• Title/Summary/Keyword: Power Detection System

Search Result 1,415, Processing Time 0.034 seconds

A study on the SIC of using group separation in CDMA system (CDMA 시스템에서 그룹분리를 이용한 순차적 간섭 제거기에 관한 연구)

  • 최병구;이영철;염순진;박용완
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.130-134
    • /
    • 1999
  • In this paper, we introduce a modified interference cancellation scheme for multiuser detection in CDMA. This detector uses successive interference canceller(SIC) and the divided received signal concepts. The active users are splits into two groups large signal power group and small signal power group- throughout ranking, matched filter, decision, regeneration. And each group is subtracted from the received signal respectively to obtain good BER performance. Each of the resulting signal is become respectively SICs input signal The computer simulation and analysis of structure demonstrate that the proposed SIC keeps the SICs BER performance, complexity and reduces SICs delay time.

  • PDF

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

Localization and size estimation for breaks in nuclear power plants

  • Lin, Ting-Han;Chen, Ching;Wu, Shun-Chi;Wang, Te-Chuan;Ferng, Yuh-Ming
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.193-206
    • /
    • 2022
  • Several algorithms for nuclear power plant (NPP) break event detection, isolation, localization, and size estimation are proposed. A break event can be promptly detected and isolated after its occurrence by simultaneously monitoring changes in the sensing readings and by employing an interquartile range-based isolation scheme. By considering the multi-sensor data block of a break to be rank-one, it can be located as the position whose lead field vector is most orthogonal to the noise subspace of that data block using the Multiple Signal Classification (MUSIC) algorithm. Owing to the flexibility of deep neural networks in selecting the best regression model for the available data, we can estimate the break size using multiple-sensor recordings of the break regardless of the sensor types. The efficacy of the proposed algorithms was evaluated using the data generated by Maanshan NPP simulator. The experimental results demonstrated that the MUSIC method could distinguish two near breaks. However, if the two breaks were close and of small sizes, the MUSIC method might wrongly locate them. The break sizes estimated by the proposed deep learning model were close to their actual values, but relative errors of more than 8% were seen while estimating small breaks' sizes.

Design and Implementation of Microstrip Quadrature Coupler and High Power Transmitting/Receiving Switch Using Dynamic Loading Technique for 1-Tesal MRI System (동적 부하 기술을 이용한 1-Tesla 자기공명 영상 시스템용 마이크로 스트립 quadrature coupler 및 고출력 송수신 스위치의 설계 및 제작)

  • 류웅환;이미영;이흥규;이황수;김정호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.1-11
    • /
    • 1999
  • It is now common practice to utilize the quadrature RF coils to improve the signal-to-noise ratio (SNR) in the Magnetic Resonance Imaging (MRI) System. In addition, to make such an available SNR improvement, it is mandatory to use a well-designed quadrature coupler, which facilitates a perfect 3-dB coupling and quadrature-phase shift. However, the four ports matching condition has to be well considered during the RF excitation and the signal detection period. This work investigates the effects of such a mismatching condition (especially, due to patient) from the analysis, simulation, and real implementation and firstly proposes dynamic loading technique for a quadrature coupler and transmitting/receiving switch module to minimize a patient mismatching and enhance a system reliability. Also, we designed and implemented the quadrature coupler and transmitting/receiving switch module using microstrip. As a result, the SNR of our MRI system using the microstrip quadrature coupler and transmitting/receiving switch module with dynamic load increases 3 dB compared with the old one using USA quadrature switch. Also, the power capability of quadrature coupler and transmitting/receiving switch module is 5-kw peak power. Considering power loss and reduction of size, we used a RT/duroid 6010 substrate with high permittivity and for simulation we use Compact Software.

  • PDF

A Study on SCOTT Transformer Protection Relay Malfunction Case and Improvement Methodology (스코트 변압기 보호계전기 오동작 사례분석 및 개선방안 고찰)

  • Lee, Jong-Hwa;Lho, Young-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.394-399
    • /
    • 2017
  • In Korean AC power railway substations, SCOTT winding transformers are under operation to have a single phase power supply together with a phase angle of $90^{\circ}$ on the secondary side of the main transformer. In the case of an internal fault of the transformer, the transformer protection relay should be cut off on the primary side, the transformer should be inoperative to the external fault of the transformer or to the normal train operation. Reducing the malfunction of the relay through an exact fault determination is very important for securing a stable power system and improving its reliability. The main transformers are protected using Buchholtz's relay and a differential relay as the internal fault detection devices, but there are some cases of the main transformer operation under the deactivation of this protection function due to a malfunction of the differential relay. In this paper, the characteristics of the SCOTT transformer and differential relay as well as the malfunctioning of the protection relays are presented. The modeling of the SCOTT transformer protection relay was accomplished by the power system analysis program and the Comtrade file from 'A substation', which was used as the input data for the fault wave, and the harmonics were analyzed to determine if the relay operates or not. In addition, an improvement plan for malfunctioning cases through wave form analysis is suggested.

