • /
    • 2013
  • 목적: 남녀 대학생의 동공크기, 손의 반응력, 굴절이상, 교정시력, 우위안, 정지시각(static visual angle, SVA), 동적시력(kinetic visual acuity, KVA)등을 비교 분석하고, 굴절이상이 완전교정 된 상태에서 남녀 대학생의 KVA를 측정하고, 완전교정상태에 구면굴절력 ${\pm}0.50 $D를 각각 변화시켜 KVA을 측정하여 변화를 알아보고자 하였다. 방법: 안경광학과 남학생 40명, 여학생 40명을 대상으로 KVA 측정장치(KOWA AS-4A)와 손의 반응력 측정 프로그램, 자 타각적 굴절검사기기 등을 이용하여 KVA, SVA, 동공크기, 손의 반응력, 굴절이상, 교정시력, 우위안 등을 측정하였고, 양안 구면굴절력을 ${\pm}0.50$ D 변화시켜 KVA를 측정하였다. 결과: 전체 대상자의 양안 KVA는 $0.45{\pm}0.22$이고, 단안은 우안 $0.36{\pm}0.19$, 좌안 $0.34{\pm}$0.19로 양안이 단안보다 유의하게 높게 나타났다. SVA가 좋을수록 KVA가 유의하게 좋은 것으로 나타났으며, 굴절이상은 근시량이 작을수록 KVA가 좋았으나 통계적으로 유의하지 않았다. 난시에서는 -1.00 D 이하와 초과로 나눌 때 난시가 작을수록 KVA가 유의하게 좋았다. 굴절이상 교정상태에 따른 KVA는 완전교정일 때 $0.45{\pm}0.22$, 완전교정에 +0.50 D 추가할 때 $0.26{\pm}0.15$, 완전교정에 -0.50 D 추가할 때 $0.48{\pm}0.22$로 근시 교정을 강하게 할 때가 유의수준에서 KVA가 가장 높게 나타났으며, 다음으로 완전교정, 근시 저교정의 순으로 낮게 나타났다. 또한 남녀로 구별하여 비교해 볼 때도 유사한 결과를 나타냈으며 남자가 여자보다 KVA가 좋은 것으로 나타났다. KVA와 우위안 비우위안 차이는 없었다. 결론: 따라서, KVA는 원거리 SVA, 난시량, 굴절이상량과 관계가 있는 것을 알 수 있었으며, 우위안과는 관계가 없었다. KVA를 높이는 굴절이상 처방은 완전교정 또는 근시방향에서 약간 과교정 하는 것이 효과적인 것을 알 수 있었다.