• 제목/요약/키워드: Power Consumption Capacity

검색결과 365건 처리시간 0.031초

대전지역 공동주택의 전력소비 실태 및 패턴 분석 연구 (An Analysis of Electricity Consumption Profile based on Measurement Data in Apartment Complex in Daejeon)

  • 김강식;임경업;윤종호;신우철
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.91-96
    • /
    • 2011
  • This study is to analysis the characteristics of electric power consumption of apartments complex in Korea. This study shows the pattern of electric power consumption and correlation of each apartment complex's completion year monthly and timely. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. It is expected this data is used as reference of electric consumption of Daejeon area to operate the simulation tools to predict the building energy. The yearly data of 10 apartment complexes of 2010 are analyzed. The results of this study are followed. The averaged amount of electricity consumption in winter is higher as summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 310.2kWh. A week is seperated, as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.426kWh. The Saturday consumption is 0.437kWh. The Sunday is 0.445kWh. The peak electricity consumption in summer and winter is measured. The peak consumption on summer season is 1.389kW on 22th August 64% higher than winter season 0.887kW on 3rd January.

지하철 역사의 구조 및 특성을 고려한 동력부하밀도 분석 (Power Load Density Analysis considering Structure and Characteristics of Subway Stations)

  • 정현기;차광석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.912-920
    • /
    • 2006
  • The purpose of this study is to present the design standard for load density in subway station. From the data of electric equipment capacity and electric power consumption for 43 subway stations, current levels of the load density and excess capacity factor were surveyed and analyzed, In addition mean value, standard deviation, maximum value, median value and correlation coefficient were evaluated through excel program. Also it was carried out the regression analysis. The estimation method of load density and design criterion were studied. As a result, load density in this thesis have been proposed : 51.3 $[VA/m^2]$ on the general power load can be a standard value for subway station.

  • PDF

Slider-Bearing Design with Micro-Machined Wavy-Cavity: Parametric Characterization of Thermohydrodynamic-Operation-Scheme

  • Ozalp B. Turker;Ozalp A. Alper
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1590-1606
    • /
    • 2006
  • Slider bearings are widely applied in mechanical systems, where the design needs cover increased load capacity, lowered friction and power consumption and creative designs. This work is governed to perform a parametric characterization, by generating a novel structure on the upper slider surface, which can formally be expressed in micro-machined wavy-form, where the individual and combined influences of various structural design parameters and boundary conditions, on the performance records, are also evaluated. Computations put forward that the contribution of the wave amplitude on power loss values is highly dependent on the level of inlet pressure; higher amplitudes are determined to increase power loss in the lowest inlet pressure case of 1.01, whereas the contrary outcome is determined in the higher inlet pressure cases of 3.01 & 5.01. Designing the slider bearing system, based on optimal load capacity, produced the optimum wave number ranges as 10-45, 7-11 and 5-8 for the pad inclinations of $5^{\circ},\;4^{\circ}$ and $3^{\circ}$ respectively.

AMR 데이터에서의 전력 부하 패턴 분류 (Power Load Pattern Classification from AMR Data)

  • ;박진형;이헌규;신진호;류근호
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 춘계학술발표대회
    • /
    • pp.231-234
    • /
    • 2008
  • Currently an automated methodology based on data mining techniques is presented for the prediction of customer load patterns in load demand data. The main aim of our work is to forecast customers' contract information from capacity of daily power consumption patterns. According to the result, we try to evaluate the contract information's suitability. The proposed our approach consists of three stages: (i) data preprocessing: noise or outlier is detected and removed (ii) cluster analysis: SOMs clustering is used to create load patterns and the representative load profiles and (iii) classification: we applied the K-NNs classifier in order to predict the customers' contract information base on power consumption patterns. According to the our proposed methodology, power load measured from AMR(automatic meter reading) system, as well as customer indexes, were used as inputs. The output was the classification of representative load profiles (or classes). Lastly, in order to evaluate KNN classification technique, the proposed methodology was applied on a set of high voltage customers of the Korea power system and the results of our experiments was presented.

관순법을 이용한 공조기 사이클 시뮬레이션 (Air-conditioner cycle simulation using tube-by-tube method)

  • 윤백;박현연;유국철;김용찬
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.499-510
    • /
    • 1999
  • A computer program was developed for simulating performance(capacity, power consumption and etc.) of air-conditioners using compressor, fin-tube heat exchanger and capillary tube. The program consists of five modules, condenser, evaporator, compressor, capillary tube simulation modules and properties modules of refrigerant and moist air, The present program is focused on R22 only, however can be easily extended for other refrigerants such as R407C and R410A just by adding property modules. The compressor simulation module utilizes performance maps supplied by manufacturers-map-based model. The condenser and evaporator simulation modules are modeled using tube-by-tube method. Simulation results(capacity and power consumption) were compared with calorimeter test results of actual air-conditioners of window and split types, where more than 82% of the data lied within ${\pm}5$% of the predicted results.

  • PDF

Performance Analysis Based on RAU Selection and Cooperation in Distributed Antenna Systems

  • Wang, Gang;Meng, Chao;Heng, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권12호
    • /
    • pp.5898-5916
    • /
    • 2018
  • In this paper, the downlink performance of multi-cell distributed antenna systems (DAS) with a single user in each cell is investigated. Assuming the channel state information is available at the transmitter, four transmission modes are formulated as combinations of remote antenna units (RAUs) selection and cooperative transmission, namely, non-cooperative transmission without RAU selection (NCT), cooperative transmission without RAU selection (CT), non-cooperative transmission with RAU selection (NCT_RAUS), and cooperative transmission with RAU selection (CT_RAUS). By using probability theory, the cumulative distribution function (CDF) of a user's signal to interference plus noise ratio (SINR) and the system ergodic capacity under the above four modes are determined, and their closed-form expressions are obtained. Furthermore, the system energy efficiency (EE) is studied by introducing a realistic power consumption model of DAS. An expression for determining EE is formulated, and the closed-form tradeoff relationship between spectral efficiency (SE) and EE is derived as well. Simulation results demonstrate their consistency with the theoretical analysis and reveal the factors constraining system EE, which provide a scientific basis for future design and optimization of DAS.

육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석 (Thermal load analysis of tank culture system for applying seawater source heat pump)

  • 윤민기;김태훈;정석권
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

연료전지 하이브리드 차량의 연비향상을 위한 배터리 동력분배 최적화 (Optimization of Battery Power Distribution to Improve Fuel Consumption of Fuel Cell Hybrid Vehicle)

  • 이동섭
    • 대한기계학회논문집A
    • /
    • 제37권3호
    • /
    • pp.397-403
    • /
    • 2013
  • 친환경 및 연비에 대한 요구와 제한은 하이브리드 차량과 같은 친환경 고연비 차량기술을 발전시켜왔다. 하이브리드 차량의 연비는 시스템의 특성으로 인해 주행 후 배터리 충전량의 변화를 연비에 반영시키는 등가연료사용량이 연료소비량에 추가되므로 제어전략에서 배터리 사용영역 증가만으로 연비를 향상시킬 수 없었다. 본 논문은 연료전지 하이브리드 차량을 matlab simulink상에서 모델링하고 기존제어전략에서 연료전지의 사용구간을 분석하여 연료전지 주 사용영역에서의 배터리와 연료전지 간 동력분배를 연비향상을 목표로 최적화하여 등가연료사용량을 포함한 총연비의 향상을 시도하였다.

듀얼채널을 적용한 반도체공정용 칠러의 실험적 연구 (An Experimental Study on Semiconductor Process Chiller for Dual Channel)

  • 차동안;권오경
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.760-766
    • /
    • 2010
  • Excessive heat occurs during semiconductor manufacturing process. Thus, precise control of temperature is required to maintain constant chamber-temperature and also wafer-temperature in the chamber. Compared to an industrial chiller, semiconductor chiller's power consumption is very high due to its continuous operation for a year. Considering the high power consumption, it is necessary to develop an energy efficient chiller by optimizing operation control. Therefore, in this study, a semiconductor chiller is experimentally investigated to suggest energy-saving direction by conducting load change, temperature rise and fall and control precision experiments. The experimental study shows the cooling capacity of dual-channel chiller rises over 30% comparing to the conventional chiller. The time and power consumption in the temperature rising experiment are 43 minutes and 8.4 kWh, respectively. The control precision is the same as ${\pm}1^{\circ}C$ at $0^{\circ}C$ in any cases. However, it appears that the dual channel's control precision improves to ${\pm}0.5^{\circ}C$ when the setting temperature is over $30^{\circ}C$.

다중홉 Ad-hoc 환경에서 에너지 효율적인 릴레이 선택 방안 (Energy Efficient Relay Selection in a Multi-hop Ad-hoc Environment)

  • 정해범;김송희;김덕경
    • 한국통신학회논문지
    • /
    • 제37권5B호
    • /
    • pp.327-337
    • /
    • 2012
  • 릴레이를 사용한 시스템에서 최적의 릴레이 위치에 대한 연구가 많이 진행되어 왔지만, 지금까지는 송신단과 릴레이의 전송 전력의 합이 제한된 경우에 전송 용량을 최대화하는 연구가 대부분이었다. 그러나 Ad-hoc 네트워크와 같이 릴레이가 제한된 용량의 배터리를 에너지원으로 사용하는 경우, 에너지 소모를 효율적으로 절약하는 것이 필요하다. 본 논문은 AF(Amplify-and-Forward) 릴레이를 사용한 두 홉 시스템에서 수신단의 신호 대 잡음비가 고정된 경우, 특정 전송 품질을 만족시키기 위해 릴레이에서 사용하는 전력을 최소화하는 최적 릴레이 위치 선정 방안을 제안한다. 모의실험을 통해 Ad-hoc 환경에서의 제안된 기법이 에너지 소모 측면에서 더 효율적임을 보이고, 다중 홉으로 확장된 시스템에서 제안된 기법의 경우 더 낮은 전송실패확률을 갖는 것을 확인한다.