• Title/Summary/Keyword: Power Control Error

Search Result 1,077, Processing Time 0.046 seconds

Performance Evaluation of Reverse Link for Speech and Data Traffic ini CDMA-Based IMT-2000 System (CDMA 방식의 IMT-2000 시스템에서 음성 및 데이터 트래픽에 대한 역방향링크의 성능 평가)

  • Lee, Hyun;Kang, Bob-Joo;You, Young-Gap;Cho, Kyoung-Rok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.657-665
    • /
    • 2000
  • In this study, the bit error rate(BER) performance for the speech and data traffic is evaluated by results of the reverse link simulation of CDMA-based IMT-2000. Simulations in the reverse link are achieved for indoor, pedestrian, and vehicular environments, which are provided by ITU-R . Also, in the these simulations, the fast power control of 1.6kHz rate is applied. The amplitude and phase of the fading signal are estimated by using the 5-tap FIR filter, and the soft-decision Viterbi and Reed-Solomon (RS) decoding are applied. Simulation results provide the optimum ratio of pilot power to traffic power, the BER performance according to the number of fingers, and performance comparison between convolutional code and concatenated code at $10^-6$ BER in 5 MHz system.

  • PDF

A Design of RF Digital Remote Water Gauge with Counterflow Detection Capability (역류 흐름 검출기능을 갖는 무선 디지털 원격 수도검침기 설계)

  • Nam, Jong-Hyun;Lee, Jae-Min
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.97-104
    • /
    • 2015
  • The conventional 1 Hall sensor-type water gauge has some defects that it can not detect counterflow and low-speed flow of water, and it also generates power consumption during even sleep mode. In this paper, a low-power consumption wireless digital remote water gauge with a counterflow detection capability is proposed. The proposed water gauge detects the direction and amount of water flow by using the three Hall sensors placed at $120^{\circ}$ intervals with 8-year national standard life durability. The water gauge with three Hall sensors works without error regardless of water speed does not generate power dissipation during sleep mode by presented reading algorithm for bew water gauge. The proposed water gauge is designed to send its ID, current time and counting value to repeater or central control center with specified frequency by RF Module.

Service Class-Aided Scheduling for LTE (LTE를 위한 서비스 클래스를 고려한 스케줄링 기법)

  • Hung, Pham;Hwang, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.11
    • /
    • pp.60-66
    • /
    • 2011
  • LTE (Long Term Evolution) supports QoS (Quality of Service) with several service classes. For each class of traffic, a big difference exists on BER (Bit Error Rate) requirement. This leads to a considerable difference in transmission power for various classes of traffic. In this paper, a novel scheduler is designed and proposed for LTE which supports CoS (Class of Service) with the consideration of priority as well as target BER. By the CQI (Channel Quality Indicator) and QCI (QoS Class Identifier), a minimum transmission power is assigned from the target BER for each class of traffic per each user. Hence, with the other information such as user's used rate in the past and the priority of traffic, the probability of occupying channels is determined. The simulation results of Service Class scheduling are compared with that of Maximum Rate and Proportional Fair. The results show that the service class-aided scheduling can improve the throughput of whole system significantly.

Low Power MAC Protocol Design for Wireless Sensor Networks using Recursive Estimation Methods (회귀적 추정 방식을 이용한 무선 센서 네트워크용 저전력 MAC 프로토콜)

  • Pak, Wooguil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.239-246
    • /
    • 2014
  • In the context of wireless sensor networks, one of major issues is energy conservation. For low power communication, by utilizing our experimental results for the relation between clock drift and synchronization interval, we designed a new protocol which can support a wide range of duty cycles for applications with very low traffic rate and insensitive delay. The transmission (TX) node in the protocol synchronizes with the reception (RX) node very before transmitting a packet, and it can adaptively estimate the synchronization error size according to the synchronization interval from minutes to hours. We conducted simulations and a testbed implementation to show the efficacy of the proposed protocol. We found that our protocol substantially outperforms other state-of-the-art protocols, resulting in order-of-magnitude increase in network lifetime over a variety of duty cycles.

A Framework to Evaluate Communication Quality of Operators in Nuclear Power Plants Using Cosine Similarity (코사인 유사도를 이용한 원자력발전소 운전원 커뮤니케이션 품질 평가 프레임워크)

  • Kim, Seung-Hwan;Park, Jin-Kyun;Han, Sang-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.9
    • /
    • pp.165-172
    • /
    • 2010
  • Communication problems have been regarded as one of the biggest causes in trouble in many industries. This led to extensive research on communication as a part of human error analysis. The results of existing researches have revealed that maintaining a good quality of communication is essential to secure the safety of a large and complex process system. In this paper, we suggested a method to measure the quality of communication during off-normal situation in main control room of nuclear power plants. It evaluates the cosine similarity that is a measure of sentence similarity between two operators by finding the cosine of the angle between them. To check the applicability of the method to evaluate communication quality, we compared the result of communication quality analysis with the result of operation performance that was performed by operators under simulated environment.

