• 제목/요약/키워드: Potential Transformer

검색결과 123건 처리시간 0.03초

고전압 초전도 변압기용 연속 디스크 권선의 특성 해석 (Characteristics of a Continuous Disk Winding for High Voltage HTS Transformer)

  • 황영인;이승욱;김우석;최경달
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.295-300
    • /
    • 2007
  • High temperature superconducting (HTS) windings for an HTS transformer which have been developed have two kinds of type, one is the layer winding and the other is disk winding. The layer winding has adopted for an HTS power transformer so far because of the small AC losses of the HTS windings. The disk windings have surface of the HTS wire. We propose a new winding method for a high voltage HTS transformer which has advantages of both type of HTS windings, and we call it continuous disk winding. This new HTS winding consists of pile of HTS disk windings. The continuous disk winding was fabricated with multi-stacked HTS wires for dover HTS transformer. We can check the potential possibility from the characteristic test of the fabricated winding. The new type HTS windings can be applied to HTS power transformers, especially to the high voltage ones.

몰드형 건식 계기용 변압기 진동 특성 분석 (Analysis of Vibration Characteristics for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.209-214
    • /
    • 2017
  • 현재 철도 차량에 쓰이고 있는 대부분의 계기용 변압기는 장치 내부에 절연유가 충진되어 있는 유입식 계기용 변압기 방식으로서, 내구 연한 도래와 더불어 차량 운행 중 내부 압력 상승에 의해 폭발의 위험성이 있다. 이에 대한 해결책으로 절연 수지를 사용하여 방압 기능이 탁월한 몰드형 건식 계기용 변압기 개발이 필요하다. 이에 제품의 국산화가 가능하도록 한국철도기술연구원에서는 몰드형 건식 계기용 변압기를 개발 진행 중에 있다. 그 연구의 일환으로 개발 제품의 진동 특성 분석과 함께, 진동 환경하에서 변압기의 성능 유지 여부를 확인하여야 한다. 이번 연구에서는 철도 차량 부품의 진동 시험 방법 규격인 KS R 9144 및 IEC 61373 에 따라서 개발 제품의 공진시험과 모의 장기 수명 시험을 진행하였다. 고유 진동수는 해석을 통한 모달 분석과 공진 시험을 병행하여 결과를 비교 분석하였으며 규격 조건을 만족함을 확인하였다. 또한 모의 장기 수명 시험 후 성능 시험을 통해 오랜 시간 진동 환경 하에서도 개발 변압기의 기능에 문제가 없음을 확인하였다.

가스절연개폐장치의 스페이서 내장형 전자식 변압기의 설계 및 제작 (Design and Fabrication of an Electronic Voltage Transformer (EVT) Embedded in a Spacer of Gas Insulated Switchgears)

  • 임승현;김남훈;김동언;김선규;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.353-358
    • /
    • 2022
  • Bulky iron-core potential transformers (PT) are installed in a tank of gas insulated switchgears (GIS) for a system voltage measurement in power substations. In this paper, we studied an electronic voltage transformer (EVT) embedded in a spacer for miniaturization, eco-friendliness, and performance improvement of GIS. The prototype EVT consists of a capacitive probe (CP) that can be embedded in a spacer and a voltage Follower with a high input and a low output impedance. The CP was fabricated in the form of a Flexible-PCB to acquire the insulation performance and to withstand vibration and shock during operation. Voltage ratio of the prototype EVT is about 42,270, and the frequency bandwidth of -3 dB ranges from 0.33 Hz to 3.9 MHz. The voltage ratio error evaluated at about 6%, 12% and 18% of the rated voltage of 170 kV was 0.32%, and the phase error was 12.9 minutes. These results were within the accuracy for the class 0.5 specified in IEC 60044-7 and satisfy even in ranges from 80% to 120% of the rated voltage. If the prototype EVT replaces the conventional iron-core potential transformer, it is expected that the height of the GIS could be reduced by 11% and the amount of SF6 will be reduced by at least 10%.

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

유압 트랜스포머를 이용한 에너지 절감형 유압시스템에 관한 기초연구 (A study on Energy Saving Hydraulic System Using Hydraulic Transformer)

  • 이민수;안경관;조용래;조우근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.917-922
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. Based on the nominal model derived from mathematical model, the feedback type two-degree-of-freedom controller is designed and implemented. From simulation results, the disturbances including nonlinear friction torque, leakage flow and load force can be compensated and good positioning accuracy is obtained. It show that the proposed controller is effective.

