• Title/Summary/Keyword: Power Detection System

Search Result 1,407, Processing Time 0.025 seconds

A Study on an Impedance Matching Technique for Rail Power Line Communication (레일 전력선통신을 위한 임피던스 정합방안 연구)

  • Seo, Ill-Kwon;Ahn, Seung-Ho;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.202-207
    • /
    • 2016
  • An auxiliary real-time train communications system among drivers, train-traffic controllers and field workers is necessary to share hazard information (i.e. rockfall detection, track maintenance) in low visibility zones (long tunnels and steep curved track). To develop the appropriate communication system, this paper proposes a new way of power line communication using the rail track (Rail - PLC), which has little noise and distortion of attenuation. Therefore, it is important to measure the impedance of the rail and to apply an impedance matching technique to increase the transmission characteristic of the Rail - PLC. This study would evaluate the reflection and the transmission characteristics of the rail using a network analyzer and an impedance matching transformer. The suitable impedance matching ratio was 1:3.28 from the result of back-to-back testing. The results confirmed that the transformer can improve the performance of the transmission signal in Rail - PLC using an impedance matching technique.

Development of Electrogastrography System (위전도 계측시스템의 개발)

  • Han, W.T.;Kim, I.Y.;Kim, W.K.;Park, K.W.;Kim, Hui-Chan;Son, J.I.;Rhee, P.L.;Rhee, J.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.403-406
    • /
    • 1997
  • Electrogastrogaphy(EGG) is the technique by which gastric myoelectrical activity is recorded noninvasively, from electrodes on the abdominal skin. Despite many attempts made over the decades, the clinical application of the EGG signal has not improved to the identification of waveform characteristics using comparison of EGG signal to be detected other EGG system. Cutaneous measurements of EGG are yet to be standardized in methods of detection and analysis. This may be responsible in part for some of the variability in the results. Thus, we develope EGG system composed of amplifiers, analysis methods, patient database or standardization. we introduce configurations of EGG system and their functions. Several important EGG parameters are introduced, including the dominant frequency and power of the EGG, the relative, period EGG-dominant frequency and power, the instability coefficient of EGG-dominant frequency and power, standard deviation, the percentage of running spectrum activity of gastric slow waves.

  • PDF

Algorithm Implementation for Detection and Tracking of Ships Using FMCW Radar (FMCW Radar를 이용한 선박 탐지 및 추적 기법 구현)

  • Hong, Dan-Bee;Yang, Chan-Su
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • This study focuses on a ship detection and tracking method using Frequency Modulated Continuous Wave (FMCW) radar used for horizontal surveillance. In general, FMCW radar can play an important role in maritime surveillance, because it has many advantages such as low warm-up time, low power consumption, and its all weather performance. In this paper, we introduce an effective method for data and signal processing of ship's detecting and tracking using the X-band radar. Ships information was extracted using an image-based processing method such as the land masking and morphological filtering with a threshold for a cycle data merged from raw data (spoke data). After that, ships was tracked using search-window that is ship's expected rectangle area in the next frame considering expected maximum speed (19 kts) and interval time (5 sec). By using this method, the tracking results for most of the moving object tracking was successful and those results were compared with AIS (Automatic Identification System) for ships position. Therefore, it can be said that the practical application of this detection and tracking method using FMCW radar improve the maritime safety as well as expand the surveillance coverage cost-effectively. Algorithm improvements are required for an enhancement of small ship detection and tracking technique in the future.

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • 송인호;최창호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute(KAERI) in Taejon to supply power with Korea Superconducting Tokamak Advanced Research(KSTAR) Neutral Beam Injection(NBI) system. NBI system requires fast cutoff of the flower supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply. There are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply. Various results taken during the commissioning phase with a 100kW resistive load and NBI source arc shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver during thefabrication and test and solutions are also presented.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

A Study on the Robust Sound Localization System Using Subband Filter Bank (서브밴드 필터 뱅크를 이용한 강인한 음원 추적시스템에 대한 연구)

  • 박규식;박재현;온승엽;오상헌
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.36-42
    • /
    • 2001
  • This paper propose new sound localization algorithm that detects the sound source bearing in a closed office environment using two microphone array. The proposed Subband CPSP (Cross Power Spectrum Phase) algorithm is a development of previously Down CPSP method using subband approach. It first split the received microphone signals into subbands and then calculates subband CPSP which result in possible source bearings. This type of algorithm, Subband CPSP, can provide more robust and reliable sound localization system because it limits the effects of environmental noise within each subband. To verify the performance of the proposed Subband CPSP algorithm, a real time simulation was conducted and it was compared with previous CPSP method. From the simulation results, the proposed Subband CPSP is superior to previous CPSP algorithm more than 5% average accuracy for sound source detection.

