• Title/Summary/Keyword: Power Facility

Search Result 1,286, Processing Time 0.029 seconds

Propagation Characteristics of GIS PD Signals by Dual UHF Band Method (2)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the propagation characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, propagation characteristics of GIS PD signals were measured in the mock-up GIS bus and it was found that the propagation characteristics of the high band showed a better result in accordance with the infernal configuration of the GIS bus than those of the full band.

  • PDF

Improvement of Control Response Characteristics for Power Facility using the Adaptive Sizing of Fuzzy Inference Method (전력설비의 제어 응답특성 개선을 위한 퍼지 추론 기법의 적응조정)

  • Lee, Hyun-Jae;Kim, Dong-Eun;Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1699-1704
    • /
    • 2018
  • In this paper, proposed a method to improve of control characteristics for power facility using the adaptive sizing of fuzzy inference method. In the use of the controller based the fuzzy logic, a basic mamdani fuzzy controller is applied. However, when the maximum value and the minimum value have to taken, the fuzzy controller can not take a normal value because of formalized grouping form. In this paper, we combine the conventional methods with single valued sets to compensate for the disadvantage caused by the mamdani method control. Simulation results show that the proposed method has better overshoot and steady state arrival time than the conventional control method.

Design Methodology of Communication & Control Device for Smart Grid Power Facility based on DSP and Raspberry Pi (DSP와 라즈베리 파이를 기반으로 한 스마트 그리드 전력설비의 통신제어장치 설계 방법론)

  • Oh, Se-Young;Lee, Jun-Hyeok;Lee, Sae-In;Park, Chang-Su;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.835-844
    • /
    • 2021
  • In this paper, a power facility communication control device was designed to autonomously determine and separate the fault section through communication between power facilities in the smart grid distribution system. In the power facility communication control device, the control module was designed as a DSP to measure three-phase voltage and current, and the communication module was designed as an embedded-based Raspberry Pi to determine the fault section and realize the fault section separation through communication between power facilities. Communication between DSP and Raspberry Pi was designed by SPI communication, and communication between Raspberry Pi was designed based on Wi-Fi. Finally, a performance evaluation system based on three power facility communication control devices was built, and simulation verification was conducted for various fault events that may occur on the distribution line. As a result of the test evaluation, it was possible to confirm the effectiveness of the design methodology of the communication control device by showing the required response of the communication control device to all test cases.

Development of High Intensity Progressive Wave Tube (고에너지 음향환경시험 튜브 개발)

  • K.Kim, Young-Key;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Im, Jong-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.962-965
    • /
    • 2005
  • A high intensity progressive wave tube is installed at Korea Aerospace Research Institute (KARI) for acoustic environmental tests. The test facility has 700 mm x 800 mm cross-sectional area, and provides acoustic environment of 165 dB over the frequency range of $25Hz{\sim}10,000Hz$. The facility consists of a 6 m long acoustic wave tube, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of the facility and power generation systems are controlled to meet the requirement of the test. The shape and length of the tube has been designed by using the size of test objects and the wave propagation characteristics of the tube. The capacity of acoustic power generation systems is determined by the energy conversion of acoustic wave and the efficiency of acoustic modulators. Moreover, the paper introduces test run results of the tube. Overall of 163dB has been generated by using the test facility.

  • PDF

Radiological Environment Investigation of Radioactive Waste Disposal Facility (방사성폐기물 처분시설 주변의 방사선환경조사)

  • Baek, Jeong-Seok;Jeong, Yeui-Young;Ahn, Sang-Bok;Kim, Wan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.387-398
    • /
    • 2008
  • To obtain base-line data in the low- and intermediate-level radioactive waste disposal facility, radiological environment investigation is required at least two years prior to the facility operation near the disposal facility. The investigation has been performed since January 2007 for the Wolsong LILW disposal center. In this paper, investigation procedure and detailed information obtained for six months in 2008 are described. Based on the current results, future investigation planning is also discussed for the radiological environment management of the disposal facility.

