• 제목/요약/키워드: Post-combustion $CO_2$ capture

검색결과 33건 처리시간 0.027초

후처리를 이용한 $CO_2$ 포집이 화력 발전설비 성능에 미치는 영향 해석 (Analysis of the Influence of Post-Combustion $CO_2$ Capture on the Performance of Fossil Power Plants)

  • 탁상현;김동섭;장영수;이대영;김민성
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.545-552
    • /
    • 2010
  • Research and development efforts to reduce $CO_2$ emission are in progress to cope with global warming. $CO_2$ emission from fossil fuel fired power plants is a major greenhouse gas source and the post-combustion $CO_2$ capture is considered as a short or medium term option to reduce $CO_2$ emissions. In this study, the application of the post-combustion $CO_2$ capture system, which is based on chemical absorption and stripping processes, to typical fossil fuel fired power plants was investigated. A coal fired plant and a natural gas fired combined cycle plant were selected. Performance of the MEA-based $CO_2$ capture system combined with power plants was analyzed and overall plant performance including the energy consumption of the $CO_2$ capture process was investigated.

가스하이드레이트 방법을 이용한 연소전 탈탄소화 기술 ($CO_2$ Capture in Pre-Combustion using Principles of Gas hydrate Formation)

  • 강경찬;이진우;이만식;김영석;이주동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.602-605
    • /
    • 2008
  • $CO_2$ 분리는 크게 연소전 탈탄소화(pre-combustion capture)와 연소후 포획(post-combustion capture)으로 나누어지는데, post-combustion capture는 연료가 연소하면 $N_2$$CO_2$가 남게 되고 흡수나, 흡착, 막분리 등을 이용해서 $CO_2$를 분리하는 것이고, Pre-combustion capture(연소전 회수)는 연소 전에 이산화탄소가 발생되지 않도록 하는 기술로써, 부분 산화나 개질 및 수성가스 변위반응 등이 포함되며 생성된 수소와 이산화탄소를 분리하여 수소를 생산하는 기술($CO_2/H_2$ 분리가 핵심)이다. 우리나라는 대부분 연소 후 포획 위주로 많은 연구가 진행되어 왔지만, 최근 고유가 시장이 형성되면서 석탄화력발전 및 복합가스발전(IGCC)에 필요한 연소전 탈탄소화($H_2/CO_2$ 가스로부터 $CO_2$ 회수) 연구에 산업적 관심이 급상승 되고 있다. 특히, Pre-combustion 과정에서는 높은 자체압력(약 2.5 - 5.0MPa)과 비교적 높은 농도의 $CO_2$(약 40%의)가 발생되기 때문에, 연소전 탈탄소화는 가스하이드레이트 형성/분해 원리가 가장 잘 적용될 수 있는 기술이라 할 수 있다. 본 연구에서는 비교적 저압 조건에서도 하이드레이트를 보다 쉽게 형성시키는 촉진제를 이용하여 $CO_2/H_2$ 혼합 가스 중 $CO_2$를 분리하는 실험을 수행하였다.

  • PDF

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

CO2 포집을 고려한 가스터빈 복합화력 발전 플랜트의 시스템 대안 평가를 위한 공학 설계 (Engineering design procedure for gas turbine combined cycle power plant with post-combustion CO2 capture)

  • 이수현;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.333-335
    • /
    • 2014
  • As the user demand for power plants becomes various, design objective becomes complicated. To review the system feasibility, system objective and evaluation criteria need to be newly defined. In this study, engineering design procedure of the multi-purpose power plant, such as barge-mounted combined cycle power plant with $CO_2$ capture, was shown as a previous work for the feasibility review of the system alternatives. For the system design, heat and mass balance for each system configuration was firstly performed. Using the thermal analysis results, conceptual design of system alternatives was carried out. And then, preliminary design of the major equipment was done. The engineering calculation results of this study would be used as the evaluation data for system feasibility review.

