• Title/Summary/Keyword: Potentiometric

Search Result 239, Processing Time 0.029 seconds

Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients (수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발)

  • Kim, G.;Lee, S.B.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.5
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

GROUNDWATER RECHARGE ESTIMATION USING ARCGIS-CHLORIDE MASS BALANCE APPROACH

  • Lee Ju Young;Krishinamurshy Ganeshi
    • Water Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.31-38
    • /
    • 2005
  • Groundwater recharge is defined in an addition of water to groundwater reservoir. Recently, many people have been moving to the Edwards aquifer and urban and agricultural industry have been expending. Hydrologists and water planning managers concern about insufficient groundwater amounts and irrigation water price variability. In this paper, I focus on estimates of local recharge volumes and quantify preferential flow through GIS technique. Chloride Mass Balance (CMB) and hydrochemical components have been widely applied to recharge rate and evaluate flow paths. The CMB method is based on relationship between wet-dry chloride deposition data and Rainfall data. These data are manipulated using ArcGIS. Especially, hydrochemical concentration distribution is good index for groundwater residence times or flow paths such as $[Mg^{2+}]/[Ca^{2+}],[Cl]$ and log$([Ca^{2+}]+[Mg^{2+}])/[Na^+]$. Well information such as hydrological-hydrochemical data are imported into ArcGIS and manipulated by interpolation techniques. For each potentiometric surface and water quality, point data are converted to spatial data through each Kriging and Inverse Distance Weighted (IDW) techniques.

  • PDF

The Stability Constants of Lead Acetato Complexes as Function of Temperature and Ionic Strength (Pb-Acetato Complexes의 이온强度 및 溫度 變化에 따른 安定度常數에 關한 考察)

  • JUNG UI HWANG;YUNG JOO JUN
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 1967
  • The stability constants of lead acetato conplexes were evaluated in various ionic strengths (2.00, 1.00, and 0.75), and at various temperature (15, 20, 25, 30, and $35^{\circ}C$), respectively, by the polarographic and potentiometric method of which Hume and Leden had described. The existence of three complex ions, $PbAc^+$, $PbAc_2$, and $PbAc_3^-$ have been shown in the range of concentration of 0~0.8 mole acetate ion. Referring to values obtained, we have derived the following empirical formula with the stability constant (Kijk), ternperature (Tk) and ionic strength (${\mu}j$). log Kijk = (Ai/${\mu}j^3$+ Bi) / Tk + Ci/${\mu}j^3$ + Di . The deduced and observed stability constants are matched in 5% for the K, and $K_3$, and 20% for the $K_2$.

  • PDF

The Interaction between Hexadecyltrimethylammonium Bromide to Poly (Ethylene Glycol) with Different Molecular Weights and Some Schiff-Bases Investigated by Surfactant Ion Selective Electrode

  • Ghoreishi, Sayed Mehdi;Naeimi, Hossein;Navid, Mohammad Davodi
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.548-552
    • /
    • 2005
  • The interaction between ionic surfactants and different nonionic molecules and polymers are studied using ion surfactant selective electrode. From the experimental data, critical concentrations of the interaction and binding process are evaluated. The interaction between hexadecyltrimethylammonium bromide (HTAB) with polyethylene glycol (PEG) in three molecular weights (1000, 10000 and 100000) and also schiff-bases, 2-[2-carboxyphenyl nitrilomethylidyne]-phenol (ortho CNP), 2-[3-carboxyphenyl nitrilomethylidyne]-phenol (meta CNP)and 2-[4-carboxyphenyl nitrilomethylidyne]-phenol (para CNP) with the potentiometric method were investigated using HTAB membrane selective electrode. In the case of PEG with increasing molecular weights more interaction to HTAB occurs. The electromotive force (EMF) data also showed that interaction between para CNP with HTAB is more than the other schiff-bases. It seems this case related to less space interference of COOH group for that compound. The onset of binding ($T_1$) of course is the same for three schiffbase molecules.

Salicylate-Selective Electrodes Based on Tripodal Tris-thiourea Derivatives

  • Lee, Chaeg-Yeong;Kim, Jung-Hwan;Kim, Dong-Wan;Lee, Shim-Sung;Kim, Jin-Eun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2466-2470
    • /
    • 2007
  • A new highly salicylate-selective PVC membrane electrode based on tripodal tris-thiourea derivatives, L1 and L2, as neutral carriers is described. The electrodes display an excellent potentiometric response to salicylate ions and an anti-Hofmeister selectivity sequence in the following order: Salicylate? > ClO4 ? > Benzoate? > I? >NO3? > NO2? > Maleate? > Acetate? > Lactate? > Fumarate?. It also exhibited a near-Nernstian potential in a linear range of 5.0 × 10?5 - 1.0 × 10?1 M with a detection limit of 9.0 × 10?5 mol/L and a slope of ?59.9 mV/decade at a pH of 7.0 in a saline buffer solution at 25 oC. The stability constant (log KS) of the anionsionophore complex was also determined at 25 oC by a conductometric titration in DMSO solution.