  • PDF

Automated Maintenance Unmanned Monitoring System Using Intelligent Power Control System (지능형 전원제어장치를 이용한 자동화 유지보수 무인감시시스템)

  • Cha, Min-Uk;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.237-239
    • /
    • 2021
  • Failure and malfunction of the unmanned surveillance facility cost can lead to delays occurring until the person in charge arrives at the unmanned surveillance facility, and theft, damage, and information leakage damage caused by intruders. In addition, due to equipment failure and malfunction, additional costs are incurred due to constant inspection by the manager. In this paper, in order to compensate for the malfunction of unmanned facility costs, we propose a system that diagnoses the monitoring facility in real time, displays the contents of the problem, automatically restores the facility power, and informs the person in charge of the situation by text message. The proposed system is a surveillance facility consisting of main facilities such as video equipment (CCTV), sound equipment, floodlights, etc. And SMS server that can send text messages in real time. Through experiments, the effectiveness of the proposed system was verified.

  • PDF

Implementation of a Real-Time Data Acquisition System Based on Wireless Communication for Urban Rail Transit Substation (도시철도 변전소의 네트워크 기반 실시간 데이터 취득 시스템 구현)

  • Jung, Ho-Sung;Park, Young;Kim, Hyung-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • This paper is focused on implementing a real-time data acquisition system that checks power facility status by applying network based technology to Urban Transit substation power facilities and the results of its on-field tests. This system is composed of a sensor part, a measurement part, a transceiver part, a host computer, and a power source part. The system is designed to collect, save, analyze, and display the online state power facility AI (Analog Input). This system measures voltage and current from positive feeders and negative feeders where it is possible to check abnormalities of the substation‘s main power facilities. By monitoring abnormal data of the Urban Transit power facilities real-time and analyzing stored data, establishing procedures of optimized maintenance is possible.

Neutronic and thermohydraulic blanket analysis for hybrid fusion-fission reactor during operation

  • Sergey V. Bedenko ;Igor O. Lutsik;Vadim V. Prikhodko ;Anton A. Matyushin ;Sergey D. Polozkov ;Vladimir M. Shmakov ;Dmitry G. Modestov ;Hector Rene Vega-Carrillo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2678-2686
    • /
    • 2023
  • This work demonstrates the results of full-scale numerical experiments of a hybrid thorium-containing fuel plant operating in a state close to critical due to a controlled source of D-T neutrons. The proposed facility represented a level of generated power (~10-100 MWt) in a small pilot. In this work, the simulation of the D-T neutron plasma source operation in conjunction with the facility blanket was performed. The fission of fuel nuclei and the formation of spatial-energy release were studied in this simulation, in pulsed and stationary modes of the facility operation. The optimization results of neutronic and fluid dynamics studies to level the emerging offsets of the radial energy formed in the volume of the facility multiplying part due to the pulsed operation of the D-T neutron plasma source were presented. The results will be useful in improving the power control-based subcriticality monitoring method in coupled systems of the "pulsed neutron source-subcritical fuel assembly" type.

A Study on the Test Method of Local Information Processing Device in Digital Substation Based on IEC 61850 (IEC 61850 기반 디지털변전소 현장정보처리장치 시험 방법에 관한 연구)

  • Kim, Nam-Dae;Kim, Woo-Jung;Lee, Nam-Ho;Kim, Seok-Kon;Jang, Byung-Tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.253-257
    • /
    • 2020
  • The local information processing devices are devices that process information by converting voltage, current, and digital electric signals from legacy-type power facility into IEC 61850 based data. It acquires and processes the operation information of legacy-type power facility, performs control of power facility, and interlock function using internal logic. In particular, the time to convert data to process input and output information for a device is important because a number of protection relay input and output signals are handled by only one device. This paper introduces test methods and cases for measuring IEC 61850 communication function and input/output data conversion time of local information processing device.