  • PDF

이산화탄소 배출을 최소화하는 용융탄산염 연료전지 하이브리드 시스템들의 성능 비교 (Performance Comparison of Molten Carbonate Fuel Cell Hybrid Systems Minimizing Carbon Dioxide Emissions)

  • 안지호;윤석영;김동섭
    • 한국수소및신에너지학회논문집
    • /
    • 제28권1호
    • /
    • pp.30-39
    • /
    • 2017
  • Interests in fuel cell based power generation systems are on the steady rise owing to various advantages such as high efficiency, ultra low emission, and potential to achieve a very high efficiency by a synergistic combination with conventional heat engines. In this study, the performance of a hybrid system which combined a molten carbonate fuel cell (MCFC) and an indirectly fired micro gas turbine adopting carbon dioxide capture technologies was predicted. Commercialized 2.5 MW class MCFC system was used as the based system so that the result of this study could reflect practicality. Three types of ambient pressure hybrid systems were devised: one adopting post-combustion capture and two adopting oxy-combustion capture. One of the oxy-combustion based system is configured as a semi-closed type, while the other is an open cycle type. The post-combustion based system exhibited higher net power output and efficiency than the oxy-combustion based systems. However, the semi-closed system using oxy-combustion has the advantage of capturing almost all carbon dioxide.

KEPCO-China Huaneng Post-combustion CO2 Capture Pilot Test and Cost Evaluation

  • Lee, Ji Hyun;Kwak, NoSang;Niu, Hongwei;Wang, Jinyi;Wang, Shiqing;Shang, Hang;Gao, Shiwang
    • Korean Chemical Engineering Research
    • /
    • 제58권1호
    • /
    • pp.150-162
    • /
    • 2020
  • The proprietary post-combustion CO2 solvent (KoSol) developed by the Korea Electric Power Research Institute (KEPRI) was applied at the Shanghai Shidongkou CO2 Capture Pilot Plant (China Huaneng CERI, capacity: 120,000 ton CO2/yr) of the China Huaneng Group (CHNG) for performance evaluation. The key results of the pilot test and data on the South Korean/Chinese electric power market were used to calculate the predicted cost of CO2 avoided upon deployment of CO2 capture technology in commercial-scale coal-fired power plants. Sensitivity analysis was performed for the key factors. It is estimated that, in the case of South Korea, the calculated cost of CO2 avoided for an 960 MW ultra-supercritical (USC) coal-fired power plant is approximately 35~44 USD/tCO2 (excluding CO2 transportation and storage costs). Conversely, applying the same technology to a 1,000 MW USC coal-fired power plant in Shanghai, China, results in a slightly lower cost (32~42 USD/tCO2). This study confirms the importance of international cooperation that takes into consideration the geographical locations and the performance of CO2 capture technology for the involved countries in the process of advancing the economic efficiency of large-scale CCS technology aimed to reduce greenhouse gases

기기적 증기 재압축 시스템을 적용한 연소 후 이산화탄소 포집공정 개선 연구 (Improvement of Post-combustion CO2 Capture Process using Mechanical Vapor Recompression)

  • 정영수;정재흠;한종훈
    • 한국가스학회지
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2016
  • 기후변화의 가장 큰 원인 중 하나로 지목되는 이산화탄소의 배출량을 절감하기 위해 제안된 Carbon Capture and Storage (CCS) 전체공정의 에너지 및 비용저감이 시급한 현 시점에서 효율적인 연계공정의 도출이 중요하며 본 연구에서는 연소 후 습식아민 공정을 이용한 포집공정과 압축공정의 간의 연계를 통해 에너지를 저감할 수 있는 방법을 제안한다. 이는 기기적 증기 재압축 시스템 을 적용하여 압축기에 사용되는 전기에너지를 열에너지의 형태로 변환함으로써 포집공정에 필요한 리보일러의 에너지 사용량을 감소시키는 방법이다. 본 공정개선안은 압축기에 필요한 추가적인 투자비용 및 전기에너지를 고려하더라도 고압의 이산화탄소를 생산함과 동시에 전체적인 에너지 사용량을 절감시키는 장점이 있다. 또한 본 연구에서는 실제 Test Bed의 운전 결과를 통한 모델을 활용함으로써 보다 신뢰성 있는 절감 효과를 제안하고자 한다.

