• Title/Summary/Keyword: Power Control Error

Search Result 1,081, Processing Time 0.033 seconds

통신위성 전력제어 및 분배장치 설계 및 해석

  • Choi, Jae-Dong
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.108-116
    • /
    • 2003
  • This research presents the design and analysis of PCDU(Power Control & Distribution Unit) of communication satellite. The PCDU of a spacecraft must provide adequate power to each subsystem and payload during mission life, and it also needs high reliability and performance in space environment. A control circuit of the PCDU include bus sensing and filter circuits, error signal amplification circuit, error compensation circuit of SAS(Shunt Assembly Switch) and BPC(Battery Power Converter). The phase margin and DC gain for the designed circuits are analyzed through the frequency response characteristics of the compensated control circuit. And also the transfer function of the battery power converter circuit are discussed at the battery CCCM(Charge Continuous Conduction Mode) and battery C/DCCM(Continuous/Discontinuous Conduction Mode).

  • PDF

A Stability Analysis of Bus Controller of Power Control Unit for GEO Satellite (정지궤도위성 전력조절장치 버스제어기 안정도해석)

  • Choi Jaedong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.874-877
    • /
    • 2004
  • This paper presents the bus controller analysis of a power control unit of GEO satellite with 3kW power output. The sensing error of bus voltage produce control signal of the shunt switch assembly and the battery power converter, and the tolerance of error signal generated decide the stability of proposed system. The worst case analysis considered for the initial tolerance, temperature effect, tolerance of end of life is peformed to verify a designed bus controller. And also, the stability of system proposed according to moving of zero and pole values by some component failures is analyzed.

  • PDF

A New Control Method for an Adaptive Noise Canceller Using Stochastic difference between Voice and Noise Signals Power Change

  • Nishi, H.;Kakinoki, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2362-2367
    • /
    • 2005
  • This paper reports a technique for discriminating double talk and echo path change using the stochastic characteristics of power change for an adaptive noise canceller. The causes of rapid error increasing are double talk and echo path change. When the echo path is changed, the system corrects the impulse response in order to reduce the error. However, in the case of double talk, the system has to suspend the updating impulse response in order to maintain the quality of the voice signal. In the conventional system, it was difficult to discriminate between the two situations. In this research, the stochastic characteristics of the voice power change in the double talk period were experimentally verified to be different from the power change during echo path changing. Based on the results, a new double talk detection method is proposed.

  • PDF

Design of Fault Tolerant Control System for Steam Generator Using Fuzzy Logic

  • Kim, Myung-Ki;Seo, Mi-Ro
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.321-328
    • /
    • 1998
  • A controller and sensor fault tolerant system jot a steam generator is designed with fuzzy logic. A structure of the : proposed fault tolerant redundant system is composed of a supervisor and two fuzzy weighting modulators. A supervisor alternatively checks a controlled and a sensor induced performances to identify Which Part, a controller or a sensor, is faulty. In order to analyze controller induced performance both an error and a charge in error of the system output an chosen as fuzzy variables. The fuzzy logic jot a sensor induced performance uses two variables : a deviation between two sensor outputs and its frequency, Fuzzy weighting modulator generates an output signal compensated for faulty input signal. Simulations show that the : proposed fault tolerant control scheme jot a steam generator regulates welt water level by suppressing fault effect of either controllers or sensors. Therefore through duplicating sensors and controllers with the proposed fault tolerant scheme, both a reliability of a steam generator control and sensor system and that of a power plant increase even mote.

  • PDF

Analysis of Heliostat Sun Tracking Error due to the Mirror Installation and Drive Mechanism Induced Errors (Heliostat 반사거울 설치 및 구동기구 유발 오차에 의한 태양추적오차의 해석)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.1-11
    • /
    • 2009
  • Heliostat sun tracking accuracy could be the most important requirement in solar thermal power plant, since it determines the overall efficiency of power plant. This study presents the effect of geometrical errors on the heliostat sun tracking performance. The geometrical errors considered here are the mirror canting error, encoder reference error, heliostat position error. pivot offset and tilt error, gear backlash and mass unbalanced effect error. We first investigate the effect of each individual geometrical error on the sun tracking accuracy. Then, the sun tracking error caused by the combination of individual geometrical error is computed and analyzed. The results obtained using the solar ray tracing technique shows that the sun tracking error due to the geometrical error is varying almost randomly. It also shows that the mirror canting error is the most significant error source, while the encoder reference error and gear backlash are second and the third dominant source of errors.

Application of Fuzzy Integral Control for Output Regulation of Asymmetric Half-Bridge DC/DC Converter with Current Doubler Rectifier

  • Chung, Gyo-Bum;Kwack, Sun-Geun
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.238-245
    • /
    • 2007
  • This paper considers the problem of regulating the output voltage of a current doubler rectified asymmetric half-bridge (CDRAHB) DC/DC converter via fuzzy integral control. First, we model the dynamic characteristics of the CDRAHB converter with the state-space averaging method, and after introducing an additional integral state of the output regulation error, we obtain the Takagi-Sugeno (TS) fuzzy model for the augmented system. Second, the concept of parallel distributed compensation is applied to the design of the TS fuzzy integral controller, in which the state feedback gains are obtained by solving the linear matrix inequalities (LMIs). Finally, numerical simulations of the considered design method are compared to those of the conventional method, in which a compensated error amplifier is designed for the stability of the feedback control loop.

