• Title/Summary/Keyword: Power Detection System

Search Result 1,415, Processing Time 0.032 seconds

Analysis of PWM Converter for V-I Output Characteristics of Solar Cell

  • Han, Jeong-Man;Jeong, Byung-Hwan;Gho, Jae-Seok;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • Recently, photovoltaic system has been studied widely as a renewable energy system, because it does not produce environmental pollution and it has infinity energy source from the sun. A study on photovoltaic system has a lot of problems like as reappearance and repetition of some situation in the laboratory experiment for development of MPPT algorithm and islanding detection algorithm. because output characteristics of solar cell are varied by irradiation and surface temperature of solar cell. Therefore, the assistant equipment which emulates the solar cell characteristics which can be controlled arbitrarily by researcher is require to the researchers for reliable experimental data. In this paper, the virtual implement of solar cell (VISC) system is proposed to solve these problems and to achieve reliable experimental result on photovoltaic system. VISC system emulates the solar cell output characteristics, and this system can substitute solar cell in laboratory experiment system. To realize the VISC, mathematical model of solar cell is studied for driving converter and the DC/DC converters are compared in viewpoint of tracking error using computer simulation. Output dynamic characteristic of PV array is varied by irradiation and PWM converter performance is studied using PSIM simulator.

Power Transmission Line Hazardous Material Surveillance System Implemented Laser Scanning (레이저를 이용한 송전선 위해물질 감지시스템)

  • Park, Gang-Sook;Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.95-103
    • /
    • 2012
  • In this paper, we implemented a surveillance system for the power transmission line protection from heavy-duty fender-bender. Laser scanning technology was applied for system design. It was analyzed detailed functions for designed system. Measured detection rate and error rate that are monitoring parameters for both studied system and conventional system were 100%, 0% and 95.8%, 2.1%, respectively. Measurement showed that studied system is almost perfect and better than conventional system. Because this system provides the information to frontline workers with managers of heavy equipments that have possibility of accident, it can be applied to surveillance system for the transmission line protection.

Autonomous Navigation System of Power Wheelchair using Distance Measurement Sensors (거리측정센서를 이용한 자동주행 전동 휠체어 시스템)

  • Lee, Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.3
    • /
    • pp.174-182
    • /
    • 2013
  • The power wheelchair is an important and convenient mobility device. The demand of power wheelchair is increasing for assistance in mobility. In this paper we proposed a robotic wheelchair for mobility aid to reduce the burden from the disabled. The main issue in an autonomous wheelchair is the automatic detection and avoidance of obstacles and going to the pre-designated place. The proposed algorithm detects the obstacles and avoids them to drive the wheelchair to the desired place safely with panning scan from sensors of distance measurement and fuzzy control. By this way, the disabled will not always have to worry about paying deep attention to the surroundings and his path.

A Power Quality Monitoring system using wavelet based RBF network (웨이블릿 기반의 RBF 신경망을 이용한 전력품질 진단시스템)

  • Kim Hong kyun;Lee Jinmok;Choi Jeaho;Lee Sanghoon;Kim Jaesig
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.858-861
    • /
    • 2004
  • This paper presents a wavelet-based neural network technology for the detection and classification of the various types of power quality disturbances. Power quality phenomena are short-time problems and of many varieties. Particularly, the transients happen during very short durations to the nano- and microsecond. Thus, a method for detecting and classifying transient signals at the same time and in an automatic combines the properties of the wavelet transform and the advantages of neural networks. Especially, the additional feature extraction to improve the recognition rate is considered. The configuration of the hardware of WN (PQ-DAS) and some case studies are described.

  • PDF

Introduction to Interferometer-based local lighting detection system (근거리 낙뢰관측을 위한 간섭계방식의 측정시스템 구축)

  • Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Shim, E.B.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.727-729
    • /
    • 2005
  • 본 논문에서는 낙뢰에서 발생하는 VHF 대역의 신호를 광대역 간섭계를 통하여 낙뢰의 방전경고 측정하는 거리 낙뢰관측 시스템을 소개하고자 한다. 측정시스템은 3개의 광대역 전계센서와 LF/VLF 대역의 전계센서로 구성된다. 측정된 신호는 잡음 제거를 위한 필터를 거쳐 디지털 신호로 변환되어 메모리에 저장되어 진다. 각각의 센서로부터 측정된 신호는 FFT분석을 거쳐 신호원인 낙뢰의 방위각과 고도각이 계산되어진다. 이 시스템은 30 km 내외의 뇌운의 방전 경로의 형성과 진전과정을 세밀하게 관측할 수 있다.

  • PDF

A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer (가스분석을 이용한 전력용 변압기 이상진단 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

Harmonic and Interhamonic Detection and Estimation of Power Signal using Subband MUSIC/ESPRIT (부밴드 MUSIC/ESPRIT를 이용한 전력신호 고조파 및 중간고조파 검출 및 추정)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.149-158
    • /
    • 2015
  • This paper proposes a subband filtering technique to the MUSIC and the ESPRIT algorithm for estimating the magnitude and frequency of the harmonics of power signal. In proposed method, the input power signal is decomposed to the odd harmonics and the even harmonics respectively by the filter bank system. The amplitude and the frequency estimation of the decomposed harmonics are carried out using the MUSIC and the ESPRIT method. Subband filtering can reduce the autocorrelation matrix size of input data, and spectrum leakage between adjacent harmonics. Therefore, this subband technique has advantage in computational cost and estimation accuracy compared to fullband MUSIC and ESPRIT. To demonstrate the performance of the method, computer simulations are performed to the synthesized input signal, and experiment results are compared in subband and fullband cases.

Fault Location Diagnosis of Photovoltaic Power Arrays (태양광 어레이의 고장 위치 진단 기법)

  • Lee, Sang Jun;Lee, Roo Da;Cho, Hyun Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.81-82
    • /
    • 2015
  • Recently, fault detection and diagnosis techniques have been significantly considered to reduce possible economic loss due to faulty in photovoltaic power systems. This paper presents a new fault location diagnosis method for photovoltaic power systems. The proposed algorithm compares the output voltage generated from a photovoltaic array to the outputs of its neighboring arrays. This concept is realized by obtaining error voltages among all arrays, which are simply defined by deviation between its neighboring arrays. We accomplish a real-time experiment to demonstrate reliability of the proposed fault location diagnosis by using a 60W photovoltaic power system test-bed.

  • PDF

Power Monitoring and Distributed Control by Digital Relay (디지털 계전기를 이용한 전력감시 및 분산제어)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.263-266
    • /
    • 2001
  • In this paper, intelligent methods using digital protection relay in power SCADA system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. The test result on the basis of KEMC 1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Power Control in Uplink and Downlink CDMA Systems with Multiple Flow Types

  • Li Yun;Ephremides Anthony
    • Journal of Communications and Networks
    • /
    • v.8 no.3
    • /
    • pp.313-322
    • /
    • 2006
  • We consider a power controlled code division multiple access (CDMA) system with multiple flow types. At each of the N nodes, there are F flow types with different signal-to-interference-and-noise-ratio (SINR) requirements. To keep the complexity of the transmitter low, we assume that each node uses the same power level for all its flows. The single flow case has been fully solved and is well-understood. We concentrate on the multiple flow case, and use a novel and different approach. For the uplink problem with N = 2 and F arbitrary, the necessary and sufficient conditions to have a solution are found and proved. For the general N > 1 uplink problem, we provide a necessary condition for the problem to have a solution and an iterative algorithm to find the optimum solution. For the downlink case with F > 1 some properties of the optimal sequences are obtained.