• 제목/요약/키워드: Power Detection System

검색결과 1,409건 처리시간 0.029초

초전도 Power Supply의 전류펌핑 과정에서 발생하는 조기 퀜치발생 진단 (A study on the Detection of Premature Quench Generated in the Process of Current Pumping in a Superconducting Power Supply)

  • 김호민;배준한;노정섭;심기덕;장원갑;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 1997
  • This paper is to analyze the Premature Quench characteristics of a rotating magnet type superconducting fluxpump and consider the method of detecting and protecting this premature quench. Practically, there is contact resistance between the fluxpump and the load, namely the S.C. magnet. The thermal increase due to the contact resistance cause the premature quench before the charging current amounts to the critical current of S.C magnet. Therefore, this paper is devoted to solving the heat equation on contact region using cylindrical coordinates and to calculating the rate of thermal increase during the current is pumped up. Doing so, the predictive value of the maximum pumping current is obtained. It has been verified that the results of simulation are coincident with those of experiment. It must be considered essentially to minimize the contact resistance in designing the S.C fluxpump system in order to protect the premature quench and improve the maximum pumping current.

  • PDF

OFDM 방식의 수신기를 위한 보간기의 효율적인 심볼 동기방법의 성능분석 (An Efficient symbol Synchronization Scheme with an Interpolator for Receiving in OFDM)

  • 김동옥;윤종호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.574-577
    • /
    • 2002
  • 본 논문에서는 보간 방식을 사용하는 OFDM 전송방식 통신 시스템에 적합한 새로운 심볼 시간동기 처리 방법 제시한다. 제안된 방법은 다음과 같은 과정을 거친다. 먼저, 수신되는 포락선 신호의 평균 전력을 연속적으로 측정함으로서, 대략적인 심볼 시간동기절차를 수행한다. 이 절차에 의해, 동기가능여부에 대한 판정을 한다. 만약 동기가 가능하다고 판단되는 경우, 이어서, 짧은 길이의 훈련신호와 수신된 포락선신호간의 상관성을 측정하는 방법을 사용하여, 정확한 심볼 동기과정을 수행하도록 한다. 마지막으로, 긴 훈련 신호를 사용한 주파수 동기절차를 수행하도록 하는데, 이것은 심볼 시간 동기 과정에서 발생되는 미세한 심볼 동기 오차에 의한 성상도의 회전 효과를 교정 할 수 있도록 하기 위함이다. 시뮬레이션 결과로부터, 제안된 동기방법이 주파수 선택적 페이딩 채널 하에서도 우수한 동기특성을 제공함을 알 수 있다.

  • PDF

Management of Neighbor Cell Lists and Physical Cell Identifiers in Self-Organizing Heterogeneous Networks

  • Lim, Jae-Chan;Hong, Dae-Hyoung
    • Journal of Communications and Networks
    • /
    • 제13권4호
    • /
    • pp.367-376
    • /
    • 2011
  • In this paper, we propose self-organizing schemes for the initial configuration of the neighbor cell list (NCL), maintenance of the NCL, and physical cell identifier (PCI) allocation in heterogeneous networks such as long term evolution systems where lower transmission power nodes are additionally deployed in macrocell networks. Accurate NCL maintenance is required for efficient PCI allocation and for avoiding handover delay and redundantly increased system overhead. Proposed self-organizing schemes for the initial NCL configuration and PCI allocation are based on evolved universal terrestrial radio access network NodeB (eNB) scanning that measures reference signal to interference and noise ratio and reference symbol received power, respectively, transmitted from adjacent eNBs. On the other hand, the maintenance of the NCL is managed by adding or removing cells based on periodic user equipment measurements. We provide performance analysis of the proposed schemes under various scenarios in the respects of NCL detection probability, NCL false alarm rate, handover delay area ratio, PCI conflict ratio, etc.

CDMA 시스템에서 그룹분리를 이용한 순차적 간섭 제거기에 관한 연구 (A study on the SIC of using group separation in CDMA system)

  • 최병구;이영철;염순진;박용완
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 추계종합학술대회
    • /
    • pp.130-134
    • /
    • 1999
  • 본 논문에서는 CDMA 시스템에서 다중 사용자 검출을 위해 수신신호를 나누는 개념과 순차적 간섭 제거기를 조합한 새로운 간섭 제거기를 제안한다. 본 간섭 제거기에서 수신신호는 큰 신호 성분들의 그룹, 작은 신호 성분들의 그룹으로 나눠지며 각 그룹의 신호들은 재 확산되어 각각 수신신호에서 제거되고 그 결과치는 원하는 신호 검출을 위해 각각 위, 아랫단 순차적 간섭 제거기의 입력 신호로 이용된다. 컴퓨터 시뮬레이션 및 구조분석을 통해서 향상된 순차적 간섭 제거기가 비트 오율과 복잡성의 면에서 순차적 간섭 제거기의 성능을 유지시키는 동시에 순차적 간섭 제거기의 지연시간에 대한 단점을 향상시킴을 보여준다.

