• Title/Summary/Keyword: Power Flow problem

검색결과 420건 처리시간 0.028초

전력 조류 계산의 분산 병렬처리기법에 관한 연구 (A Development of Distributed Parallel Processing algorithm for Power Flow analysis)

  • 이춘모;이해기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.134-140
    • /
    • 2001
  • Parallel processing has the potential to be cost effectively used on computationally intense power system problems. But this technology is not still available is not only parallel computer but also parallel processing scheme. Testing these algorithms to ensure accuracy, and evaluation of their performance is also an issue. Although a significant amount of parallel algorithms of power system problem have been developed in last decade, actual testing on processor architectures lies in the beginning stages. This paper presents the parallel processing algorithm to supply the base being able to treat power flow by newton's method by the distributed memory type parallel computer. This method is to assign and to compute teared blocks of sparse matrix at each parallel processors. The testing to insure accuracy of developed method have been done on serial computer by trying to simulate a parallel environment.

  • PDF

전력계통의 고장용량 억제를 위한 최적조류계산 연구 (A Study on the Optimal Power Flow with Suppressing the Short Circuit Capacity in Power Systems)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권12호
    • /
    • pp.575-580
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the ways for suppressing the short circuit capacity. This paper presents the extended optimal power flow(OPF) to the problem of selecting the T/Ls to be open. The constraints of the short circuit currents within limits are added to the inequalities of OPF. Also, the overload on the other lines due to switching of T/Ls is avoided by the linearized inequalities. The number of the open lines can be minimized by incorporating into the objective function of OPF in order to maintain reliability. The method of an effective calculation of the extended OPF is also proposed in this paper, which makes the two parts decoupled. The one concerning the generation dispatch is solved in the first place by the conventional method. Secondly, the other concerning the line-switching is optimized by the proposed formulation.

  • PDF

선형계획기반 선로혼잡처리에 대한 총송전용량 평가 (Assessment of Total Transfer Capability for Congestion Management using Linear Programming)

  • 김규호;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.447-452
    • /
    • 2006
  • This paper presents a scheme to solve the congestion problem with phase-shifting transformer(PST) controls and power generation controls using linear programming method. A good design of PST and power generation control can improve total transfer capability(TTC) in interconnected systems. This paper deals with an application of optimization technique for TTC calculation. Linear programming method is used to maximize power flow of tie line subject to security constraints such as voltage magnitude and real power flow in interconnected systems. The results are compared with that of repeat power flow(RPF) and sequential quadratic programming(SQP). The proposed method is applied to 10 machines 39 buses model systems to show its effectiveness.

전력산업 구조개편 환경 하에서 무효전력 보조서비스 운용을 위한 최적조류계산법 개발 (Development of Optimal Power Flow for the Ancillary Service of Reactive Power Generation under Restructuring Environment)

  • 송태용;정민화;이병준;남궁재용;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.58-61
    • /
    • 2001
  • Under restructuring, not only real power pricing but also reactive power pricing is important for the system operation Especially, making a reasonable reactive power pricing is becoming more important than any other time. In this paper, the authors set a proper power factor and price the portion of the reactive power generation that exceeds the power factor. To apply this method to an optimization problem, we developed optimal power flow based on interior point method. By using this IPM for the power system, the System operator can use this strategy for reactive power generation pricing and also the Generators can got the motivation to generate reactive power.

  • PDF

Analysis of Channel Flow Low During Fuelling Operation of Selected Fuel Channels at Wolsong NPP

  • I. Namgung;Lee, S.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.502-516
    • /
    • 2002
  • Wolsong NPP are CANDU6 type reactors and there are 4 CANDU6 type reactors in commercial operation. CANDU type reactors require on-power refuelling by two remote controlled F/Ms (Fuelling Machines). Most of channels, fuel bundles are float by channel coolant flow and move toward downstream, however in about 30% of channels the coolant flow are not sufficient enough to carry fuel bundles to downstream. For those channels a special device, FARE (Flow Assist Ram Extension) device, is used to create additional force to push fuel bundles. It has been showing that during fuelling operation of some channels the channel coolant flow rate is reduced below specified limit (80% of normal), and consequently trip alarm signal turns on. This phenomenon occurs on selected channels that are instrumented for the channel flow and required to use the FARE device for refuelling. Hence it is believed that the FARE device causes the problem. It is also suspected that other channels that do not use the FARE device for refuelling might also go into channel flow low state. The analysis revealed that the channel How low occurs as the FARE device is introduced into the core and disappears as the FARE device is removed from the core. This paper presented the FARE device behavior, detailed fuelling operation sequence with the FARE device and effect on channel flow low phenomena. The FARE device components design changes are also suggested, such as increasing the number or now holes in the tube and flow slots in the ring orifice.