Characteristics of the Fault Current and the Protection for Superconducting and Normal Conducting Limiter combined with a Transformer (상용변압기와 결합된 초전도체 및 상전도체 한류기의 고장전류 및 보호기기 동작특성)

  • Im, In-Gyu;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1313-1317
    • /
    • 2013
  • With increasing demand of power, the equipment of power system is enlarging and the absolute capacity is going up. As a result, when a fault occurs, the fault current is consistently increasing. Therefore, I suggested some solution for limiting the fault current more efficiently. This study shows the characteristics of superconducting limiting elements and normal conducting elements combined with a transformer. We performed a short-circuit test about the fault current by using SCR switching control system operated from a CT. When short circuit accidents happened in the secondary side of a transformer, fault currents flowed and a SCR switching control system was operated. It resulted in a decrease of the fault current in the limited elements of third winding connected in parallel. For this test, we used YBCO thin films and normal conducting elements as the limited elements. Within a cycle, a superconducting fault current limiter with YBCO thin films reduced more than 90% of fault current because the resistance of superconducting elements sustainedly grew. On the other hand, the limiter with normal conductors limited as much as a set value because its resistance characteristic was linear. Consequently, in case of the limiter with superconductor, limiting range of the circuit was wide but the range of protective detection was undefined. In contrast, as for the limiter with normal conductors, limiting range and protection duty were appropriate.

Null Allele in the D18S51 Locus Responsible for False Homozygosities and Discrepancies in Forensic STR Analysis

  • Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.17 no.2
    • /
    • pp.151-155
    • /
    • 2011
  • Short tandem repeats (STRs) loci are the genetic markers used for forensic human identity test. With multiplex polymerase chain reaction (PCR) assays, STRs are examined and measured PCR product length relative to sequenced allelic ladders. In the repeat region and the flanking region of the commonly-used STR may have DNA sequence variation. A mismatch due to sequence variation in the DNA template may cause allele drop-out (i.e., a "null" or "silent" allele) when it falls within PCR primer binding sites. The STR markers were co-amplified in a single reaction by using commercial PowerPlex$^{(R)}$ 16 system and AmpFlSTR$^{(R)}$ Identifiler$^{(R)}$ PCR amplification kits. Separation of the PCR products and fluorescence detection were performed by ABI PRISM$^{(R)}$ 3100 Genetic Analyzer with capillary electrophoresis. The GeneMapper$^{TM}$ ID software were used for size calling and analysis of STR profiles. Here, this study described a forensic human identity test in which allelic drop-out occurred in the STR system D18S51. During the course of human identity test, two samples with a homozygous (16, 16 and 21, 21) genotype at D18S51 locus were discovered using the PowerPlex$^{(R)}$ 16 system. The loss of alleles was confirmed when the samples were amplified using AmpFlSTR$^{(R)}$ Identifiler$^{(R)}$ PCR amplification kit and resulted in a heterozygous (16, 20 and 20, 21) genotype at this locus each other. This discrepancy results suggest that appropriate measures should be taken for database comparisons and that allele should be further investigated by sequence analysis and be reported to the forensic community.

Development of Variable Speed Digital Control System for SRM using Simple Position Detector (간단한 위치검출기를 이용한 SRM 가변속 디지털 제어시스템 개발)

  • 천동진;정도영;이상호;이봉섭;박영록
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.202-208
    • /
    • 2001
  • A Switched Reluctance Motor(SRM) has double salient poles structure and the phase windings are wound in stator. SRM hase more simple structure that of other motor, thus manufacture cost is low, mechanically strong, reliable to a poor environment such as high temperature, and maintenance cost is low because of brushless. SRM needs position detector to get rotator position information for phase excitation and tachometer or encoder for constant speed operation. But, this paper doesn\`s use an encoder of high cost for velocity measurement of rotator. Instead of it, the algorithm for position detection and velocity estimation from simple slotted disk has been proposed and developed. To implement variable speed digital control system with velocity estimation algorithm, the TMS320F240-20MIPS fixed point arithmetic processor of TI corporation is used. The experimental results of the developing system are enable to control speed with wide range, not only single pulse, hard chopping mode and soft chopping, ut also variable speed control, and advance angle control.

  • PDF