• Title/Summary/Keyword: Power Control Error

Search Result 1,081, Processing Time 0.028 seconds

Performance Improvement of Distributed FLC by Nonuniform Membership Functions (비균일 멤버쉽 함수를 이용한 분산 퍼지제어 성능 향상)

  • 박희경;공성곤
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.37-40
    • /
    • 1997
  • This paper presents a performance improvement of distributed fuzzy control system by changing the triangular membership function widths according to the input variables. The control region consists of 4 parts according to the sign of error and change of error terms. Each control part is operated by the suitable nonuniform triangular membership function. Through the simulation for the boiler-turbin model of a fossil power plant using decentralized contol, it is verified this proposal

  • PDF

Synchronous PI Decoupling Control Scheme for DVR against a Voltage Sag in the Power System

  • Kim, Myung-Bok;Lee, Seung-Hoon;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.180-187
    • /
    • 2004
  • This paper proposes a new control strategy for the dynamic voltage restorer (DVR). It is based on a synchronous PI decoupling control strategy which features fast response time and low steady state error. Therefore, the proposed control strategy produces faster action time against voltage sag and guarantees more than enough compensation for reduced supply voltage. Experimental results, implemented with the TMS320C3${\times}$DSP control unit, are shown to validate the effectiveness of the proposed control strategy.

Optimum Control Period and Perturbation Voltage for PV-MPPT Controller Considering Real Wether Condition (실제 날씨를 고려한 PV-MPPT 제어기의 최적 주기와 변량전압)

  • Ryu, Danbi;Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.1-5
    • /
    • 2020
  • Solar power generation systems require maximum power point tracking (MPPT) control to operate PV panels at their maximum power point (MPP). Most conventional MPPT algorithms are based on the slope-tracking concept. A typical slope-tracking method is the perturb and observe (P&O) algorithm. The P&O algorithm measures the current and voltage of a PV panel to find the operating point of the voltage at which the calculated power is maximized. However, the measurement error of the sensor causes irregularity in the calculation of the generated power and voltage control. This irregularity leads to the problem of not finding the correct MPP operating point. In this work, the power output of a PV panel based on the P&O algorithm is simulated by considering the insolation profiles from typical clear and cloudy weather conditions and the errors of current and voltage sensors. Simulation analysis suggests the optimal control period and perturbation voltage of MPPT to maximize its target efficiency under real weather conditions with sensor tolerance.

Design and Stability Analysis of a Fuzzy Adaptive SMC System for Three-Phase UPS Inverter

  • Naheem, Khawar;Choi, Young-Sik;Mwasilu, Francis;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.704-711
    • /
    • 2014
  • This paper proposes a combined fuzzy adaptive sliding-mode voltage controller (FASVC) for a three-phase UPS inverter. The proposed FASVC encapsulates two control terms: a fuzzy adaptive compensation control term, which solves the problem of parameter uncertainties, and a sliding-mode feedback control term, which stabilizes the error dynamics of the system. To extract precise load current information, the proposed method uses a conventional load current observer instead of current sensors. In addition, the stability of the proposed control scheme is fully guaranteed by using the Lyapunov stability theory. It is shown that the proposed FASVC can attain excellent voltage regulation features such as a fast dynamic response, low total harmonic distortion (THD), and a small steady-state error under sudden load disturbances, nonlinear loads, and unbalanced loads in the existence of the parameter uncertainties. Finally, experimental results are obtained from a prototype 1 kVA three-phase UPS inverter system via a TMS320F28335 DSP. A comparison of these results with those obtained from a conventional sliding-mode controller (SMC) confirms the superior transient and steady-state performances of the proposed control technique.