CFD/RELAP5 coupling analysis of the ISP No. 43 boron dilution experiment

  • Ye, Linrong;Yu, Hao;Wang, Mingjun;Wang, Qianglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.97-109
    • /
    • 2022
  • Multi-dimensional coupling analysis is a research hot spot in nuclear reactor thermal hydraulic study and both the full-scale system transient response and local key three-dimensional thermal hydraulic phenomenon could be obtained simultaneously, which can achieve the balance between efficiency and accuracy in the numerical simulation of nuclear reactor. A one-dimensional to three-dimensional (1D-3D) coupling platform for the nuclear reactor multi-dimensional analysis is developed by XJTU-NuTheL (Nuclear Thermal-hydraulic Laboratory at Xi'an Jiaotong University) based on the CFD code Fluent and system code RELAP5 through the Dynamic Link Library (DLL) technology and Fluent user-defined functions (UDF). In this paper, the International Standard Problem (ISP) No. 43 is selected as the benchmark and the rapid boron dilution transient in the nuclear reactor is studied with the coupling code. The code validation is conducted first and the numerical simulation results show good agreement with the experimental data. The three-dimensional flow and temperature fields in the downcomer are analyzed in detail during the transient scenarios. The strong reverse flow is observed beneath the inlet cold leg, causing the de-borated water slug to mainly diffuse in the circumferential direction. The deviations between the experimental data and the transients predicted by the coupling code are also discussed.

진동 동력 흐름 예측 기법을 이용한 소음 전달 경로 해석 및 차량의 실내소음저감에 관한 연구 (A Study on Noise Transfer Path Analysi for Sound Improvement of Vehicle Using the Vibrational Power Flow)

  • 이상권
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.168-175
    • /
    • 2001
  • Reduction of structure-borne noise of the compartment in a car is an important task in automotive engineering. Transfer path analysis using vibroacoustic reciprocity technique or multiple path decomposition method has generally been used for structure-borne noise path analysis. These methods are useful in solving particular problem but do net quantify the effectiveness of vibration isolation of each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow has been used for a simple isolation system or a laboratory based isolation system. It is often difficult to apply the vibrational power flow technique to the complex isolation system like a car. In this paper, a simple equation is derived for calculation of the vibrational power flow of an isolation system with multiple isolators such as a car. It is successfully applied to not only quantifying the relative contributions of eighteen isolators but also reducing structure-borne noise of a passenger car. According to the results, the main contributor of eighteen isolators is the rear roll mount of an engine. The reduced structure-borne noise level is about 5dBA.

  • PDF

유연운전에 따른 석탄화력보일러 수계통 튜브에서의 이상 유동가속부식(Two-Phase Flow Accelerated Corrosion) 고찰 (A Two-Phase Flow Accelerated Corrosion Study on Water Wall Tube of Coal-Fired Boiler According to Flexible Operation)

  • 김상호;이승민;이재홍
    • Corrosion Science and Technology
    • /
    • 제23권3호
    • /
    • pp.246-254
    • /
    • 2024
  • Recently, coal-fired power plants are experiencing many problems that they have never experienced before due to an increase in flexible operation. In particular, a two-phase flow accelerated corrosion on water wall tubes in a boiler has not been detected overseas or domestically. There is no response plan to deal with such corrosion problem either. However, oxide film damage and tube material corrosion due to a two-phase flow accelerated corrosion are being discovered on water wall boiler tubes of domestic coal-fired power plants recently. If this situation is severe, it can cause enormous damage such as tube rupture. Therefore, in this paper, in order to prepare a response plan for a two-phase flow accelerated corrosion on water wall tubes in the future, differences between a two-phase flow accelerated corrosion and a single-phase flow accelerated corrosion were investigated and an example of discovery of a two-phase flow accelerated corrosion on water wall tubes was presented.

진동 파워흐름 측정을 통한 SUV용 엔진 마운트의 에너지 전달 기여도 분석에 관한 연구 (A Study on the Transmitted Energy Contribution Analysis of SUV Engine Mount by Vibration Power Flow Measurement)

  • 김수곤;이상권;김성종
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.400-410
    • /
    • 2008
  • Reduction of structure-borne noise in the compartment of a car is an important task in automotive engineering. Many methods which analyze noise transfer path have been generally used for structure-borne noise. These methods are useful in solving particular problem but do not quantify the effectiveness of vibration isolation for each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow measurement has been used for a simple isolation system or a laboratory based isolation system. This paper identifies the transfer path of booming noise in a SUV. The powertrain used for test has a in-line 4cylinder engine and 5-shift auto-transmission. This powertrain is transversely supported by four isolators. We calculated the energy flow throughout four isolator by the measurement of power flow and the contribution of energy flow at each isolator.

전력계통의 무효전력 제어 및 안전도 평가를 위한 Asynchronous Team 이론의 적용에 관한 연구 (A Study on the Application of Asynchronous Team Theory for QVC and Security Assessment in a Power System)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.67-75
    • /
    • 1997
  • This paper presents a study on the application of Asynchronous Team(A-Team) theory for QVC(Reactive power control) and security assessment in a power system. Reactive power control problem is the one of optimally establishing voltage level given reactive power sources, which is very important problem to supply the demand without interruption and needs methods to alleviate a bus voltage limit violation more quickly. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system and deterministic approach based on AC load flow calculations is adopted to assess it, especially voltage security. A distance measure, as a measurement for voltage security, is introduced. In order to analyze the above two problem, reactive power control and static security assessment, In an integrated fashion, a new organizational structure, called an A-team, is adopted. An A-team is well-suited to the development of computer-based, multi-agent systems for operation of large-scaled power systems. In order to verify the usefulness of the suggested scheme herein, modified IEEE 30 bus system is employed as a sample system. The results of a case study are also presented.

  • PDF