• Title/Summary/Keyword: Potential Peak

Search Result 845, Processing Time 0.029 seconds

Analysis of Meridians Potential as Ground Condition for Objectification of Acupuncture Effect (침술 효과의 객관화를 위한 접지조건에 따른 경락전위분석)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.436-441
    • /
    • 2007
  • Background: As patients are positioned at insulated bed and practitioner are positioned at insulated floor or shoes, it could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. Method: We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground, respectively. Result: All ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. practitioner ground only showed negative mean potential $-51.5{\pm}9.3{\mu}V\;and\;367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential as $2.9{\pm}1.3{\mu}V,\;16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential as $1.6{\pm}0.7{\mu}V,\;3.3{\pm}1.9{\mu}V$ of peak to peak potential. respectively.

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

Trapezoidal Cyclic Voltammetry as a Baseline for Determining Reverse Peak Current from Cyclic Voltammograms

  • Carla B. Emiliano;Chrystian de O. Bellin;Mauro C. Lopes
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.405-413
    • /
    • 2024
  • Several techniques for determining the reverse peak current from a cyclic voltammogram (CV) for a reversible system are described in the literature: CV itself as a baseline with long switching potential (Eλ) that serves as a baseline for other CVs, Nicholson equation that uses CV parameters to calculation reverse peak current and linear extrapolation of the current obtained at the switching potential. All methods either present experimental difficulties or large errors in the peak current determination. The paper demonstrates, both theoretically and experimentally, that trapezoidal cyclic voltammetry (TCV) can be used as a baseline to determine anodic peak current (iap) with high accuracy and with a switching potential shorter than that used by CV, as long as Eλ is at least 130 mV away from the cathodic peak. Beyond this value of switching potential the electroactive specie is completely depleted from the electrode surface. Using TCV with Eλ = 0.34 V and a switching time (tλ) of 240 s as a baseline, the determination of the reverse peak current presents a deviation from the expected value of less than 1% for most of the CVs studied (except cases when Eλ is close to the direct potential peak). This result presents better accuracy than the Nicholson equation and the linear extrapolation of the current measured at the switching potential, in addition to presenting a smaller error than that obtained in the acquisition of the experimental current. Furthermore, determining the reverse peak current by extrapolating the linear fit of iap vs. ${\sqrt[1/]{t_{\lambda}}}$ to infinite time gave a reasonable approximation to the expected value. Experiments with aqueous potassium hexacyanoferrate (II) and ferrocene in acetonitrile confirmed the theoretical predictions.

Study of Peak Load Demand Estimation Methodology by Pearson Correlation Analysis with Macro-economic Indices and Power Generation Considering Power Supply Interruption

  • Song, Jiyoung;Lee, Jaegul;Kim, Taekyun;Yoon, Yongbeum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1427-1434
    • /
    • 2017
  • Since the late 2000s, there has been growing preparation in South Korea for a sudden reunification of South and North Korea. Particularly in the power industry field, thorough preparations for the construction of a power infrastructure after reunification are necessary. The first step is to estimate the peak load demand. In this paper, we suggest a new peak demand estimation methodology by integrating existing correlation analysis methods between economic indicators and power generation quantities with a power supply interruption model in consideration of power consumption patterns. Through this, the potential peak demand and actual peak demand of the Nation, which experiences power supply interruption can be estimated. For case studies on North Korea after reunification, the potential peak demand in 2015 was estimated at 5,189 MW, while the actual peak demand within the same year was recorded as 2,461 MW. The estimated potential peak demand can be utilized as an important factor when planning the construction of power system facilities in preparation for reunification.

Semi-Circular Potential Sweep Voltammetry: Electrochemically Quasi-Reversible System

  • Park, Kyungsoon;Hwang, Seongpil
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.379-383
    • /
    • 2020
  • The novel voltammetry using a semi-circular potential wave for quasi-reversible charge transfer system on electrode is theoretically investigated. Compared with conventional voltammetry based on linear sweep such as linear sweep voltammetry (LSV), semi-circular potential sweep voltammetry (SCV) may decrease the charging current outside the center of potential range and increase the faradaic current at the midpoint due to variable scan rate. In this paper, we investigate the system based on macroelectrode where simple 1 dimensional (1 D) diffusion system is valid with various charge transfer rate constant (k0). In order to observe the amplification at midpoint, voltammetric response with different midpoint ranging from -200 mV to 200 mV are studied. SCVs shows both the shift of peak potential and the amplification of peak current for quasi-reversible electrode reaction while only higher peak current is observed for reversible reaction. Moreover, the higher current at midpoint enable the amplification of current at low overpotential region which may assist the determination of onset potential as a figure-of-merit in electrocatalyst.

