• 제목/요약/키워드: Power Generator

검색결과 3,837건 처리시간 0.025초

초전도 발전기를 갖는 전력계통의 안정도 (The Stability of Power System Including Superconducting Generator)

  • 원영진;김석환;서정윤;백영식;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1072-1074
    • /
    • 1993
  • The superconducting generator has better efficiency, larger power, higher voltage, bigger power per weight ratio and bigger power per volume ratio than conventional machines. Furthermore, for the synchronous reactance of the superconducting generator is smaller than that of conventional ones, the capacity of power transfer is much larger than conventional machina. But, the low inertia constant of superconducting generator hurts the transient stability of power system. This paper deals with the comparisons of transient characteristics between superconducting generator and conventional generator by computer simulation.

  • PDF

무인기용 직렬 하이브리드 동력시스템 운용 제어로직 (Operational Control Logic of Series Hybrid Power System for the Unmanned Aerial Vehicle)

  • 이보화;박부민;김근배
    • 한국추진공학회지
    • /
    • 제25권1호
    • /
    • pp.68-76
    • /
    • 2021
  • 본 연구에서 대상으로 삼은 직렬 하이브리드 시스템은 무인기용으로 왕복엔진, 발전기, 배터리를 주 동력원으로 사용한다. 발전기는 왕복엔진의 구동축에 직결되며, 왕복엔진-발전기 세트의 운용 특성은 지상통합시험을 통해 확인하였다. 본 연구에서는 해당 시험 결과를 바탕으로 왕복엔진-발전기 출력과 배터리 출력을 효율적으로 사용하기 위한 제어로직을 제시하였고, 로직에 따른 왕복엔진-발전기와 배터리의 출력 변동은 시뮬레이션을 통해 확인하였다. 그 결과, 발전기 출력은 제시된 제어로직에 의해 배터리 출력과 함께 추진요구전력을 공급함을 확인하였다.

500MW급 화력 발전기 냉각수 온도에 따른 고정자 권선 절연재의 흡습 특성에 관한 실험적 연구 (An Experimental Study on Water Absorbtion Characteristics of Generator Stator Bar Insulation by Cooling Water Temperature in 500MW Capacity Power Plant)

  • 배용채;김희수;이두영;이욱륜
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1392-1397
    • /
    • 2008
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. De-mineralized water is used to cool stator bars during the normal operation of generator in large power plants because the water cooled method has highest cooling efficient. Water absorption of bar insulation is progressed by several causes such as generation of water leak path by corrosion, delamination of insulation by vibration, and inadequate water treatment, etc.. Reliable water absorption diagnostics of generator stator bar is important to ensure the availability of power plant and to reduce maintenance cost by generator accident. It is described that the water absorption characteristics for generator stator bar insulation used in 500MW capacity standard fossil power plant by cooling water temperature. It is verified that the management of stator cooling water temperature is one of the important factors to decrease water absorption rate of generator stator bars.

풍력발전용 계통연계 DFIG의 출력 해석 (Power Analysis of Grid Connected Doubly Fed Induction Generator for Wind Power Generating System)

  • 이현채;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.326-329
    • /
    • 1997
  • This paper deals with the generating power analysis of wound rotor induction generator according to the rotor excitation for use of DFIG (Doubly Fed Induction Generator) system in wind power generation as a part of renewable energy development. In this way, the generating power of wound rotor induction generator can be achieved for a wide range wind speed of supersynchronous and subsynchronous speed.

