• Title/Summary/Keyword: Posterior screw fixation

Search Result 116, Processing Time 0.026 seconds

Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients (요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교)

  • Shin, Pill Jae;Kim, Chang Hyun;Moon, Jae Gon;Lee, Ho Kook;Hwang, Do Yun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

Comparison between Posterior and Transforaminal Approaches for Lumbar Interbody Fusion

  • Park, Jae-Sung;Kim, Young-Baeg;Hong, Hyun-Jong;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.340-344
    • /
    • 2005
  • Objective: Posterior lumbar interbody fusion(PLIF), the current leading method of pedicle screw fixation combined with interbody fusion via posterior route, sometimes requires too much destruction of the facet joint than expected especially for the patient with a narrow spine. On the other hand, tranforaminal lumbar interbody fusion(TLIF) technique provides potential advantages over PLIF and can be chosen as a better surgical alternative to more traditional fusion methods in certain surgical conditions. Methods: From October 1999, 99 PLIF and 29 TLIF procedures were done for the patients with spinal stenosis and instability. Radiological data including the interpedicular distance and the size of the pedicles as well as the clinical parameters were collected retrospectively. The degree of resection of the inferior articular process was compared with the interpedicular distance in each patient who received PLIF. Results: No significant differences were found between PLIF and TLIF regarding the operation time, blood loss, duration of hospital stay, or short term postoperative clinical result. There were no complication with TLIF, but PLIF resulted in 9(9.1%) complications. During PLIF procedure, all patients(n=24) except one with the interpedicular distance shorter than 27mm required near complete or complete resection of the inferior articular processes, whereas only 6(31.5%) of 19 patients with the interpedicular distances longer than 30mm required the similar extent of resection. Conclusion: TLIF is better than PLIF in terms of the complication rate. The patient who had narrow interpedicular distance(<27mm) might be better candidate for TLIF.

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Combined Anterior and Posterior Operation for Thoracic Tuberculous Spondylitis

  • Cho, Bok-Hyun;Kim, Seok-Won;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.3
    • /
    • pp.166-170
    • /
    • 2007
  • Objective : The purpose of this study is to evaluate the clinical outcome of the two-stage operation for thoracic tuberculous spondylitis. Methods : Eleven patients [4 male, 7 female] with thoracic tuberculous spondylitis were treated with two-stage operation. First stage consisted of anterior debridement and interbody fusion using rib graft and second with posterior instrumentation with fusion. Mean age was 46 years, and mean follow-up period was 18 months. All patients were treated with 12 months of antituberculotic medication postoperatively, and evaluated before and after surgery with respect to pain level, neurological status, associated lesions, hematological parameters and change of kyphotic angle. Results : The associated lesions were pulmonary tuberculosis in 4 cases. There were no recurrences of infection and bone union was obtained within 6 months of the operation in all cases. Changes in the pain severity, neurological status, and hematological parameters demonstrated significant clinical improvement in all patients. The mean kyphotic angle was corrected from $17.8^{\circ}$ to $9.8^{\circ}$ after surgery. The most recent follow-up of the mean kyphotic angle was $12.3^{\circ}$, with a loss of correction of $2.5^{\circ}$. The preoperative VAS averaged to be 7.18 [range, 4-10]. It decreased significantly an average of 1.45 [p <0001]. Conclusion : These results indicate that two-stage surgical treatment for thoracic tuberculous spondylitis provid safe and satisfactory results. Spine instability and kyphosis can be also prevented by two-stage operation.

Clinical Comparison of Posterolateral Fusion with Posterior Lumbar Interbody Fusion

  • Kim, Chang-Hyun;Gill, Seung-Bae;Jung, Myeng-Hun;Jang, Yeun-Kyu;Kim, Seong-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • Objective : The purpose of this study is to compare the outcomes of two methods for stabilization and fusion : Postero-Lateral Fusion [PLF, pedicle screw fixation with bone graft] and Posterior Lumbar Interbody Fusion [PLIF, cage insertion] for spinal stenosis and recurred disc herniation except degenerative spondylolisthesis. Methods : Seventy one patients who underwent PLF [n=36] or PLIF [n=35] between 1997 and 2001 were evaluated prospectively. These two groups were compared for the change of interbody space, the range of segmental angle, the angle of lumbar motion, and clinical outcomes by Prolo scale. Results : The mean follow-up period was 32.6 months. The PLIF group showed statistically significant increase of the interbody space after surgery. However, the difference in the change of interbody space between two groups was insignificant [P value=0.05]. The range of segmental angle was better in the PLIF group, but the difference in the change of segmental angle was not statistically significant [P value=0.0l7]. Angle of lumbar motion was similar in the two groups. Changes of Prolo economic scale were not statistically significant [P value=0.193]. The PLIF group showed statistically significant improvement in Prolo functional scale [P value=0.003]. In Prolo economic and functional scale, there were statistically significant relationships between follow-up duration [P value<0.001]. change of interbody space [P value<0.001], and range of segmental angle [P value<0.001]. Conclusion : Results of this study indicate that PLIF is superior to PLF in interbody space augmentation and clinical outcomes by Prolo functional scale. Analysis of clinical outcomes showed significant relationships among various factors [fusion type, follow-up duration, change of interbody space, and range of segmental angle]. Therefore, the authors recommend instrumented PLIF to offer better clinical outcomes in patients who needed instrumented lumbar fusion for spinal stenosis and recurred disc herniation.

