• 제목/요약/키워드: Power Information Technology

검색결과 5,106건 처리시간 0.035초

Optimal Cooperation and Transmission in Cooperative Spectrum Sensing for Cognitive Radio

  • Zhang, Xian;Wu, Qihui;Li, Xiaoqiang;Yun, Zi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권2호
    • /
    • pp.184-201
    • /
    • 2013
  • In this paper, we study the problem of designing the power and number of cooperative node (CN) in the cooperation phase to maximize the average throughput for secondary user (SU), under the constraint of the total cooperation and transmission power. We first investigate the scheme of cooperative spectrum sensing without a separated control channel. Then, we prove that there indeed exist an optimal CN power when the number of CNs is fixed and an optimal CN number when CN power is fixed. The case without the constraints of the power and number of CN is also studied. Finally, numerical results demonstrate the characteristics and existences of optimal CN power and number. Meanwhile, Monte Carlo simulation results match to the theoretical results well.

무선 충전 가능한 RTLS 태그 설계 (Design of Wireless Rechargeable RTLS Tag)

  • 김태용
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.59-60
    • /
    • 2015
  • 무선전력전송은 각종 전자기기에 필요한 전력을 전선 없이 무선으로 공급하는 기술이다. 무선전력전송 기술은 자기 코일을 이용하는 근거리 무선전력전송 기술과 안테나를 이용하는 원거리 무선전력전송 기술로 구분된다. 본 연구에서는 시설물 관리용 전원공급 문제를 해결하기 위한 방안으로 UWB를 활용하여 초정밀 측위가 가능한 RTLS 태그와 무선 충전부를 설계하였다. 무선 충전 패드는 자기 공진 방식을 이용하여 4개의 기기를 충전할 수 있는 기능을 제공한다.

  • PDF

Research on unsupervised condition monitoring method of pump-type machinery in nuclear power plant

  • Jiyu Zhang;Hong Xia;Zhichao Wang;Yihu Zhu;Yin Fu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2220-2238
    • /
    • 2024
  • As a typical active equipment, pump machinery is widely used in nuclear power plants. Although the mechanism of pump machinery in nuclear power plants is similar to that of conventional pumps, the safety and reliability requirements of nuclear pumps are higher in complex operating environments. Once there is significant performance degradation or failure, it may cause huge security risks and economic losses. There are many pumps mechanical parameters, and it is very important to explore the correlation between multi-dimensional variables and condition. Therefore, a condition monitoring model based on Deep Denoising Autoencoder (DDAE) is constructed in this paper. This model not only ensures low false positive rate, but also realizes early abnormal monitoring and location. In order to alleviate the influence of parameter time-varying effect on the model in long-term monitoring, this paper combined equidistant sampling strategy and DDAE model to enhance the monitoring efficiency. By using the simulation data of reactor coolant pump and the actual centrifugal pump data, the monitoring and positioning capabilities of the proposed scheme under normal and abnormal conditions were verified. This paper has important reference significance for improving the intelligent operation and maintenance efficiency of nuclear power plants.

Multi-Valued Logic Device Technology; Overview, Status, and Its Future for Peta-Scale Information Density

  • Kim, Kyung Rok;Jeong, Jae Won;Choi, Young-Eun;Kim, Woo-Seok;Chang, Jiwon
    • Journal of Semiconductor Engineering
    • /
    • 제1권1호
    • /
    • pp.57-63
    • /
    • 2020
  • Complementary metal-oxide-semiconductor (CMOS) technology is now facing a power scaling limit to increase integration density. Since 1970s, multi-valued logic (MVL) has been considered as promising alternative to resolve power scaling challenge for increasing information density up to peta-scale level by reducing the system complexity. Over the past several decades, however, a power-scalable and mass-producible MVL technology has been absent so that MVL circuit and system implementation have been delayed. Recently, compact MVL device researches incorporating multiple-switching characteristics in a single device such as 2D heterojunction-based negative-differential resistance (NDR)/transconductance (NDT) devices and quantum-dot/superlattices-based constant intermediate current have been actively performed. Meanwhile, wafer-scale, energy-efficient and variation-tolerant ternary-CMOS (T-CMOS) technology has been demonstrated through commercial foundry. In this review paper, an overview for MVL development history including recent studies will be presented. Then, the status and its future research direction of MVL technology will be discussed focusing on the T-CMOS technology for peta-scale information processing in semiconductor chip.

