• Title/Summary/Keyword: Power Line Interference

Search Result 201, Processing Time 0.028 seconds

Design of IIR Notch Filter for Removal of Baseline wander and Power Line Interference from ECG Signal

  • Chivapreecha, Sorawat;Dejhan, Kobchai;Yimman, Surapan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.848-851
    • /
    • 2005
  • This paper proposes a design of IIR notch filter with modified pole placements. The pole angle is derived from quadratic programming to find the appropriate pole position on the unit circle in z-plane in order to achieve the symmetry of the amplitude response. The simulation results are shown when compared with the conventional design technique. Moreover, it uses the TMS320C31 DSP chip for hardware implementation. Finally, the hardware implementation can be applied to removal of ECG baseline wander and elimination of AC power line interference in ECG signal.

  • PDF

Analysis of the inductive interference on the conductor around power system (송전선로 주위의 도체에 미치는 유도장해 해석)

  • Choi, Se-Yong;Nah, Wan-Soo;Choi, Myung-Jun;Lee, Se-Hee;Kim, Dong-Hun;Park, Il-Han;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1034-1037
    • /
    • 1999
  • In this paper, we analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as electromagnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics of conductive material such as gas pipeline, overhead guide wires, conducting earth and so on are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried gas pipe line.

  • PDF

Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber (새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성)

  • Sung, Chi-Ho;Heo, Young-Hwan;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

A Study of Interference-Free Home PLC based on the Binary ZCD Code (연속직교 상관특성을 갖는 아진 코드 기반의 구내용 PLC에 관한 연구)

  • Cha, Jae-Sang;Kim, Seong-Kweon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.38-44
    • /
    • 2006
  • In this paper, a new interference-free Home CDMA-PLC(Code Division Multiple Access-Power Line Communication) system based on the binary ZCD(Zero Correlation Duration) spreading code is proposed as a key solution to overcome the previous problems. Binary ZCD spreading code sets with enlarged family sizes are generated by carrying out a chip-shift operation of the preferred pairs. The properties or the proposed ZCD-PLC systems are effective for MPI(Multi-Path Interference) and MAI (Multiple Access Interference) cancellation in the CDMA-PLC systems. By BER performance simulation, we certified the availability of proposed ZCD-CDMA-PLC system.

On-line self-tuning PID power controller using fuzzy logic for CDMA cellular systems (퍼지 논리를 이용한 온라인 자기동조기능을 갖는 CDMA 셀룰러 시스템용 PID 전력제어기)

  • 김상민;한진욱;김성중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.211-214
    • /
    • 1997
  • This paper applies fuzzy self-tuning PID controller in DS/CDMA cellular system. Power control is essential in DS/CDMA to compensate for the differing received powers due to both the slowly varying long-term and fast varying short-term fading processes and co-channel interference. The controller proposed is adaptable for the variations of the system dynamics and especially for the variable time delay which exists in mobile radio systems. Accordingly the results is the smaller power control error, that is, the smaller average transmitting power of mobile compared with the conventional control schemes. Because interferences to the other mobiles are reduced, the capacity of CDMA can be increased.

  • PDF

A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC) (전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구)

  • Kim, Yong-Tae;Shin, Kwan-Woo;Lee, Youn-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

Prediction of Noise Power Disturbance from Antenna to Transmission Line System (안테나로부터 인접 전송선로에 전달되는 노이즈 전력 예측)

  • Ryu, Soojung;Jeon, Jiwoon;Kim, Kwangho;Jo, Jeongmin;Lee, Seungbae;Kim, SoYoung;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1172-1182
    • /
    • 2014
  • In these days, many kinds of goods are more light and more integrated. As frequency range of mobile applications have increased to improve performance of antenna furthermore, EMI(ElectroMagnetic Interference) problem has frequently caused by disturbance of antenna in device which aggravates other circuit. This paper proposes a technique for the prediction of noise power to the transmission line from antenna located near the line. Although noise power transferred to transmission line is varied by source impedance of antenna and load impedance of transmission line basically, the power magnitude can be presented in a square form of S-parameter between antenna and transmission line due to small variation of transferred power. For this reason, we can use the index expressed the transferred power varied along geometrical shapes of transmission line. As a result, big difference is occurred along location of antenna especially the bended line. And this such experiment is correspond with simulation, these results have meaning physically considering electromagnetic field distribution in near and far field. HFSS of Ansys and CPW with ground is used in this paper.

Implementation of a Dynamic High-performance Notch Filter applying CIC Filter Scheme (CIC Filter 기법을 적용한 동적 고성능 Notch Filter 구현)

  • Shin, Seong-Kyun;Jeong, Won-Ho;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.1-8
    • /
    • 2011
  • Power Line Communication (PLC: Power Line Communication) to propagate the current power lines are in every household of the existing infrastructure is the most extensive network configuration. In addition, the cost required for network configuration, the advantage of almost zero for the investors and is sufficient to attract the attention of operators. The PLC is supply power to power lines used the voice and data communication technologies put it on KHz ~ tens of hundreds of high-frequency signal MHz. But because uses power lines as existing wireless communications systems will occurs interference. The notch filters of a common way to eliminate the interference are used. In this paper, a dynamic high-performance notch filter applying CIC filter performance was verified through MATLAB and was implemented using a TI's TMS320C6416T DSP board.

Adaptive Subtraction Method for Removing Variable Powerline Interference of ECG (ECG 신호의 가변적인 전력선 잡음 제거를 위한 적응형 차감기법)

  • Jeon, Hong-Kyu;Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.447-454
    • /
    • 2011
  • Power-line interference(PLI) can distort certain regions in analysing the ECG signal. In particular, the regions such as P and R wave that are important element in diagnosing with arrhythmia is expressed as different type of noise according to the case whether power-line frequency is multiples of sampling frequency and or not. Noise characteristics is also divided into linearity and non-linearity. In this paper, adaptive subtraction method for removing variable PLI of ECG signal is proposed. We classify the multiple relationship between power line and sampling frequency as Multiple and Non-multiple. PLI of Linear segment is extracted through moving average filter, PLI of non-linear segment is extracted through the interference component that is extracted in the linear segment and stored in the temporary buffer. The performance of P wave and R wave detection is evaluated by using 119 data record of MIT-BIH arrhythmia database. The achieved scores indicate P wave detection rate of 97.91%, R wave detection rate of 96.66% and P wave detection rate of 99.01%, R wave detection rate of 97.93% accuracy respectively for Notch filter and proposed subtraction method.

A Study on The Effects of AC Corrosion on Underground Gas Pipeline Running Parallel with High Power Cables (Case II) (편력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구(II))

  • Bae, Jeong-Hyo;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.74-79
    • /
    • 2002
  • We have been analyzed the interference problems already in steady state, especially AC corrosion when the gas pipeline is burred with power cable in the same submarine tunnel. In the next stage, we analyze the induced voltage in a fault condition of 154[kV] underground T/L. This paper presents the results of them which are limitation of safety voltage. meodeling of power cables, gas pipeline and grounding systems, analysis of induced voltage in a fault condition, and protection of Power line system.