  • PDF

모의 변압기의 VHF/UHF PD 스펙트럼 분석 (Spectrum Analysis of VHF/UHF PD in Simulated Transformer)

  • 김덕근;김종서;임용배;임장섭;문채주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구 (A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD))

  • 김지홍;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

유도초음파를 이용한 3/4″ 배관 결함 검출 연구 (A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave)

  • 정우근;김진회;천근영
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

Localization and size estimation for breaks in nuclear power plants

  • Lin, Ting-Han;Chen, Ching;Wu, Shun-Chi;Wang, Te-Chuan;Ferng, Yuh-Ming
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.193-206
    • /
    • 2022
  • Several algorithms for nuclear power plant (NPP) break event detection, isolation, localization, and size estimation are proposed. A break event can be promptly detected and isolated after its occurrence by simultaneously monitoring changes in the sensing readings and by employing an interquartile range-based isolation scheme. By considering the multi-sensor data block of a break to be rank-one, it can be located as the position whose lead field vector is most orthogonal to the noise subspace of that data block using the Multiple Signal Classification (MUSIC) algorithm. Owing to the flexibility of deep neural networks in selecting the best regression model for the available data, we can estimate the break size using multiple-sensor recordings of the break regardless of the sensor types. The efficacy of the proposed algorithms was evaluated using the data generated by Maanshan NPP simulator. The experimental results demonstrated that the MUSIC method could distinguish two near breaks. However, if the two breaks were close and of small sizes, the MUSIC method might wrongly locate them. The break sizes estimated by the proposed deep learning model were close to their actual values, but relative errors of more than 8% were seen while estimating small breaks' sizes.

3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구 (A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor)

  • 최신형;곽동걸;김진환
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.61-67
    • /
    • 2012
  • 3상 전동기를 이용하는 3상 전력계통에서 1상이 결상되면 계통에는 불평형 전류가 흐르거나 단상전력이 공급되어 전동기 코일의 과전류로 인한 화재발생은 물론 전력계통에 큰 피해를 주게 된다. 최근 3상 전동기 결상검출 방식으로는 열동 과전류계전기와 전자식 모터 보호계전기가 대다수 이용되고 있으며, 이들은 선로의 과열이나 과전류가 발생되면 검출하고 차단기를 동작시키는 방식으로 감지속도가 느리고 오동작과 정밀도가 떨어지는 문제점이 있다. 이들을 개선하기위하여 본 논문에서는 반도체 소자를 이용한 새로운 결상보호용 제어회로 토폴로지를 설계하여 감지속도와 정밀도를 향상시키고, 소형 경량으로 제작되어 현장의 3상 전동기 제어반에 용이하게 장착시킬 수 있는 장점이 있다. 그 결과 제안한 결상 보호장치는 3상 전동기를 보호하고 결상으로 발생하는 전기화재를 최소화시키고 그리고 전력계통의 안정적인 운전에 기여할 수 있을 것이다. 제안한 결상 보호장치는 다양한 동작특성 실험을 통하여 그 성능과 신뢰성이 입증된다.

원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템 (Doppler Radar System for Long Range Detection of Respiration and Heart Rate)

  • 이지훈;김기범;박성욱
    • 한국전자파학회논문지
    • /
    • 제25권4호
    • /
    • pp.418-425
    • /
    • 2014
  • 본 논문에서는 원거리에서 사람의 호흡 및 심박수를 측정할 수 있는 Ku-Band 대역의 도플러 레이더 시스템을 설계하였다. 레이더로 측정을 하는 동시에 ECG(Electrocardiogram)를 이용하여 호흡 및 심박수 측정을 하였다. 수신된 I/Q(Inphase & Quadrature-phase) 신호를 이용한 arctangent demodulation을 적용하였을 때 RMSE(Root Mean Square Error)값을 약 50 % 정도 개선시킬 수 있었다. CW(Continuous Wave) 도플러 레이더는 송수신단이 연속적으로 항상 열려 있기 때문에 송신안테나에서 수신 안테나로 누설되는 전력이 발생하게 된다. 출력 파워가 높아질수록 누설되는 전력은 시스템의 SNR(Signal-to-Noise Ratio)에 영향을 주게 된다. 따라서 본 연구에서는 원거리에서 감지가 가능하도록 누설 전력의 반대위상을 갖는 신호를 더해줌으로써 누설 전력으로 인한 수신단의 감도 저하를 최소화 시키는 기법을 적용하였다. 위의 leakage cancellation 기법을 적용하여 최대 35 m 거리 대상의 호흡 및 심박 수를 측정하였으며, 이와 비교하여 ECG 값에서 추출한 심박 수 값과 일치함을 볼 수 있다.