ADC-Based Backplane Receivers: Motivations, Issues and Future

  • Chung, Hayun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.300-311
    • /
    • 2016
  • The analog-to-digital-converter-based (ADC-based) backplane receivers that consist of a front-end ADC followed by a digital equalizer are gaining more popularity in recent years, as they support more sophisticated equalization required for high data rates, scale better with fabrication technology, and are more immune to PVT variations. Unfortunately, designing an ADC-based receiver that meets tight power and performance budgets of high-speed backplane link systems is non-trivial as both front-end ADC and digital equalizer can be power consuming and complex when running at high speed. This paper reviews the state of art designs for the front-end ADC and digital equalizers to suggest implementation choices that can achieve high speed while maintaining low power consumption and complexity. Design-space exploration using system-level models of the ADC-based receiver allows through analysis on the impact of design parameters, providing useful information in optimizing the power and performance of the receiver at the early stage of design. The system-level simulation results with newer device parameters reveal that, although the power consumption of the ADC-based receiver may not comparable to the receivers with analog equalizers yet, they will become more attractive as the fabrication technology continues to scale as power consumption of digital equalizer scales well with process.

태양광 대량보급 시대의 기술개발 (Technology Development in the Era of Photovoltaic Mass Supply)

  • 조은철;송재천;조영현;이준신
    • Current Photovoltaic Research
    • /
    • 제6권4호
    • /
    • pp.124-132
    • /
    • 2018
  • The Korean electric power supply plan was prepared by greatly enhancing the environmental and safety with considering the economical efficiency of the electric equipment, the impact on the environment and the public safety. As a result, the fossil energy-based power generation sector is accelerating the paradigm shift to eco-friendly energy such as solar power and wind. Also the solar power industry is expected to grow into a super large-sized industry by converging the energy storage and electric vehicle industry. Generally, a levelized cost of electricity (LCOE) is used to calculate the power generation cost for different generation power generation efficiency, operating cost, and life span. In this paper, we have studied the future research and development direction of photovoltaic technology development for the era of massive utilization of photovoltaic solar power, and have studied the LCOE of major countries including China, USA, Germany, Japan and Korea. Finally we have reviewed USA and Japan research programs to reduce the LCOE.

Fairness-insured Aggressive Sub-channel Allocation and Efficient Power Allocation Algorithms to Optimize the Capacity of an IEEE 802.16e OFDMA/TDD Cellular System

  • Ko, Sang-Jun;Chang, Kyung-Hi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제3권4호
    • /
    • pp.385-398
    • /
    • 2009
  • This paper aims to find a suitable solution to joint allocation of sub-channel and transmit power for multiple users in an IEEE 802.16e OFDMA/TDD cellular system. We propose the FASA (Fairness insured Aggressive Sub-channel Allocation) algorithm, which is a dynamic channel allocation algorithm that considers all of the users' channel state information conditionally in order to maximize throughput while taking into account fairness. A dynamic power allocation algorithm, i.e., an improved CHC algorithm, is also proposed in combination with the FASA algorithm. It collects the extra downlink transmit power and re-allocates it to other potential users. Simulation results show that the joint allocation scheme with the improved CHC power allocation algorithm provides an additional increase of sector throughput while simultaneously enhancing fairness. Four frames of time delay for CQI feedback and scheduling are considered. Furthermore, by addressing the difference between uplink and downlink scheduling in an IEEE 802.16e OFDMA TDD system, we can employ the uplink channel information directly via channel sounding, resulting in more accurate uplink dynamic resource allocation.