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.

QoS-Aware Call Admission Control for Multimedia over CDMA Network (CDMA 무선망상의 멀티미디어 서비스를 위한 QoS 제공 호 제어 기법)

  • 정용찬;정세정;신지태
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.12
    • /
    • pp.106-115
    • /
    • 2003
  • Diverse multimedia services will be deployed at hand on 3G-and-beyond multi-service CDMA systems in order to satisfy different quality of service (QoS) according to traffic types. In order to use appropriate resources efficiently the call admission control (CAC) as a major resource control mechanism needs to be used to take care of efficient utilization of limited resources. In this paper, we propose a QoS-aware CAC (QCAC) that is enabled to provide service fairness and service differentiation in accordance with priority order and that applies the different thresholds in received power considering different QoS requirements such as different bit error rates (BER) when adopting total received power as the ceil load estimation. The proposed QCAC calculates the different thresholds of the different traffic types based on different required BER applies it for admission policy, and can get service fairness and differentiation in terms of call dropping probability as a main performance metric. The QCAC is aware of the QoS requirement per traffic type and allows admission discrimination according to traffic types in order to minimize the probability of QoS violation. Also the CAC needs to consider the resource allocation schemes such as complete sharing (CS), complete partitioning (CP), and priority sharing(PS) in order to provide fairness and service differentiation among traffic types. Among them, PS is closely related with the proposed QCAC having differently calculated threshold per each traffic type according to traffic priority orders.

Optimization of Wind Turbine Pitch Controller by Neural Network Model Based on Latin Hypercube (라틴 하이퍼큐브 기반 신경망모델을 적용한 풍력발전기 피치제어기 최적화)

  • Lee, Kwangk-Ki;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1065-1071
    • /
    • 2012
  • Wind energy is becoming one of the most preferable alternatives to conventional sources of electric power that rely on fossil fuels. For stable electric power generation, constant rotating speed control of a wind turbine is performed through pitch control and stall control of the turbine blades. Recently, variable pitch control has been implemented in modern wind turbines to harvest more energy at variable wind speeds that are even lower than the rated one. Although wind turbine pitch controllers are currently optimized using a step response via the Ziegler-Nichols auto-tuning process, this approach does not satisfy the requirements of variable pitch control. In this study, the variable pitch controller was optimized by a genetic algorithm using a neural network model that was constructed by the Latin Hypercube sampling method to improve the Ziegler-Nichols auto-tuning process. The optimized solution shows that the root mean square error, rise time, and settle time are respectively improved by more than 7.64%, 15.8%, and 15.3% compared with the corresponding initial solutions obtained by the Ziegler-Nichols auto-tuning process.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

A Method of Reproducing the CCT of Natural Light using the Minimum Spectral Power Distribution for each Light Source of LED Lighting (LED 조명의 광원별 최소 분광분포를 사용하여 자연광 색온도를 재현하는 방법)

  • Yang-Soo Kim;Seung-Taek Oh;Jae-Hyun Lim
    • Journal of Internet Computing and Services
    • /
    • v.24 no.2
    • /
    • pp.19-26
    • /
    • 2023
  • Humans have adapted and evolved to natural light. However, as humans stay in indoor longer in modern times, the problem of biorhythm disturbance has been induced. To solve this problem, research is being conducted on lighting that reproduces the correlated color temperature(CCT) of natural light that varies from sunrise to sunset. In order to reproduce the CCT of natural light, multiple LED light sources with different CCTs are used to produce lighting, and then a control index DB is constructed by measuring and collecting the light characteristics of the combination of input currents for each light source in hundreds to thousands of steps, and then using it to control the lighting through the light characteristic matching method. The problem with this control method is that the more detailed the steps of the combination of input currents, the more time and economic costs are incurred. In this paper, an LED lighting control method that applies interpolation and combination calculation based on the minimum spectral power distribution information for each light source is proposed to reproduce the CCT of natural light. First, five minimum SPD information for each channel was measured and collected for the LED lighting, which consisted of light source channels with different CCTs and implemented input current control function of a 256-steps for each channel. Interpolation calculation was performed to generate SPD of 256 steps for each channel for the minimum SPD information, and SPD for all control combinations of LED lighting was generated through combination calculation of SPD for each channel. Illuminance and CCT were calculated through the generated SPD, a control index DB was constructed, and the CCT of natural light was reproduced through a matching technique. In the performance evaluation, the CCT for natural light was provided within the range of an average error rate of 0.18% while meeting the recommended indoor illumination standard.