  • PDF

Loss Minimization of DFIG for Wind Power Generation

  • Abo-Khalil, Ahmed G.;Park, Hong-Geuk;Lee, Dong-Choon;Lee, Se-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.315-317
    • /
    • 2007
  • This paper proposes a loss minimization algorithm for doubly-fed induction generator (DFIG) by controlling the stator reactive power. The proposed strategy directly controls the rotor current to achieve the operating point of minimum generator loss and maximum power point tracking. The maximum power is obtained by tracking the q-axis rotor current with generator speed variation and the minimum generator loss is achieved by controlling the d-axis rotor current. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

계통 연계형 권선형 유도발전기의 동작특성 연구 (Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network)

  • 김찬기;박종광;최영도;임성주;문형배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.323-326
    • /
    • 2006
  • This paper shows the comparison of operating characteristics between squirrel cage induction generator and DFIG(Double Fed Induction Generator). Because squirrel cage induction generator consume the reactive power due to magnetizing reactance, the capacitor is need to compensate the reactive power. Otherwise, two back-to-back PWM voltage-fed inverters connected between the stator and the rotor allow sub/super synchronous operation with low distortion currents. In this paper, the response characteristics of squirrel cage induction generator and DFIG, were analyzed and investigated using PSCAD/EMTDC.

  • PDF

초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구 (Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics)

  • 두진석;한승문;허창수;최진수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

Research on the Power Sharing Control and Stability of VSGs

  • Xie, Dong;Zang, Da-Jin;Gao, Peng;Wang, Jun-Jia
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.542-550
    • /
    • 2017
  • Aiming at the deficiencies of power sharing control performances when a traditional droop control is adopted for microgrid inverters, this paper proposes a microgrid inverter power sharing control strategy based on a virtual synchronous generator. This control method simulates the electromechanical transient characteristics of a synchronous generator in a power system by an ontology algorithm and the control laws of a synchronous generator by control over the speed governor and excitation regulator. As a result, that the microgrid system is able to effectively retain the stability of the voltage and frequency, and the power sharing precision of the microgrid inverter is improved. Based on an analysis of stability of a microgrid system controlled by a virtual synchronous generator, design thoughts are provided for further improvement of the power sharing precision of inverters. The simulation results shows that when the virtual synchronous generator based control strategy was adopted, the power sharing performances of microgrid inverters are improved more obviously than those using the droop control strategy.

계통 안전성을 고려한 원자력발전의 부하추종 요건연구 (A Study on Requirement of Nuclear Power Plant Load Following Operation Condition Considering Power System Security)

  • 이현철;백영식;이근준
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1565-1570
    • /
    • 2012
  • Nuclear power generation is increasing domestic power supply ratio by lower CO2 emission and fuel prices. Currently, nuclear power generator has been operated with maximum power output. Therefore, nuclear power generator could be no effect to managing the reactive power reserve on power system. The reactive power reserve is calculated to the difference between maximum facility and operation generation capacity of the power system. This paper was proposed that load following of nuclear power is control by using 15-bus power system model. In the simulation result, power system is shown to safety state by operating load following of nuclear power generator. This method has be improved the supplied reliability through economic and efficient operation.

녹색교통망을 위한 진동력 발전 기초 실험연구 (A Basic Experimental Study on Vibration Power Generator for A Green Traffic Network)

  • 조병완;이윤성;김영지;박정훈
    • 대한토목학회논문집
    • /
    • 제29권6D호
    • /
    • pp.675-683
    • /
    • 2009
  • 본 논문에서는 도로와 철도에서 자동차와 열차주행시에 발생하는 진동에너지를 건축-토목 구조물에 활용 가능한 전기에너지로 변환하는 진동력 발전시스템 인프라 구축을 위한 기초 개념에 대해 연구하였다. 본 연구에서는 자기유도기술을 활용하여 진동에너지를 전기에너지로 변환하는 진동력 발전장치를 제안하고, 자기유도기술의 기본 원리 및 진동력 발전장치의 동적특성에 대해 설명하였다. 마지막으로 외력과 진동속도에 따라 진동력 발전장치에서 발생하는 기전력의 세기와의 상관관계를 분석하기 위해 다양한 변수를 두고 실내실험을 수행하였고, 이러한 실험결과를 토대로 시험용 진동력 발전장치의 적용성과 효용성을 분석하여, 최대 가용 전력을 획득하기 위한 진동력 발전시스템의 최적설계에 대한 기초 자료를 확보하였다.