시뮬레이션을 이용한 능동형 RFID 시스템의 소비 전력 예측 (Power consumption estimation of active RFID system using simulation)

  • 이문형;이현교;임경희;이강원
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1569-1580
    • /
    • 2016
  • 2.4 GHz 능동형 RFID가 보다 활성화되기 위해 개선되어야 할 요인 중 하나는 배터리 수명 문제다. 그러나 현재 까지 소비 전력 예측을 위한 정확한 모델이 존재하지 않는다. 본 연구에서는 태그의 전력 소비를 정확하게 예측 할 수 있는 시뮬레이션 모델을 개발하였다. 충돌 제어와 query 명령어 사용 방법에 따라 6개의 시뮬레이션 모델을 제안 하였다. 예측 정확도를 높이기 위하여 태그의 작동 모드를 몇 개로 분류하고 그에 따른 전력 소비와 작동 시간을 조사하였다. 태그 수집과 응답 확인 과정을 간소화 하는 Query command 명령 방법과 최근에 제안된 충돌 제어 알고리즘을 본 시뮬레이션 모델에 사용하였다. 소비 전력 이외에도 시스템 효율과 다중 태그의 인식 시간, 그리고 인식률과 같은 성능 지표를 구하여 기존의 ISO/IEC 18000-7 시스템과 비교하였다.

Improved Routing Metrics for Energy Constrained Interconnected Devices in Low-Power and Lossy Networks

  • Hassan, Ali;Alshomrani, Saleh;Altalhi, Abdulrahman;Ahsan, Syed
    • Journal of Communications and Networks
    • /
    • 제18권3호
    • /
    • pp.327-332
    • /
    • 2016
  • The routing protocol for low-power and lossy networks (RPL) is an internet protocol based routing protocol developed and standardized by IETF in 2012 to support a wide range of applications for low-power and lossy-networks (LLNs). In LLNs consisting of resource-constrained devices, the energy consumption of battery powered sensing devices during network operations can greatly impact network lifetime. In the case of inefficient route selection, the energy depletion from even a few nodes in the network can damage network integrity and reliability by creating holes in the network. In this paper, a composite energy-aware node metric ($RER_{BDI}$) is proposed for RPL; this metric uses both the residual energy ratio (RER) of the nodes and their battery discharge index. This composite metric helps avoid overburdening power depleted network nodes during packet routing from the source towards the destination oriented directed acyclic graph root node. Additionally, an objective function is defined for RPL, which combines the node metric $RER_{BDI}$ and the expected transmission count (ETX) link quality metric; this helps to improve the overall network packet delivery ratio. The COOJA simulator is used to evaluate the performance of the proposed scheme. The simulations show encouraging results for the proposed scheme in terms of network lifetime, packet delivery ratio and energy consumption, when compared to the most popular schemes for RPL like ETX, hop-count and RER.

전력IT 고객서비스센터 운영을 통한 고객서비스 향상 방안 (Customer Satisfaction Strategy managing the Power IT Customer Service Center)

  • 정선호;최봉수;이창규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.130-132
    • /
    • 2007
  • 전력산업 구조개편이 진행된 이후 전력IT 분야에도 많은 이해관계자들이 형성되었으며, 내 외부의 많은 고객들이 형성되었다. 또한 전력시장운영과 계통운영을 위한 IT설비는 고도로 발달하여 손쉽게 이해하고 사용하기 어려울 정도로 복잡해지고 고도화 되었다. 이러한 상황에서 전력IT 분야에 대한 고객서비스를 향상 전략으로 고객과의 최접점에서 고객을 알고 고객을 지원하기 위해 전력IT 고객서비스센터를 설치하여 운영하게 되었다. 많은 예산과 인력이 투입되는 본격적인 콜센터나 서비스 데스크를 도입하기에 앞서 기존의 업무체계와 인력재배치를 통해 전력IT 분야에 대한 콜센터인 "전력IT 고객서비스센터"를 운영하여 효과적으로 고객서비스 요청에 응대하여 고객만족도 향상을 기대할 수 있을 것이며, 또한 여러 조직에서 비용과 인력을 사용하지 않고 쉽게 적용해 볼 수 있는 모델이 될 수 있을 것이다.

  • PDF