  • PDF

초소형 마이크로 압전변압기 제작 및 특성 분석 (Fabrication and Characteristic Analysis of Piezoelectric Micro-Transformer)

  • 김성곤;서영호;최두선;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.469-470
    • /
    • 2006
  • Piezoelectric transformers based on lead zirconate titanate(PZT) have been received considerable interest because of their wide potential applications in transformer, oscillator, resonance sensor, actuator, acoustic transducer, as well as active slider for hard disk drives. However, for the applications which need a small power supply such as thin and flat displays, micro-robot, micro-system, it is especially necessary to integrate the passive components because they typically need more than 2/3 of the space of the conventional circuit. So, we have fabricated the piezoelectric micro-transformer to supply energy for micro-systems using PZT thin films and MEMS technologies.

  • PDF

광센서에 의한 전류전압 측정법 (Current and Voltage Measurement using Optical Sensors)

  • 김영수;박해수;김관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.523-526
    • /
    • 1987
  • The present metering transformer being used for measurement has the characteristics of high reliability and high efficiency. In the future, however, it is thought that the scales of mettering transformer will be larger and the cost of production will increase as the transmission voltage ascends to UHV. And, also, it wilt be not easy to ensure the aseismatic capability. For the purpose of settling these problems, by applying optical sensor technology to electric power systems and by developing optical current transformer and potential transformer, we will realize the saving in energy, reduction of cost prise, improvement in measuring precision.

  • PDF

주상변압기의 열화진단을 위한 원격측정 (The Deterioration Diagnosis of pole Transformer using Remote Measurement)

  • 송현선;이상돈
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 논문에서 제안한 주상변압기 열화진단 장치는 활선 상태에서 변압기 외함온도, 2차전류 및 누설전류 등을 측정하고, 지정값 이상의 상태가 발생하면 변압기 관리자에게 유선 및 이동통신기를 통하여 자동통보함으로써 사고를 사전에 예방할 수 있다. 또한 무선데이터통신을 이용하여 수집된 정보를 분석하고 각 상별 전류분포, 이용률 및 온도변화 추이를 그래프로 나타냄으로서 각 상별 부하의 불평형 정도와 변압기의 열화 추이 상태를 파악할 수 있다. 실계통 실험을 통하여 제안한 주상 변압기 열화 진단 장치의 효용성을 입증하였다.

An Ensemble Model for Credit Default Discrimination: Incorporating BERT-based NLP and Transformer

  • Sophot Ky;Ju-Hong Lee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 춘계학술발표대회
    • /
    • pp.624-626
    • /
    • 2023
  • Credit scoring is a technique used by financial institutions to assess the creditworthiness of potential borrowers. This involves evaluating a borrower's credit history to predict the likelihood of defaulting on a loan. This paper presents an ensemble of two Transformer based models within a framework for discriminating the default risk of loan applications in the field of credit scoring. The first model is FinBERT, a pretrained NLP model to analyze sentiment of financial text. The second model is FT-Transformer, a simple adaptation of the Transformer architecture for the tabular domain. Both models are trained on the same underlying data set, with the only difference being the representation of the data. This multi-modal approach allows us to leverage the unique capabilities of each model and potentially uncover insights that may not be apparent when using a single model alone. We compare our model with two famous ensemble-based models, Random Forest and Extreme Gradient Boosting.

마스크된 복원에서 질병 진단까지: 안저 영상을 위한 비전 트랜스포머 접근법 (From Masked Reconstructions to Disease Diagnostics: A Vision Transformer Approach for Fundus Images)

  • ;변규린;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.557-560
    • /
    • 2023
  • In this paper, we introduce a pre-training method leveraging the capabilities of the Vision Transformer (ViT) for disease diagnosis in conventional Fundus images. Recognizing the need for effective representation learning in medical images, our method combines the Vision Transformer with a Masked Autoencoder to generate meaningful and pertinent image augmentations. During pre-training, the Masked Autoencoder produces an altered version of the original image, which serves as a positive pair. The Vision Transformer then employs contrastive learning techniques with this image pair to refine its weight parameters. Our experiments demonstrate that this dual-model approach harnesses the strengths of both the ViT and the Masked Autoencoder, resulting in robust and clinically relevant feature embeddings. Preliminary results suggest significant improvements in diagnostic accuracy, underscoring the potential of our methodology in enhancing automated disease diagnosis in fundus imaging.