  • PDF

Sensorless Scheme for Interior Permanent Magnet Synchronous Motors with a Wide Speed Control Range

  • Hong, Chan-Hee;Lee, Ju;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2173-2181
    • /
    • 2016
  • Permanent magnet synchronous motors (PMSMs) have higher torque and superior output power per volume than other types of AC motors. They are commonly used for applications that require a large output power and a wide range of speed. For precise control of PMSMs, knowing the accurate position of the rotor is essential, and normally position sensors such as a resolver or an encoder are employed. On the other hand, the position sensors make the driving system expensive and unstable if the attached sensor malfunctions. Therefore, sensorless algorithms are widely researched nowadays, to reduce the cost and cope with sensor failure. This paper proposes a sensorless algorithm that can be applied to a wide range of speed. The proposed method features a robust operation at low-speed as well as high-speed ranges by employing a gain adjustment scheme and intermittent voltage pulse injection method. In the proposed scheme the position estimation gain is tuned by a closed loop manner to have stable operation in tough driving environment. The proposed algorithm is fully verified by various experiments done with a 1 kW outer rotor-type PMSM.

Operational Characteristics of the FCL Using the Mechanical Contact in the Power System (기계적 접점을 이용한 FCL의 동작 특성)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.878-882
    • /
    • 2016
  • These days, SFCLs are being developed in order to limit fault current. However, the superconducting elements that limit the fault current have such problems as capacity increase and require auxiliary devices including cooling device. If devices that comprise the current power network can withstand fault current for at least one cycle, it is possible to limit the fault current with current limiting elements by bypassing it on the fault line. In this study, the fault current limiter was configured with current transformer, vacuum interrupter, and current limiting element. Through the experience, it was confirmed that the fault current was limited within one cycle. The superconducting element, as a current limiting element, limited the fault current by 80 % within one cycle from fault occurrence, and the passive element limited it more than 95 %. Also, through the comparison between resistance curve and power consumption curve, it was confirmed that the current limiting element using a passive element was more stable than the superconducting element that required capacity increase and other auxiliary devices. It was considered that the FCL proposed in this study could limit fault current stably within one cycle from fault occurrence by using the existing power technologies such as fault current detection and solenoid valve operating circuit.

A Study on the Development of a Remote Monitoring Equipment for Ground Fault Current by Lightning Strike (낙뢰에 의한 지락전류 원격 감시장치에 관한 연구)

  • Pyo, Se Young;Kim, Tag Yong;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.783-788
    • /
    • 2020
  • Surges generated by direct strike or induction of lightning, frequent opening and closing of power system breakers, etc. cause excessive overvoltage, which can interfere with normal operation of transformers, circuit breakers, and power equipment. In order to prevent such phenomena, this study goes further from the method of establishing countermeasures by installing lightning arresters on power equipment or lines in parallel, and furthermore, remotely checking the condition of the lightning arrester and preparing immediate countermeasures when an event occurs. The purpose of the study is to prevent damage in advance.

MAC Layer Protocol for Improvement in Power Consumption and Time Delay in a Sensor Network (센서 네트워크에서 전력소모와 지연시간 개선을 위한 MAC 계층 프로토콜 연구)

  • Shin, Jae Kwan;Park, Dong Chan;Kim, Suk Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.366-368
    • /
    • 2015
  • This paper proposes a MAC protocol for sensor networks such as disaster detection system which generate the non-periodic packet. B-MAC has been used to solve delay problem for sensor networks, however, the power loss occurs due to excessive preamble and over-hearing. In contrast, S-MAC has a number of drawbacks in power consumption due to synchronization. In this paper, we propose H-MAC and analyze its performance which has improved power consumption compared to S-MAC and overhead and over-hearing compared to B-MAC.