• 제목/요약/키워드: Potentiodynamic method

검색결과 84건 처리시간 0.023초

알루미늄 6061 합금 양극산화 후 열처리에 따른 표면 특성 관찰 (Effects of Heat Treatment on Surface Properties of Aluminum 6061 Alloy After Anodization)

  • 이승민;정찬영
    • Corrosion Science and Technology
    • /
    • 제21권6호
    • /
    • pp.495-502
    • /
    • 2022
  • Anodization is a representative electrochemical surface treatment method that can improve both heat resistance and corrosion resistance by forming an anodization film on the surface of the aluminum. However, these properties can be changed after an additional heat treatment process. In this study, Al 6061 was subjected to an anodization process at 60 V for 1 hour, 5 hours, or 9 hours. An additional heat treatment process was performed at 500 ℃ for 30 minutes. Field emission scanning electron microscopy (FE-SEM) analysis revealed that the thickness of the anodized film was increased in proportion to the anodization time. Both pore size and pore diameter of the anodized film was also increased after anodization. After an additional heat treatment process, there were no significant changes in the thickness, pore size, or pore diameter of the anodized film. Heat resistance was confirmed through thermal analysis and chemical resistance was evaluated with a potentiodynamic polarization test.

스프링클러 구리배관의 공식 파손 억제 (Inhibition of Pitting Corrosion Failure of Copper Tubes in Wet Sprinkler Systems)

  • 서상희;서영준;이종혁;권혁상
    • Corrosion Science and Technology
    • /
    • 제19권2호
    • /
    • pp.89-99
    • /
    • 2020
  • The inhibition of pitting corrosion failure of copper sprinkler tubes in wet sprinkler systems was studied. First, an apparatus and technology for removing air in the sprinkler tubes by vacuum pumping and then filling the tubes with water were developed. Using this apparatus and technology, three methods for inhibiting the pitting corrosion of the copper sprinkler tubes installed in several apartment complexes were tested. The first one was filling the sprinkler tubes with water bubbled by high-pressure nitrogen gas to reduce the dissolved oxygen concentration to lower than 2 ppm. In the second method, the dissolved oxygen concentration of water was further reduced to lower than 0.01 ppm by sodium sulfite. In the third method, the sprinkler tubes were filled with benzotriazole (BTAH) dissolved in water. The third method was the most effective, reducing the failure frequency of the sprinkler tubes due to pitting corrosion by more than 80%. X-ray photoelectron spectroscopy analyses confirmed that a Cu-BTA layer was well coated on the inside surface of the corrosion pit, protecting it from corrosion. A potentiodynamic polarization test showed that BTAH should be very effective in reducing the corrosion rate of copper in the acidic environment of the corrosion pit.

A Study on the Crevice Corrosion for Ferritic Stainless Steel by Micro Capillary Tube Method

  • Na Eun-Young;Ko Jae-Yong;Baik Shin-Young
    • 전기화학회지
    • /
    • 제7권4호
    • /
    • pp.179-182
    • /
    • 2004
  • The aim of this study is to investigate the initiation and propagation of crevice corrosion for ferritic stainless steel in artificial crevice based on micro capillary tube method. The 430 stainless steel in artificial crevice is potentiostatically polarized in different sodium chloride solutions. Potentiodynamic and potentiostatic polarization data were measured in situ. The potentials in the crevice were measured by depth profile using the 0.04 mm diameter micro capillary tube inserted in the crevice. The potentials in the crevice ranged from -220 mV to -360 mV vs SCE from opening to bottom of crevice, which are lower than the external surface potential, -200 mV vs SCE. Such a potential drop induced the change of the metal surface state from passive to active. The surface of metal is located in passive state in -200 mV but the inner surface keeps active state below -220 mV, Thus these results show that the It drop mechanism in the crevice was more objective for evaluation and the method was easier to reproduce. Therefore the potential drop is one of the reasons for crevice corrosion by measuring the potentials in narrow crevice with a new micro measuring system.

용융탄산염 연료전지 양극용 다공성 cermet 전극제조에 관한 연구 (A study on the fabrication of porous cermet electrode for molten carbonate fuel cell anode)

  • 이규환;장도연;김만;강성군
    • 한국표면공학회지
    • /
    • 제26권6호
    • /
    • pp.291-298
    • /
    • 1993
  • In order to substitute for porous nickel anode in Molten Carbonate Fuel Cell(MCFC), porous cermet elec-trode was fabricated with Ni and Ni-P coated ceramic powder. Ni and Ni-P were coated by electroless plat-ing method in the nickel solution containing of hydrazine and sodium hypophosphate as a reducing agent. The plating solution was stirred by air and mechanical agitator. Ultrasonic irradiation was applied to the plating bath to improved the effect of agitation and coating speed. Electorde was formed by pressing method and doc-tor blade method followed by sinterd at$ 800^{\circ}C$ for 6 hours in H2 environment. Anode performance test carried out by potentiodynamic polarization technique in the MCFC operating condition and 154-161mA/$\textrm{cm}^2$ as ob-tained as a anode current density at the+100mV overpotential.

  • PDF

주조 방식 및 압연에 따른 연축전지용 납 합금 기판의 부식 특성 (Effects of Casting Method and Rolling on the Corrosion Behaviors of Pb Alloys for a Lead Acid Battery)

  • 오꽃님;이규혁;장희진
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.315-323
    • /
    • 2021
  • In this study, we examined corrosion behaviors of two types of Pb alloys for a lead acid battery comparatively. One containing 6.6 wt% Sn, 36 mg/kg Bi, and 612.4 mg/kg Ca was prepared by twin-roll continuous casting. The other containing 5.2 wt% Sn, 30.5 mg/kg Ag, and 557 mg/kg Ca was made by twin-belt continuous casting. Potentiodynamic polarization tests were performed to evaluate corrosion resistance. Cyclic voltammetry was done to examine oxidation and reduction reactions occurring on the surface of each alloy in 4.8 M H2SO4 solution. Electrochemical test results implied that the Pb alloy prepared with the twin-belt casting method was less stable than that cast with the twin-roll method. Such results might be due to precipitations formed during the casting process. Rolling did not appear to affect the corrosion behavior of the twin-roll samples with Ag < 10 mg/kg, while it reduced the anodic reaction of Ag on the surface of the twin-belt sample with 30.5 mg/kg Ag.

알루미늄 기지 자동차에 쓰이는 탄소강 리벳과 그라파이트간의 갈바닉 부식 방지 연구 (Study on Prevention of Galvanic Corrosion between Carbon Steel Rivets and Graphite Used in Aluminum Matrix Automobiles)

  • 서동일;이재봉
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.128-140
    • /
    • 2017
  • Aluminum alloy matrix may be used for manufacturing lighter automobiles. However, galvanic corrosion may occur between the rivet joint combining aluminum alloy matrix and a CFRP (carbon fiber reinforced plastic) laminate. The possibility of galvanic corrosion may be investigated by measuring galvanic couple currents. Two types of galvanic current measuring methods were used. One method is to use potentiodynamic polarization curves and the other is the ZRA (zero resistance ammeter) method. For galvanic corrosion experiments graphite, a major component of CFRP, was used with carbon steel (rivets) and 6061 aluminum alloys. Regardless of carbon steel, Ni deposited carbon steel, and 316L stainless steels we also investigated the possibility of reduction in galvanic corrosion. Results revealed that even though Ni deposited carbon steel or 316L stainless rivet may slightly increase galvanic current density between those and Al matrix, substitute rivets for carbon steel may be considerably useful for reducing overall galvanic corrosion.

NaCl 수용액내의 양성자와 디이소부틸니트로소아민의 치환흡착과 열역학적 특성 (Substitutional Adsorption and Thermodynamic Characteristics of Proton and Di-iso-butylnitrosoamine in NaCl Aqueous Solution)

  • 황금소
    • 한국수산과학회지
    • /
    • 제16권3호
    • /
    • pp.239-245
    • /
    • 1983
  • Electrochemical adsorption always was accompanied with solvent displacement and relative size factor(x) of adsorbate and solvent and hydrogen coverage(${\theta}$) on the lead anodic film electrode formed in phosphoric acid in NaCl solution and the sea water at $15{\sim}35^{\circ}C$ were studied by means of constant current-potential method and potentiodynamic cathodic polarization method. In this experiment, various constants and thermodynamic quantities calculated from the hydrogen coverage were also described to explain the reactivities of di-iso-butylnitrosoamine(DBNA) and proton ($H^+$) according to the changes of interactions between solute and solvent in the bulk phase and interphase. It was investigated that the average values of relative size factor and the coverage of hydrogen atoms studied with the electrode of lead anodic film formed in phosphoric acid solution in 60mM DBNA+0.5M NaCl and in 60mM DBNA+$6\%0$ sea water were about 11.0 and 0.2 respectively. Hydrogen evolution was electrochemical mechanism because of substitutional adsorption of aromatic substance with their delocalization of electrons, but in the case of non-charge transfer adsorption of aliphatic substance(DBNA) interacting relatively little with the electrode, it was combination mechanism.

  • PDF

Corrosion Inhibition of Steel for Water Pipe Line by Adding a Non-Toxic Spearmint Extracts

  • Farooq, Hina;Kim, Jae-Yeon;Lee, Do-Il;Byeon, Jai-Won
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권2호
    • /
    • pp.122-128
    • /
    • 2017
  • Purpose: To investigate the corrosion inhibition effect of the natural spearmint oil extracted from Mentha Spicata plants on 304 stainless steel in different concentrations of hydrochloric acid. Method: The anti-corrosive effect has been investigated in 0.5m, 1m and 2m HCl using weight loss test and electrochemical polarization method as a function of inhibitor concentration and immersion time in strong chloride environment. The surface morphology was analysed by scanning electron microscopy (SEM). Results: The corrosion rate of steel decreased and inhibition efficiency increased with the increase in inhibitor concentration. Microscopic evaluation revealed significant corrosion in the specimens immersed in uninhibited conditions. Potentiodynamic polarization test results showed an increase in corrosion potential (Ecorr) and decrease in corrosion current (icorr) value with increasing concentration of inhibitor. Conclusions: Immersion of steel in higher concentration of inhibitor resulted in greater surface coverage value and hence lesser number of surface corrosion sites/pores were formed; thus lowering the corrosion rate.

탄소강의 부식에 미치는 아민계 용액의 조건에 관한 연구 (A Study on Local Conditions in Amine Solutions Influencing on Corrosion of Carbon Steel)

  • 권혁준;안현경;송찬호;박병기;조대철;이인형
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2879-2887
    • /
    • 2011
  • 본 연구는 탄소강 재질의 증기발생기 배관에서 수화학 조건에 따라 발생하는 부식현상의 이해와 부식속도 측정을 위한 것이다. 부식을 최소화하기 위하여 염기 및 환원성 분위기 유지가 중요하나, 계통재질에 따라 pH 및 산화환원 전위가 다르고, pH제어제의 종류에 따라 부식의 정도가 다르게 나타난다. 실험에는 pH제어제로서 ETA 와 전통적 NH3를 사용하였다. 본 연구에서는 pH 8.5~10, 온도 $50\sim250^{\circ}C$의 조건에서 동전위 분극 부식시험(potentiodynamic polarization)을 통해 부식전류밀도(corrosion current density)를 구하여 부식율(corrosion rate)을 계산하였다. 부식시험 결과, $NH_3$ 보다 ETA 용액에서 부식율이 낮고, pH 증가시 부식율이 감소하였으며, $150\sim200^{\circ}C$범위의 온도에서 부식율이 최대로 나타났다.

TiN 및 WC코팅된 치과용 어버트먼트 나사의 안정성 (Stability of TiN and WC Coated Dental Abutment Screw)

  • 손미경;이충환;정재헌;정용훈;최한철
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.292-300
    • /
    • 2008
  • Dental implant system is composed of abutment, abutment screw and implant fixture connected with screw. The problems of loosening/tightening and stability of abutment screw depend on surface characteristics, like a surface roughness, coating materials and friction resistance and so on. For this reason, surface treatment of abutment screw has been remained research problem in prosthodontics. The purpose of this study was to investigate the stability of TiN and WC coated dental abutment screw, abutment screw was used, respectively, for experiment. For improving the surface characteristics, TiN and WC film coating was carried out on the abutment screw using EB-PVD and sputtering, respectively. In order to observe the coating surface of abutment screw, surfaces of specimens were characterized, using field emission scanning electron microscope(FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The stability of TiN and WC coated abutment screw was evaluated by potentiodynamic, and cyclic potentiodynamic polarization method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion potential of TiN coated specimen was higher than those of WC coated and non-coated abutment screw. Whereas, corrosion current density of TiN coated screws was lower than those of WC coated and non-coated abutment screw. The stability of screw decreased as following order; TiN coating, WC coating and non-coated screw. The pitting potentials of TiN and WC coated specimens were higher than that of non-coated abutment screw, but repassivation potential of WC coated specimen was lower than those of TiN coated and non-coated abutment screws due to breakdown of coated film. The degree of local ion dissolution on the surface increased in the order of TiN coated, non-coated and WC coated screws.