Power Transmission from a Vibrating Mass to a Supporting Elate through Isolators (능동 및 수동격리기를 적용한 진동계에 있어서 힘의 전달에 관한 연구)

  • Jin-Woo Lee;Colin H. Hansen
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.200-207
    • /
    • 2001
  • The transmission of harmonic vibratory power form a vibrating rigid body into a supporting plate through passive and active isolators is investigated theoretically and experimentally. The theoretical model allows for the transmission of vertical and horizontal harmonic forces and moments about all three coordinate sun. The experiment is to use vibration actuators attached to the intermediate mass of the two-stage mount to minimize the rotational and translational vibration of the intermediate mass. The performance is done by measuring the vibration at the error sensors due to the primary vibration source and measuring the transfer functions from the control sources to the error sensors. Results show that over a frequence range from 1 to 100Hz, transmission into the supporting plate can be reduced substantially by employing in parallel with existing passive isolators, active isolators adjusted to provide appropriate control force amplitudes.

  • PDF

Influence of Resistance Error to the Bandwidth of Back-EMF Estimation based SMPMSM Sensorless Drives (역기전력 추정 기반 SMPMSM 센서리스 드라이브에서 저항 오차가 대역폭에 미치는 영향)

  • Kim, Jae-Suk;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.418-426
    • /
    • 2016
  • This paper analyzes the effect of resistance error to the performance of sensorless drive system of surface-mounted permanent magnet synchronous machine (SMPMSM) based on the back-EMF observer. The analysis shows that the bandwidth of the entire sensorless drive system decreased in the low-speed region when using smaller resistance value than the actual one in the back-EMF observer. Even if the back-EMF observer invokes estimation error, the entire sensorless drive system does not make any steady-state position error. These characteristics may have positive effects such as extension of the low speed limit that goes further down in the sensorless drive. The validity of the analysis is verified by the experimental setup comprising the MG set.

Position Control of Stepping Motor using Torque Angle Control Scheme (토크 각도제어기법을 적용한 스테핑 전동기의 위치제어)

  • Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • This paper presents high speed position controller using stepping motor. The proposed position controller has close loop and open loop mode. In the high speed region, torque angle which is controlled by PI controller and memory based look-up table, is used to keep the reference position. The memory based look-up table produces a torque angle according to motor speed, and the PI controller can compensate the torque angle error. So, the fast dynamic response can be expected in the same position error. The open loop control mode which is divided by 3-modes control the actual position in the low speed and small position error. Each open loop modes are designed to reduce position error and dynamic brake in the stop command. The proposed position control scheme is verified by the practical stepping motor.

Design of BLDC Motor Controller for Electric Power Wheelchair

  • Chu, Jun-Uk;Moon, In-Hyuk;Choi, Gi-Won;Ryu, Jei-Cheong;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1509-1512
    • /
    • 2003
  • The electric power wheelchair needs to control motor torque and speed for responding to variable actions given by handling a joystick. In this paper a DSP-based BLDC motor controller using a single dc-link current sensor is presented for electric power wheelchair. It is composed by a DSP processor and three-phase inverter module. To control torque, high speed current control is achieved by the PI controller and pulse width modulation (PWM) signals with 25 kHz carrier frequency, which is performed by 200 ${\mu}sec$ cycle. The speed controller computes the new direct current reference from the speed error and the PI control equation. The displacement value by handling the joystick is converted to reference speeds of right and left wheel motors using nonholonomic wheelchair kinematics. Experimental results show that the presented control system is enough to implement a speed servo in wheelchair driving.

  • PDF

Motor Protection and Control with Digital Protective Relays (디지털 보호 계전기를 이용한 모터 보호 및 제어)

  • 이성환;안인석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.178-178
    • /
    • 2000
  • In this paper, intelligent methods using digital protection relay in power management and control system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to Protect and measure more quickly and precisely. The test result on the basis of KEMCl120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within $\pm$5%. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Power Monitoring and Distributed Control by Digital Relay (디지털 계전기를 이용한 전력감시 및 분산제어)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.263-266
    • /
    • 2001
  • In this paper, intelligent methods using digital protection relay in power SCADA system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. The test result on the basis of KEMC 1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF