• 제목/요약/키워드: Potentiometric Titration

검색결과 92건 처리시간 0.022초

DEVELOPMENT OF ADSORBENT USING BYPRODUCTS FROM KOREAN MEDICINE FOR REMOVING HEAVY METALS

  • Kim, S.W.;Lim, J.L.
    • Environmental Engineering Research
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2007
  • Most of the herb residue producing from oriental medical clinics(OMC) and hospitals(OMH) is wasted in Korea. To develop of adsorbent for removing heavy metal from wastewater, the various pre-treatment methods of the herb residue were evaluated by potentiometric titration, Freundlich isotherm adsorption test and the kinetic adsorption test. The herb residue was pre-treated for increasing the adsorption capacity by cleaning with distilled water, 0.1 N HCl and 0.1 N NaOH and by heating at $370^{\circ}C$ for 30 min. It showed a typical weak acid-weak base titration curve and a short pH break like commercial activated carbon during photentiometric titration of pre-treated herb residue. The log-log plots in the Freundlich isotherm test were linear on the herb residue pre-treated with NaOH or HCl like commercial activated carbon. The adsorption capacity(qe) in the Freundlich isotherm test for $Cr^{6+}$ was 1.5 times higher in the pre-treated herb residue with HCl than in activated carbon. On the other hand the herb residue pre-treated with NaOH showed the good adsorption capacities for $Pb^{2+}$, $Cu^{2+}$ and $Cd^{2+}$ even though those adsorption capacities were lower than that of activated carbon. In kinetic test, most of heavy metals removed within the first 10 min of contact and then approached to equilibrium with increasing contact time. The removal rate of heavy metals increased with an increase of the amount of adsorbent. Likewise, the removal rates of heavy metals were higher in the herb residue pre-treated with NaOH than in that pre-treated with HCl. The adsorption preference of herb residues pre-treated with NaOH or HCl was $Pb^{2+}>Cu^{2+}$ or $Cd^{2+}>Cr^{6+}$ in the order. Conclusively, the herb residue can be used as an alternative adsorbent for the removal of heavy metals depending on pr-treatment methods.

Chloride Meter(CL-2Z형)를 이용한 담배잎 중 chloride의 신속한 검정방법 (Rapid Quantification of Chloride in Tobacco Leaves by a Chloride Meter (Model: CL-2Z))

  • 이미경;정훈채;김용연;윤연현
    • 한국연초학회지
    • /
    • 제28권2호
    • /
    • pp.83-93
    • /
    • 2006
  • The aim of this study is to develop a simple and rapid field method for the determination of chloride content in tobacco green or cured leaves. To set up a practical process, several factors such as the proper sampling position of each leaf, the size of leaf lamina pieces for blending, the substitution of deionized water fur the extracting solution, 0.1N $HNO_3$, the submerging durations before blending, and the standing times before measuring were studied using flue-cured and burley tobacco with a stable and reproducible Chloride Meter, KRK CL-2Z. From the results, chloride contents of tobacco leaves could be analyzed with the Chloride Meter(CL-2Z) using the suspension of 14 mm diameter leaf disks after soaking in distilled water for 30 min., blending with a mini-blender for 30 seconds. The chloride contents measured in this way showed highly significant correlations with ones by the conventional potentiometric method using an ion meter-chloride electrode and $AgNO_3$ titration. In our method, the procedures such as drying, powdering and weighing samples, and using chemical reagents for extraction (0.1N $HNO_3$) and titration(0.028N $AgNO_3$) could be eliminated. These results suggest that the newly constructed method using the Chloride Meter is more efficient to determine the chloride content of tobacco leave in comparison with the one by the Ion $Meter:AgNO_3$ titration.

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권1호
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

중금속이몬(Cd2+,Pb2+,Zn2+,Cu2+)제거를 위한 질소를 주개원자로 하는 리간드들의 착화합물 형성에 관한 연구 (The Study of Nitrogen Doner Atoms Chelating Compounds for Removing Heavy Metals (Cd2+,Pb2+,Zn2+,Cu2+))

  • 김선덕;김준광;김정성
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.497-501
    • /
    • 2003
  • The new tridentate ligands of nitrogen donor atoms N,N-Bis(2-amino-ethyI)-benzyl-amine 2HCI(BABEA. 2HCI) and 2,6-Bis(amino-methyl)-pyridien. 2HCI(BAMP. 2HCI) were synthesized as their dihydrochloride salts and characterized by TA, IR. Mass and NMR spectroscopy. The protonation constants of the ligands and stability constants for Cd$^{2+}$, Pb$^{2+}$, Zn$^{2+}$and Cu$^{2+}$ ions were determined by potentiometric titration in aqueous solutions and compared with those of analogous ligands. The effect stability constants of ligands and metal ions for removal of heavy metals in aqueous solution were described.

Highly Selective Triiodide Polymeric Membrane Electrode Based on Tetra(p-chlorophenyl)porphyrinato Manganese (Ⅲ) Acetate

  • Farhadi, Khalil;Shaikhlouei, Hossain;Maleki, Ramin;Sharghi, Hashem;Shamsipur, Mojtaba
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1635-1639
    • /
    • 2002
  • A new solvent polymeric membrane sensor based on tetra(p-chlorophenyl)porphyrinato manganese (III) acetate is described which demonstrates excellent selectivity toward the triiodide ion. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ M and 7.0 ${\times}$$10^{-6}$M with a Nernstian slope of $-59.6{\pm}1$ mV per decade and a detection limit of 5.0 ${\times}$$10^{-6}$M. The proposed sensor revealed good selectivities for triiodide over a wide variety of other anions and could be used in a pH range 2-9. The electrode can be used for at least two months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of the triiodide and As(III) ions.

