• Title/Summary/Keyword: Power Converter

Search Result 6,241, Processing Time 0.031 seconds

A Study on the Telemetric Measuring System of the Underwater Information (수중정보의 원격계측시스템에 관한 연구)

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.7-11
    • /
    • 1988
  • This Paper describes technique for the design of system for telemetering the water temperature at sea. This telemetering device adopts FM-FM system, and its main carrier wave is 146.2MHz. The transmission power is about 1W, and the available distance of transmission is 2km. The telemetering time for the transmission and pause is controlled automatically by the CMOS programmable timer. The water temperature is measured by the electronic thermometer, it is varied by V-F converter which is built to a linear voltage controlled oscillator. The results of the experiment at the place where the receiver is off 2km from the transmitter, the water temperature measured with the mercury thermometer well agree with that of the telemetering device.

  • PDF

Grid faults characteristics simulation of inverter-fed induction generator (인버터 부착형 농형 유도발전기의 계통고장특성 모의)

  • Hong, Jitae;Kwon, Soonman;Kim, Chunkyung;Lee, Jongmoo;Cheon, Jongmin;Kim, Hong-Ju;Kim, Heeje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF

New Multi-pulse Rectifier Systems Using An Open-Delta Auto-Connected Transformer (개방-델타 단권선 변압기를 이용한 새로운 다중 펄스 정류기 시스템)

  • Gang, Mun-Sik;U, Byeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.5
    • /
    • pp.278-285
    • /
    • 1999
  • This paper proposes new 12 and 24-pulse rectifier systems using an open-delta auto-connected transformer. This approach employs two static converters to operate it at higher than utility line frequencies and to provide multi-pulse operation. By operating magnetic components at a higher frequency, higher power density can be achieved. A unique feature of the proposed approach is that the magnetic components for the dc-side are also exposed to a higher frequency and these components too are reduced in size. The switching frequency and its harmonic components are absent in the utility input line current. The VA ratings of the transformer and static converter are 0.236/0.292 [pu] and 0.11/0.18 [pu] in 12 and 24-pulse rectifier system, respectively. A finer grade of steel or alternatives can be deployed to increase performance and reduce size further. Analysis, simulations, simulations, design example, and experimental results for a 480[V], 10{kVA] prototype system are presented.

  • PDF

Determination of Optimal sizes of Battery Energy Storage System Considering Rate-Of-Return for Customers-side (수익률을 고려한 수용가측 전자전력저장시스템의 최적용량 선정)

  • Hong, Jong-Seok;Kim, Jae-Chul;Choi, Joon-Ho;Son, Hak-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.146-148
    • /
    • 2001
  • This paper discusses the optimal sizes of BESS. The goal must be optimized electricity charge of the customers-side with choosing the time-of-use rates. Therefore the cost is minimized by BESS installed the customers-side. Feasible ROR that means the ratio of capital costs to economic effect owned the optimal BESS sizes is determined the suitable domestic condition based on the battery cost and power converter system cost. Payback period times can be presented by BESS through the ROR. Multi-Pass Dynamic Programming(MPDP) algorithm is applied to the customer for the optimal sizes determination in this paper. It is to solve the optimal solution under the constraints. To investigate the efficiencies of the constraints, it is applied the typical load curve to the high-voltage customer owned Time-Of-Use(TOU) whether BESS is installed or not. Well, The result is obtained that feasible BESS sizes can be achieved the suitable customers-side of meter through the ROR.

  • PDF

Development of the 3kW Class Low Cost Fuel Inverter System for Residential Power Generation - DC-DC Converter Design and Control for Fuel Cell System (3kW급 주택용에 사용되는 저가의 연료전지용 인버터 시스템 - 연료전지 시스템용 DC-DC 컨버터 설계 및 제어)

  • Lee, S.H.;Cho, M.C.;Hwang, G.D.;Mun, S.P.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1161-1162
    • /
    • 2006
  • 본 논문은 3[kW]급 연료전지와 연료전지의 저전압$[40{\sim}60[Vdc]$)을 승압(380vdc)하기 위한 풀-브리지 DC-DC 컨버터, 그리고 승압된 링크전압을 교류 상용전압(220[Vac], 60[Hz)으로 변환하기위한 단상 풀-브리지 인버터로 구성된 연료전지 발전용 전력변환시스템 중 연료전지 시스템용 DC-DC 컨버터를 제안하였다. 제안한 연료전지 시스템용 DC-DC 컨버터는 변압기 2차측에 배전류 정류회로를 삽입하여 기존의 고주파 변압기 보다 간단하면서 무게 및 부피를 줄였다. 그리고 위상 천이 PWM 제어로 출력 전압을 가변시켜 영전압 스위칭을 달성 함으로써 스위칭 손실을 줄였으며. 효율을 95%이상 달성 하였다.

