• Title/Summary/Keyword: Power Lift

Search Result 387, Processing Time 0.035 seconds

SW05 Rotor Lift of an Unmanned Helicopter for Precise ULV Aerial Application (초미량 정밀살포용 무인헬리콥터의 SW05 로터 양력시험)

  • Koo, Young-Mo;Seok, Tae-Su;Shin, Shi-Kyoon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • A small unmanned helicopter was suggested to replace the conventional spray system. Aerial application using an agricultural helicopter helps precise and timely spraying, and reduces labor intensity and environmental pollution. In this research, a rotor system (SW05) was developed and its lift capability was evaluated. Lift force for the dead weight of the helicopter was obtained at the grip pitch angle of $12^{\circ}$. As the pitch angle increased to $14^{\circ}$ and $16^{\circ}$, the payload increased to 176 N and 216 N, respectively. Compared with SW04 airfoil performance in the total lift, the SW05 airfoil showed nearly the same capacity, but the payload of the SW05 was reduced because of the increased dead weight. A rated flight condition was defined as lifting mean payload of 294 N with the grip pitch angles of $16{\sim}17^{\circ}$ at the rotor rotating speed of 850~950 rpm for the adjusted engine power. The fuel consumption would be 4.8~6.0 L/hr, and the air temperature of cooling fan should be kept below $160^{\circ}C$.

Optimal Dimple Point of SFF HDD Suspension for Improving the Unloading Performance (언로드 성능 향상을 위한 딤플 포인트의 최적설계)

  • Kim, Ki-Hoon;Lee, Young-Hyun;Lee, Hyung-Jun;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.609-612
    • /
    • 2007
  • The HDD (hard disk drive) using Load/Unload (L/UL) technology includes the benefits which are increased areal density, reduced power consumption and improved shock resistance than those of contact-start-stop (CSS). Dynamic L/UL has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main design objectives of the L/UL mechanisms are no slider-disk contact or no media damage even with contact during L/UL, and a smooth and short unloading process. In this paper, we focus on lift-off force, pitch static attitude (PSA), roll static attitude (RSA) and dimple point. The "lift-off" force, defined as the minimum air bearing force, is another very important indicator of unloading performance. A large amplitude of lift-off force increases the ramp force, the unloading time, the slider oscillation and contact-possibility. PSA and RSA are also very important parameters in L/UL system and stability of slider is mainly determined by PSA and RSA. Dimple point by PSA and RSA is also important indicator. Therefore we find the optimal dimple point of SFF HDD suspension for improving the unloading performance.

  • PDF

Design of a Winch Lift for a Scooter to Get On and Off a Coach Van (스쿠터 승하차를 위한 밴승합차용 윈치 리프트 설계)

  • Lee Dug-Young;Youn Jae-Woong;Lee Soo Cheol;Lim Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.189-196
    • /
    • 2005
  • The numbers of the elder are rapidly growing who wants to enhance social activities, because Korea is already an aging society since 2000. The mobility and accessibility are the key issues to enhance them. The electric motor scooter and the power wheel chair are efficient movable means at a short range. It would be needed to get on and off them if the elder wants use them after arriving a long distant destination. But the electric scooter is too heavy for a man to get on and off a coach van. The motor winch lift is developed for the elder and the handicapped to get on and off a van easily. The lift consists of 3-linkage which can be installed in a trunk of a van with a small space. The clearance and stress of each component are checked by a computer simulation. The prototype was made. and the performances of safety and comfortableness were verified by operational ability test and durability test.

PI Controlled Active Front End Super-Lift Converter with Ripple Free DC Link for Three Phase Induction Motor Drives

  • Elangovan, P.;Mohanty, Nalin Kant
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.190-204
    • /
    • 2016
  • An active front end (AFE) is required for a three-phase induction motor (IM) fed by a voltage source inverter (VSI), because of the increasing need to derive quality current from the utility end without sacrificing the power factor (PF). This study investigates a proportional-plus-integral (PI) controller based AFE topology that uses a super-lift converter (SLC). The significance of the proposed SLC, which converts rectified AC supply to geometrically proceed ripple-free DC supply, is explained. Variations in several power quality parameters in the intended IM drive for 0% and 100% loading conditions are demonstrated. A simulation is conducted by using MATLAB/Simulink software, and a prototype is built with a field programmable gate array (FPGA) Spartan-6 processor. Simulation results are correlated with the experimental results obtained from a 0.5 HP IM drive prototype with speed feedback and a voltage/frequency (V/f) control strategy. The proposed AFE topology using SLC is suitable for three-phase IM drives, considering the supply end PF, the DC-link voltage and current, the total harmonic distortion (THD) in supply current, and the speed response of IM.

A Study on System Configuration of Grid-connected CTTS System with Soft Switching (소프트 절환이 가능한 계통 연계형 CTTS 시스템 구성에 관한 연구)

  • Lee, Hyoung-Mook;Yang, Ji-Hoon;Lee, Jung-Hwan;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.361-368
    • /
    • 2018
  • This paper proposes a grid - connected CTTS system that can be soft switched to meet the government's effective resource allocation policy for emergency generator. In order to eliminate the system instability caused by the large inrush current generation in the system switching, a new virtual rotation coordinate method for the dissimilar power source is proposed. The proposed virtual rotation coordinate method improves the voltage detection accuracy of the voltage difference of the dissimilar power supply, and it is proved that the synchronous switching characteristic is excellent. In addition, zero current and system stabilization can be achieved by realizing zero current when blocking CTTS with instantaneous reactive power control. Simulation was carried out to verify the validity of the proposed method, and the 500[kVA] system was fabricated and verified to demonstrate the superiority of the proposed method.