Maltitol의 제제학적(製劑學的) 성질(性質)에 관(關)한 연구(硏究) (Pharmaceutical Properties of Maltitol)

  • 박주석;김재백
    • Journal of Pharmaceutical Investigation
    • /
    • 제9권4호
    • /
    • pp.23-28
    • /
    • 1979
  • The effect of maltitol admininstration to rat was studied on breakdown of ${\alpha}-glycoside$ linkage with intestinal mucosa or pancreatic enzymes and induction of hepatic polyol dehydrogenase activities. Maltitol was contained as 13% or 26% in diet, and was administrated to rat for 9 weeks. This report carried out that ${\alpha}-glycoside$ linkage of maltitol was not hydrolyzed with pancreatic enzymes and intestinal mucosa. Maltitol dehydrogenase was not obeserved in liver cytoplasm, and hepbtic sorbitol dehydrogenase was not induced by maltitol administsation. Also, the effect of maltitol on aging of aluminum hydroxide gel, prepared by the reaction of aluminum chloride solution with strong ammonia solution to final pH 7.0, was studied by potentiometric titration, pH and acid-consuming capacity. Gel containing 1% or 2% maltitol was lost less than 2% of their acid-consuming capacity during a 120 days aging period compared with a loss of more than for an identical gel without maltitol and gel containing 0.5% maltitol.

  • PDF

고 탈아세틸화도를 갖는 카이토산의 제조와 그의 특성에 관한 연구 (A Study on the Preparation and Characterization of Highly Deacetylated Chitosan)

  • 배현숙
    • 한국의류학회지
    • /
    • 제20권4호
    • /
    • pp.682-689
    • /
    • 1996
  • A preparative method has been proposed for obtaining chitosan products which have a desired degree of deacetylation (DD, %) without much decrease in molecular weight. Deacetylation was prepared by two methods. The method I which was proposed by Domard etc. was that DMSO/thiophenol was used repeatedly only during the deacetylation, the method II was that DMSO/thiophenol was used after the alkali treatment. Then, effective deacetylation was performed by the method ll. To determine the degree of deacetylation, potentiometric titration method was adopted. According to the increase of DD, the viscosity average moleclar weght $(\overline{M\upsilon}$) and the DP of the chitosan products were decreased. The intensity of FT-lR peak appeared at $1655cm^{-1}, which was characteristic peak of amide I (Nacetyl secondary amide group), was gradually decreased with deacetylation. X-ray analysis showed that the lattice-spacing in the chitosan film increased with the degree of deacetylation, but the difference of the transparency of the chitosan products was not diverged significantly.

  • PDF

수용액상에서 Infrared Spectra를 이용한 Butyldithiodiacetic Acid, Benzmethyldithiodiacetic Acid, Cyclohexyldithiodiacetic Acid의 특성에 관한 연구 (Characterazation of Butyldithiodiacetic Acid, Benzmethyldithiodiacetic Acid and Cyclohexyldithiodiacetic Acid used Infrared Spectra in Aqueous Solution)

  • 도길명;김일출;최보용
    • 대한화학회지
    • /
    • 제39권3호
    • /
    • pp.213-217
    • /
    • 1995
  • 수용액상에서 BUDDA(Butyldithiodiacetic acid), BMDDA(Benzmethyldithiodiac-etic acid), CHDDA(Cyclohexyldithiodiacetic acid)의 IR 스펙트라는 다양한 pH값에서 보고되어진다. 이온화된 carboxyl group과 비이온화된 carboxyl group의 비대칭 신축진동 흡수띠 차이를 이용하여 free-ligand의 구조를 추정한다. 또한 이들 연구의 접근은 리간드의 IR 스펙트라와 전위차 적정법을 이용하여 얻어진 $pk_a$값을 비교함으로서 설명된다.

  • PDF

고분자 물질을 사용한 토양 중 방사성 핵종의 고정화

  • 원휘준;김계남;김민길;오원진
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.293-297
    • /
    • 2003
  • A series of laboratory experiments was conducted to investigate the fixation characteristics of poly(vinylalcohol)-poly(methacrylic acid)(PVA-PMAA) mixed solution on the soluble (equation omitted)-radionuclides. Using the potentiometric titration technique, it was found out that the PVA and PMAA in a solution form intermacromolecular complex. The mobilized portion of each radionuclide by water from sand surface treated with a fixative was measured by ${\gamma}$-ray spectroscopy, The mobilized portion of minor radionuclides such as $^{241}$ Am, $^{154}$ Eu, $^{155}$ Eu and $^{144}$ Ce were higher than those of $^{134}$ Cs and $^{137}$ Cs. The capability of PVA-PMAA system was better among the candidate solutions for the fixation of total (equation omitted)-radioactivity, $^{134,137}$Cs which is composed of more than 85 % of total ${\gamma}$-radioactivity could be fixed effectively by the PVA-PMAA solution.

  • PDF

Gallium(III) Ion Hydrolysis under Physiological Conditions

  • Hacht, Brahim
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.372-376
    • /
    • 2008
  • The hydrolysis of gallium(III) has been studied using potentiometric techniques under physiological conditions of temperature 37 C and ionic strength 0.15 moldm-3 NaCl and at different metal ion concentrations. Changes in pH were monitored with a glass electrode calibrated daily in hydrogen ions concentrations. The titration data within the pH range of 2.5-9.99 were analyzed to determine stability constants of hydroxide species using the SUPERQUAD program. Several different species were considered during the calculation procedure and the following hydroxides have been characterized: Ga(OH)3, Ga(OH)4- Ga3(OH)112-, Ga4(OH)11+ and Ga6(OH)153+. Speciation calculations based on the determined constants were then used to simulate the species distribution.