The Early Result of Anterior Rotational Osteotomy in the Treatment of Osteonecrosis of the Femoral Head (대퇴골두 무혈성괴사의 치료에서 전방 회전 절골술의 조기 추시 결과)

  • Kim, Se-Dong;Shin, Duk-Seop;Jang, Woo-Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.284-292
    • /
    • 1994
  • In transtrochanteric rotational osteotomy to treat osteonecrosis of the femoral head, the necrotic superior anterior femoral head is rotated anteriorly around the longitudinal neck axis so that the weight bearing force is transferred to the intact posterior surface. The ratio of transposed intact articular surface of the femoral head to the weight-bearing surface of the acetabulum on postoperative anteroposterior view of the hip roentgenograph is the most important indicator of the prognosis. During the period from December 1992 to June 1994, we treated 31 hips in 28 patients who were indicated for the anterior rotational osteotomy among the patients of osteoncrosis of the femoral head. Among the patients, male were 27 and female was one. Age distribution was from 13 to 62 years old and mean age was 44.3. According to the Ficat and Arlet classification, II A was most in number as 16 II B was 7 and III was 8. As their etiolgic factors, alcohol was most in number as 18, steroid was 3, idiopathic was 5 and trauma was 2. The mean rate of the intact area of the posterior part of the femoral head to the total articular surface on the preoperative lateral view of the hip roentgenograph was 41.8%, The mean ratio of transposed intact articular surface of the femoral head to the weight bearing surface of the acetabulum was 53.8%, Fixation devices were screws or dynamic hip screw.

  • PDF

Collapsed L4 Vertebral Body Caused by Brucellosis

  • Ekici, Mehmet Ali;Ozbek, Zuhtu;Kazanci, Burak;Guclu, Bulent
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.48-50
    • /
    • 2014
  • Brucellosis is caused by gram-negative, aerobic, non-motile, facultative, intracellular coccobacilli belonging to the genus Brucella. A 50-year-old man working as an employee was admitted to neurosurgery clinic with severe low back, radicular right leg pain and hypoesthesia in right L4-5 dermatomes for 2 months. Brucella tube agglutination (Wright) test was positive in serum sample of the patient with a titer of 1/640. Brucella melitensis was isolated from blood culture. X-ray and MRI of the lomber spine showed massive collapse of L4 vertebral body. Neural tissue was decompressed and then posterior L3-5 short segment transpedicular screw fixation and stabilization was performed. Brucella melitensis was isolated from microbiologic culture of pathologic specimen. Antibiotic therapy was given as doxycycline 200 mg/day and rifampicin 600 mg/day for 6 months. Brucellosis is a systemic zoonotic infection and still an important public health problem in many geographical parts of the world. Vertebral body collapse caused by brucellosis occurs very rarely but represents a neurosurgical emergency because of its potential for causing rapidly progressive spinal cord compression and permanent paralysis. Neurosurgeons, emergency department personnel as well as infectious disease specialists should always keep a high index of suspicion and include brucellosis in the differential diagnosis of vertebral body collapse.

The Usefulness of Arthroscopy in the Operative Treatment of Intra-Articular Calcaneal Fracture (관절 내 종골 골절의 수술적 치료에 있어 관절 내시경 사용의 유용성)

  • Chung, Kyung-Chil;Gwak, Heui-Chul;Kim, Chang-Wan;Kim, Jung-Han;Park, Dae-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.55-59
    • /
    • 2009
  • Purpose: We tried to evaluate the usefulness of the arthroscopy in the operative treatment of intra-articular calcaneal fracture. Materials and Methods: Between March 2005 and May 2008, 9 patients with intra-articular calcaneal fractures(Tongue type or Sanders type IIC) were treated with arthroscopically assisted percutaneous reduction and screw fixation. American orthopedic foot and ankle society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS), preoperative and postoperative Bohler's angle and the rate of complication were evaluated. Results: AOFAS score at postoperative 1 year was 88.2 (range, 71-92), and mean VAS score was 2.8 (range, 1-4). Bohler angle was improved from preoperative mean $16.2^{\circ}$ to postoperative mean $29.7^{\circ}$. There were no complications such as wound problem, infection or nerve injury. Conclusion: Subtalar arthroscopy provides precise view of posterior facet during the operation. Therefore, it can be a useful tool in treating intra-articular calcaneus fractures, especially tongue type and Sanders type IIC fractures.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.