Sulfur Redox Equilibrium in Mixed Alkali Silicate Glass Melts

  • Kim, Ki-Dong;Hwang, Jong-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.205-210
    • /
    • 2011
  • The dependence of sulfur redox behavior and its diffusivity on temperature and composition was studied in mixed alkali silicate melts by means of square wave voltammetry (SWV) at different frequencies in a temperature range of $1000^{\circ}C$ to $1400^{\circ}C$. The voltammograms showed two reduction peaks at high frequency but only one peak at low frequency. Irrespective of $K_2O/(Na_2O+K_2O)$, each peak potential due to reduction of $S^{6+}$ to $S^{4+}$ and $S^{4+}$ to $S^0$ moved toward a negative direction with temperature decrease, and the peak current showed a strong dependence on frequency at a constant temperature. However, the compositional dependence of the peak potential showed an inconsistent behavior with an increase of $K_2O$. The mixed alkali effect was not observed in sulfur diffusion. This inconsistency of both peak potential and diffusion for compositional dependence may be derived from the strong volatilization of sulfur in melts.

Studies on the Active Materials of Alkaline Storage Battery. On Cadmium Electrode (알칼리 축전지의 활물질에 관한 연구. 카드뮴 전극에 관하여)

  • Ju Seong Lee;Choong Yeoul Joo;Park, Su Gil
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.325-330
    • /
    • 1981
  • The electrochemical behavior of cadmium electrode for the nickel-cadmium battery system has been studied by cyclic voltammetry, controlled potential electrolysis and X-ray diffraction method. Cathodic polarization curve for cadmium hydroxide electrode prepared by electrochemical pretreatment of metallic cadmium showed two peaks. It has been found that cadmium hydroxide was reduced to cadmium metal at the first peak potential, whereas very activated metal of cadmium which was strongly oriented (002) rather than (101) was formed at the second peak potential. It was also found that the cadmium formed at the second peak potential reacted rapidly with oxygen. Therefore, it could be presumed that the cadmium recombination reaction with the oxygen was chemical, and could be represented as $2Cd + O_2 + 2H_2O\;{\longrightarrow}\;2Cd(OH)_2$.

  • PDF

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

Effects of Ginseng Extract on Excitable Cell Membrane Potential (인삼추출물이 흥분성세포의 막전압에 미치는 영향)

  • Chung, Jin-Mo;Paik, Kwang-Se;Nam, Taick-Sang;Kim, In-Kyo;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.3-8
    • /
    • 1981
  • Studies have been conducted to test the effect of Ginseng alcohol extract on the membrane potentials of frog skeletal muscle. The gastrocnemius muscle was isolated and placed in a chamber containing the Clark-frog Ringer solution. Membrane potentials were recorded using microelectrodes filled with 3 M KCI and muscle was electrically stimulated to obtain action potential. Changes in both the action potential and the resting membrane potential were observed after adding an appropriate amount of Ginseng alcohol extract in the perfusing Ringer solution. The results obtained from 346 muscle cells are summarized as follows : 1) The average resting membrane potential of the normal frog gastrocnemius muscle cell was -92.8 mV and the peak of the action potential reached at 29.8 mV. 2) Both the resting membrane potential and the peak of the action potential decreased by Ginseng alcohol extract, the effect being proportional to the dose of Ginseng alcohol extract. 3) The resting membrane potential and the peak of the action potential continuously decreased until about 40 min after Ginseng addition and leveled off thereafter. The potentials recovered to its original value after Ginseng was washed out. 4) The resting membrane potential was more sensitive to the Ginseng alcohol extract than was the action potential. These results strongly suggest that Ginseng alcohol extract increases both the $Na^+$ and $K^+$ permeability in the skeletal muscle cell membrane.

  • PDF

A STUDY ON THE CORROSION OF AMALGAMS IN CHLORIDE SOLUTION (Chloride용액에서의 아말감부식에 대한 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.502-514
    • /
    • 1998
  • The purpose of this study is to observe the corrosion characteristcs of four dental amalgams(CAULK FINE CUT, CAULK SPHERICAL, DISPERSALLOY, TYTIN) and to determine a function of chloride concentration through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylinderical metal mold, and condensed by hydrolic pressure. Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 6 months. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam m KCl and KCl-NaCl solution, which had chlonde concentration of 0.4 g/l, 0.8 g/l, 1.2 gil, and 1.6 gil at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was - 1500mV ~+800mV(vs. S.C.E.) in the working electrode and the scan rate was 50mV/sec. The results were as follows, 1. The corrosion potential. the potential of anodic current peak, and transpassive potential in the solution of high chloride concentration shifted to more cathodic direction than those in the solution of low concentration, and the current density in the solution of high chloride concentration was higher than that in the solution of low concentration. 2. The corrosion potential, the potential of anodic current peak, and transpassive potential for CAULK FINE CUT amalgam were the most cathodic among the others, and the current density were the highest among the others. 3. In the solution of low chloride concentration, the corrosion potential, the potential of anodic current peak, and transpassive potential for DISPERSALLOY were the most anodic among the others, however in the solution of high chloride concentration, those for TYTIN were the most anodic among the others. 4. The anodic polarization curve for CAULK SPHERICAL was similar to that for high copper amalgams.

  • PDF