  • PDF

Development of 500W Inverter with Pure Sine Wave Output (500W급 순수사인파 인버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • This paper is elaborates on the pure sine wave single phase inverter of 500W level which is driven by battery. The inverter is structured to raise the battery voltage to 400V by using the push-pull topology, and by using H-bridge with the high voltage, it outputs common 220VAC. This topology is utilized to use the power semiconductor device in order to design and manufacture the inverter of 500W at input voltage rating of 12VDC. As a result, the efficiency exceeds 90% in partial sections, but on average, the efficiency is approximately 89.5%, and as for output voltage, frequency fluctuation range and THD, the result can be less than ${\pm}5%$.

EMC Tests for CTU EQM of GEO Communication Satellite (정지궤도 통신위성의 원격측정명령처리기 성능검증모델 전자파환경시험)

  • Koo, Ja-Chun;Choi, Jae-Dong;Kim, Joong-Pyo;Koo, Cheol-Hea;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.100-109
    • /
    • 2005
  • This paper introduce electromagnetic environmental requirements, test procedures and test results for the Command Telemetry Unit(CTU), which is engineering qualification model for communication satellite in geostationary earth orbit. Also, through debugging of the CTU during the Electro Magnetic Compatibility(EMC) tests, this paper evaluates characteristics of noise generated by the CTU. It is also obtained that better EMC performance can be acquired by improving electrical power converter module of the CTU.

Development of Wound Rotor Synchronous Motor for Belt-Driven e-Assist System

  • Lee, Geun-Ho;Lee, Heon-Hyeong;Wang, Qi
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.487-493
    • /
    • 2013
  • The automotive industry is showing widespread interest in belt-driven electric motor-assisted (e-Assist) systems. A belt-driven assist system (BAS) starts and assists the combustion engine in place of the conventional generator. In this study, a water-cooled wound rotor synchronous motor (WRSM) for the e-Assist system was designed and analyzed. The performance of the WRSM was compared with that of an interior permanent magnet synchronous motor (IPMSM). The WRSM efficiency can be improved for the BAS by adjusting the field flux at high speeds. The field current map to obtain the maximum efficiency based on the speed and torque was developed. To control the field flux via field current control in the WRSM, a general H-bridge circuit was added to the WRSM inverter to get the rapid current response in the high-speed region; the characteristics were compared with the chopper circuit. A WRSM developed for the belt-driven e-Assist system and a prototype 115 V power electronic converter to drive the WRSM were tested with a 900 cc combustion engine. The test results showed that the WRSM-type e-Assist system had good characteristics and could successfully start and assist the 900 cc combustion engine.

An I-V Circuit with Combined Compensation for Infrared Receiver Chip

  • Tian, Lei;Li, Qin-qin;Chang, Shu-juan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.875-880
    • /
    • 2018
  • This paper proposes a novel combined compensation structure in the infrared receiver chip. For the infrared communication chip, the current-voltage (I-V) convert circuit is crucial and important. The circuit is composed by the transimpedance amplifier (TIA) and the combined compensation structures. The TIA converts the incited photons into photocurrent. In order to amplify the photocurrent and avoid the saturation, the TIA uses the combined compensation circuit. This novel compensation structure has the low frequency compensation and high frequency compensation circuit. The low frequency compensation circuit rejects the low frequency photocurrent in the ambient light preventing the saturation. The high frequency compensation circuit raises the high frequency input impedance preserving the sensitivity to the signal of interest. This circuit was implemented in a $0.6{\mu}m$ BiCMOS process. Simulation of the proposed circuit is carried out in the Cadence software, with the 3V power supply, it achieves a low frequency photocurrent rejection and the gain keeps 109dB ranging from 10nA to $300{\mu}A$. The test result fits the simulation and all the results exploit the validity of the circuit.

THE NEW THICK-FILM HYBRID CONVERTERS FOR HALOGEN AND FLUORESCENT LAMPS

  • Gondek, J.;Dzialek, K.;Kocol, J.;Kawa, B.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.04a
    • /
    • pp.57-65
    • /
    • 2001
  • Economical consumption of energy, longer life of lamps, higher lighting comfort and new aesthetic of illumination is subject of numerous research and development works. The halogen lamps are an example of positive solution some of above mentioned problems. The electronic transformers are more frequent used for their supply. In comparison with conventional transformers they have less weight, less volume and 60% less power tosses. Their advantages are particular visible, when the hybrid technique is applied. The paper presents the results of engineering research and development works carried out ill Private Institute of Electronic Engineering, in R. & D. Center for Hybrid Microelectronics and Resistors and in Technical School of Communications in Krakow, in the field of the design and exploitation tests of hybrid converters 220V AC /12V DC (electronic transformers) and electronic ballasts destined for the supply of halogen lamps 20W to 150W and fluorescent lamps respectively. To perform the converters, thick film technology and surface mount technology were used. For the protection of converter electronic circuit the thick film temperature sensor and transistors were applied. Moreover the paper presents the base application circuits of elaborated converters, their technical parameters and exploitation results. The development perspectives of hybrid domain of hybrid circuits are also discussed.

  • PDF