Control Transfer Optimization using Control Performance Assessment Methodology (Control Performance Assessment 기법을 적용한 제어 전환 최적화)

  • Lee, Kwang-Dae;Oh, Eung-Se;Yang, Seung-Ok;Kim, Jong-Won;Jeon, Dang-Hee;Hur, Jung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.425-426
    • /
    • 2008
  • 발전소의 제어 시스템은 제어 기간이 길어짐에 따라 제어 기기의 운전 특성이 변화하므로 최초 설계 및 운전때의 성능과는 다른 제어 특성을 나타낸다. 따라서 주기적으로 제어 성능을 평가하고 평가 결과에 따라서 제어 기기의 성능 개선 작업과 제어 시스템의 제어기 상수 최적화 등의 작업을 통하여 제어 성능을 최적으로 유지하여 제어 목적을 달성하도록 하여야한다. 제어성능 평가기법은 제어 목표 값에 대한 추종성을 평가하는 Set Print Analysis 방법을 주로 사용한다. 평가 지표는 Integral Absolute Error(IAE)와 같은 Error Integral 값과 Minimum Variance방법이 실용적으로 사용된다. 본 논문에서는 Non-Minimum Phase 특성으로 인하여 초기 운전 모드에서 정상 운전 모듈로의 원활한 전환이 어려운 수위 제어 시스템에서 제어 전환을 위한 최적 제어기 상수를 구하기 위하여 CPA 방법을 적용하였다. 일반적으로 제어성 평가는 설정치 변화에 대한 추종성을 평가하지만 본 논문에서는 제어 전환 시의 제어성 평가를 통하여 최적의 제어 전환 상수를 구하고자 하였다. 적용 결과, CPA기법은 설정시 추종성뿐만 아니라 제어 과도에서의 제어 전환 변수의 주종성에 적용하여 제어 전환을 최적화하는데도 유용함을 확인하였다.

  • PDF

Capacity of synchronous DS-CDMA system on frequency selective multipath fading channels with imperfect power control (주파수 선택적 다중 경로 페이딩 채널에서 불완전 전력 제어를 고려한 동기식 DS-CDMA 시스템의 수용 용량)

  • 황승훈;김용석;김동희;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.342-350
    • /
    • 2000
  • In this paper, the bit error performance for the reverse link of a synchronous direct sequence code division multiple access (DS-CDMA) system employing an imperfect power control scheme over a frequency selective Rayleigh fading channel is analyzed. The system capacity degradation due to power control error (PCE), which is approximated by a log-normally distributed random variable, is estimate as a function of a standard deviation of the PCE. In addition, the impact of the multipath intensity profile (MIP) shape and the number of resolvable paths on the performance of the synchronous transmission is investigated. To estimate the system capacity, the coded bit error performance is evaluated and compared with the conventional CDMA. It is found tat synchronous transmission has less sensitivity to imperfect power control and eases the power control requirements. In particular, as the decay constant $\delta$ of MIP increases, the synchronous transmission in the DS-CDMA reverse link results in a significant BER improvement over the asynchronous transmission even in the presence of imperfect power control. We further conclude that the capacity can be improved by employing the synchronous transmission.

  • PDF

Load Frequency Control of Multi-area Power System using Auto-tuning Neuro-Fuzzy Controller (자기조정 뉴로-퍼지제어기를 이용한 다지역 전력시스템의 부하주파수 제어)

  • Jeong, Hyeong-Hwan;Kim, Sang-Hyo;Ju, Seok-Min;Heo, Dong-Ryeol;Lee, Gwon-Sun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.3
    • /
    • pp.95-106
    • /
    • 2000
  • The load frequency control of power system is one of important subjects in view of system operation and control. That is even though the rapid load disturbances were applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow one on each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation were given, the unstable phenomenal of power system can be often brought out because of the large frequency deviation and the unsuppressible power line one. Therefore, it is desirable to design the robust neuro-fuzzy controller which can stabilize effectively the given power system as soon as possible. In this paper the robust neuro-fuzzy controller was proposed and applied to control of load frequency over multi-area power system. The architecture and algorithm of a designed NFC(Neuro-Fuzzy Controller) were consist of fuzzy controller and neural network for auto tuning of fuzzy controller. The adaptively learned antecedent and consequent parameters of membership functions in fuzzy controller were acquired from the steepest gradient method for error-back propagation algorithm. The performances of the resultant NFC, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the load frequency control of multi-area power system, when the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbances of internal parameters and external stepwise load stepwise load changes, the superiorities of the proposed NFC in robustness and adaptive rapidity to the conventional controllers were proved.

  • PDF

The Buck DC-DC Converter with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • Kim Sang-Don;Ra Byung-Hun;Lee Hyun-Woo;Kim Kwang-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.470-475
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of do-dc converter. In this control method, the duty ratio of a switch is exactly equal In or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM

  • PDF