Improvement of Sensing Performance on Nasicon Amperometric NO2 Sensors (나시콘 전류검출형 NO2 센서의 성능개선)

  • Kim, Gwi-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.912-917
    • /
    • 2007
  • Many electrochemical power devices such as solid state batteries and solid oxide fuel cell have been studied and developed for solving energy and environmental problems. An amperometric gas sensor usually generates sensing signal of electric current along the proportion of the concentration of target gas under the condition of limiting current. For narrow variations of gas concentration, the amperometric gas sensor can show higher precision than a potentiometric gas sensor does. In additional, cross sensitivities to interfering gases can possibly be mitigated by choosing applied voltage and electrode materials properly. In order to improve the sensitivity to $NO_2$, the device was attached with Au reference electrode to form the amperometric gas sensor device with three electrodes. With the fixed bias voltage being applied between the sensing and counter electrodes, the current between the sensing and reference electrodes was measured as a sensing signal. The response to $NO_2$ gas was obviously enhanced and suppressed with a positive bias, respectively, while the reverse current occurred with a negative bias. The way to enhance the sensitivity of $NO_2$ gas sensor was thus realized. It was shown that the response to $NO_2$ gas could be enhanced sensitivity by changing the bias voltage.

The Molybdate-Sensing Electrodes (Molybdate 이온 感應 電極)

  • Ihn, Gwon-Shik;Lee, Jung-Hwa;Min, Tae-Won
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.238-243
    • /
    • 1984
  • Three component $Ag_2S-PbS-PbMoO_4$ electrodes have been prepared and evaluated for sensitivity to molybdate. The 64.5 : 14.0 : 21.5(w/w%) composition is superior in terms of potentiometric response, stability, rapidity of response and reproducibility. Testing was done over the concentration range of $10^{-1}{\sim}10^{-5}M\;MoO_4^{2-}\;in\;0.1F\;NH_4Ac-NH_4OH$ buffer solution at pH 7.95 with constant ionic strength. $I^-,\;Cl^-,\;Br^-\;and\;CN^-$, etc. interfere.

  • PDF

Studies on the Synthesis and Structure of Macrocyclic Complexes for Transition Metals. (Part 1) Effects of Stability Constant on the Co-formation of Mixed Chelates (EDTA and IMDA) with Lanthanon (La, Nd, Gd, Ho, Yb) (전이금속 착물들의 합성 및 결정구조 연구 (제 1 보) EDTA 와 IMDA 복합 킬레이트가 란탄족 원소들 (La, Nd, Gd, Ho, Yb)의 안정도 상수에 미치는 영향)

  • Young-Gu Ha;E. Y. Kim;Q. Won Choi;Hasuck Kim
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.434-443
    • /
    • 1987
  • The formation constants of the complexes between Ln-EDTA 1 : 1 complex and IMDA have been investigated by a potentiometric titration method at 20.0${\pm}$0.2 degree C and ${\mu}$ = 0.1 (KNO$_3$). Unusually large stability in Ln(EDTA) mixed ligand complexes was found. Trends in the formation constants vs. atomic number of the lanthanide metals were discussed on the basis of coordination number and ionic radius of the metals.

  • PDF

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.

The Development of Arginine-Selective Membrane Electrode Using Tissue Slices of the Rose of Sharon (무궁화꽃을 이용한 L-Arginine Sensor 開發에 關한 硏究)

  • Kim Ui-Rak;Nam Ki-jae;Choi Sung-Moon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.753-759
    • /
    • 1992
  • It is shown that receptacle tissue of the rose of sharon can serve as an effective biocatalyst by the construction of a potentiometric membrane electrode with response and selectivity for arginine. Electrodes using this tissue in conjunction with $NH_3$ gas sensing probes yield good response to arginine in $10^{-1}M to 10^{-3}M$ range and retain activity for a least 1 weeks. The arginine-selective membrane electrode using tissue slices of the rose of sharon have good selectivity in presence of other amino acids. The optimum conditions are pH 8.0, $25^{\circ}C$ and $20 {\mu}m$ thickness of slices in 0.1 M phosphate buffer solution and $K_m$ values is $6.4 {\times} 10^{-6}(M)$.

  • PDF