순산소 연소기술

  • 김성철
    • 기계저널
    • /
    • 제50권9호
    • /
    • pp.34-38
    • /
    • 2010
  • $CO_2$ 포집기술은 크게 연소 후 포집(Post-Combustion Capture), 연소 중 포집기술인 순산소 연소(Oxy-Fuel Combustion) 및 연소 전 포집(Pre-Combustion)으로 구분되며, 이 글에서는 기존의 공기연소 대신에 산소만으로 연소하여 배가스 중의 수분을 응축 제거함으로써 $CO_2$를 포집하는 순산소 기술의 국내 외 개발현황 등을 소개한다.

  • PDF

습식아민 CO2 포집설비의 물 세정 단 설계에 따른 흡수제 손실 영향 평가 (The Effect of Designing Washing Column in Post Combustion CO2 Capture Plant on the Losses of Amine Solvent)

  • 한선구;고현신;김성규;최시묵
    • 플랜트 저널
    • /
    • 제13권2호
    • /
    • pp.34-38
    • /
    • 2017
  • 상업규모의 온실가스 저감 기술 중 대표적인 기술 중 하나인 연소 후 습식아민 $CO_2$포집 기술에서 기술의 개발에 중점을 두고 있는 부분이 운영비의 개선 부분이다. 습식아민 $CO_2$ 포집기술에서 사용되는 아민은 대체로 고가의 아민을 사용한다. 고가의 아민을 사용하기 때문에 설비 운영 중 발생하는 흡수제의 손실이 운영비에 영향을 미칠 수 있고 설비의 용량이 커질 수록 운영비는 더욱 커지게 된다. 본 연구에서는 150MW급 석탄화력발전소 배기가스에 아민흡수법 CCS기술을 적용 할 경우 흡수제의 손실이 설비 운영비에 미치는 영향과 물 세정 타워의 설계가 흡수제 손실 절감에 어떠한 영향을 미치는지 살펴 보았다.

  • PDF

연소 후 이산화탄소 포집용 흡수제의 비활성화 원인 규명 (Deactivation causes of dry sorbents for post-combustion CO2 capture)

  • 조민선;채호진;이수출;조성빈;김태영;이철호;백점인;김재창
    • Korean Chemical Engineering Research
    • /
    • 제57권2호
    • /
    • pp.253-258
    • /
    • 2019
  • 연소 후 이산화탄소 포집용 고속 유동층 공정에서 사용되는 흡수제를 대량생산할 때, 흡수제 강도를 위해 여러 가지 물질을 사용한다. 본 연구에서는 흡수제 설계시 사용하는 물질 중 하나인 Micro-cell C (MCC)를 사용하여 $K_2CO_3$ 기반 건식 흡수제(KMC)를 제조하였고, 흡수 및 재생 특성을 평가하였다. 흡수반응은 $60^{\circ}C$에서 실험하였고, 재생반응은 $200^{\circ}C$에서 실험하였다. KMC 흡수제의 연속실험 결과, 1 cycle임에도 불구하고 이론흡수능(95.4 mg $CO_2/g$ sorbent)의 약 22%인 21.6 mg $CO_2/g$ sorbent의 낮은 흡수능을 나타내었고, 5 cycle에서는 13.7 mg $CO_2/g$ sorbent의 낮은 흡수능을 나타내었다. XRD 및 TG 분석결과, MCC에 함유된 Ca계 성분으로 인해 제조 및 흡수 과정에서 부반응 물질인 $K_2Ca(CO_3)_2$ 구조가 생성됨에 따라 흡수제가 비활성화된 것을 확인하였다. 또한 흡수제 비활성화 문제를 해결하기 위해, MCC를 $850^{\circ}C$에서 먼저 소성하는 과정을 추가하여 흡수제(KM8)를 제조하였다. KM8 흡수제는 1 cycle에서 95.2 mg $CO_2/g$ sorbent의 높은 흡수능을 나타낼 뿐만 아니라 5 cycle 동안 우수한 재생성을 나타내었다. 따라서 소성단계를 추가함으로써 부반응 원인물질 제거방법을 통해 흡수제의 비활성화를 해결할 수 있음을 확인하였다.