Performance Analysis of Stabilizer Fin Applied Coanda System (코안다 시스템이 장착된 안정기용 핀의 성능해석)

  • Seo, Dae-Won;Lee, Se-Jin;Oh, Jungkeun
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • Stabilizer fins are installed on each side of a ship to control its roll motion. The most common stabilizer fin is a rolling control system that uses the lift force on the fin surface. If the angle of attack of a stabilizer fin is zero or the speed is zero, it cannot control the roll motion. The Coanda effect is well known to generate lift force in marine field. The performance of stabilizer fin that applies the Coanda effect has been verified by model tests and numerical simulations. It was found that a stabilizer fin that applied the Coanda effect at Cj = 0.085 and a zero angle of attack exactly coincided with that of the original fin at α = 26°. In addition, the power needed to generate the Coanda effect was not high compared to the motor power of the original stabilizer fin.

Across-wind dynamic loads on L-shaped tall buildings

  • Li, Yi;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.385-403
    • /
    • 2016
  • The across-wind dynamic loads on L-shaped tall buildings with various geometric dimensions were investigated through a series of wind tunnel testing. The lift coefficients, power spectral densities and vertical correlation coefficients of the across-wind loads were analyzed and discussed in details. Taking the side ratio and terrain category as key variables, empirical formulas for estimating the across-wind dynamic loads on L-shaped tall buildings were proposed on the basis of the wind tunnel testing results. Comparisons between the predictions by the empirical formulas and the wind tunnel test results were made to verify the accuracy and applicability of the proposed formulas. Moreover, a simplified procedure to evaluate the across-wind dynamic loads on L-shaped tall buildings was derived from the proposed formulas. This study aims to provide a simple and reliable way for the estimation of across-wind dynamic loads on L-shaped tall buildings.

Electric Charges Reducing Device through Power Trading between Neighbors (이웃 간의 전력거래를 통한 전기요금 저감 장치)

  • Jeong, Da-Woom;Lee, Jung-Hwan;Park, Seong-Mi;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.373-374
    • /
    • 2016
  • 전기 수요자의 다양성에 따라 새로운 전기 법규가 제정되고 있으며, 이에 대응하여 프로슈머(Prosumer)에 의한 이웃 간의 전력거래 움직임이 활발히 논의 되고 있다. 본 논문은 프로슈머가 아니더라도 이웃 간의 전력거래가 허가된다면, 전력거래를 통한 누진 요금을 저하 할 수 있는 가정용 Facts 전력 변환기 시스템을 제안한다. 제안된 이웃 간의 가정용 Facts의 타당성을 검증하기 위해 PSIM에 의한 시뮬레이션을 통하여 전기요금의 저감을 분석 하였다.

  • PDF

A Study on Oxygen Dissolution by Air Lift Pump (기포 펌프에 의한 산소 용해에 관한 연구)

  • Oh, S.K.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.45-50
    • /
    • 1999
  • 기포 펌프는 물과 공기 사이의 접촉 면적을 증가시켜 공기로부터 물로의 산소 용해를 높이는 기능을 가지고 있다. 이 연구에서는 기포 펌프에서 여러 가지 흐름 패턴을 설정하고, 이것을 근거로 하여 슬립모델을 확립하여, 기포 펌프의 산소 용해 특성을 조사하였다. 이 연구에서 수행한 실험 결과로부터, 산소 전달 계수는 흐름 패턴(기포 흐름, 기포-슬러그 흐름, 슬러그 흐름)에는 상당한 영향을 받았으나, 시료수의 오염 정도에 따른 영향은 그다지 크지 않음을 확인하였다. 그리고, 산소 전달양은 레이놀즈 수에 비례하여 증가하며, 산소 전달면을 증가시키기 위해서는 에어 스톤이나 디퓨저의 이용이 매우 효과적임을 확인하였다. 또한, 표면 활성 물질은 물의 오염 정도나 흐름 패턴에 관계없이 산소 전달에 큰 영향을 미침을 알 수 있었다.

  • PDF

Investigation on the Hydrodynamic Characteristics of Double Plate Steel Rudder for Small Fishing Boat (소형 어선용 이중강판 방향타의 유체역학적 특성 조사)

  • An, N.H.;Park, H.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.24-29
    • /
    • 2012
  • In this study, the numerical simulation has been performed to investigate the hydrodynamic evaluation between double plate steel rudder and newly designed foil type rudder for small fishing boat. The simulations are carried out in 2 speed ranges with 7 variations of flow's angle of attack which is at intervals of about 5 degree respectively. As the well-known commercial code, FLUENT and CATIA are used as the solver. The simulation results show that new designed foil type rudder is better than conventional double plate rudder in terms of Lift and Drag of running boat in the water.