• Title/Summary/Keyword: Post-Hoc

Search Result 1,272, Processing Time 0.026 seconds

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

A Study on Actual Usage of Information Systems: Focusing on System Quality of Mobile Service (정보시스템의 실제 이용에 대한 연구: 모바일 서비스 시스템 품질을 중심으로)

  • Cho, Woo-Chul;Kim, Kimin;Yang, Sung-Byung
    • Asia pacific journal of information systems
    • /
    • v.24 no.4
    • /
    • pp.611-635
    • /
    • 2014
  • Information systems (IS) have become ubiquitous and changed every aspect of how people live their lives. While some IS have been successfully adopted and widely used, others have failed to be adopted and crowded out in spite of remarkable progress in technologies. Both the technology acceptance model (TAM) and the IS Success Model (ISSM), among many others, have contributed to explain the reasons of success as well as failure in IS adoption and usage. While the TAM suggests that intention to use and perceived usefulness lead to actual IS usage, the ISSM indicates that information quality, system quality, and service quality affect IS usage and user satisfaction. Upon literature review, however, we found a significant void in theoretical development and its applications that employ either of the two models, and we raise research questions. First of all, in spite of the causal relationship between intention to use and actual usage, in most previous studies, only intention to use was employed as a dependent variable without overt explaining its relationship with actual usage. Moreover, even in a few studies that employed actual IS usage as a dependent variable, the degree of actual usage was measured based on users' perceptual responses to survey questionnaires. However, the measurement of actual usage based on survey responses might not be 'actual' usage in a strict sense that responders' perception may be distorted due to their selective perceptions or stereotypes. By the same token, the degree of system quality that IS users perceive might not be 'real' quality as well. This study seeks to fill this void by measuring the variables of actual usage and system quality using 'fact' data such as system logs and specifications of users' information and communications technology (ICT) devices. More specifically, we propose an integrated research model that bring together the TAM and the ISSM. The integrated model is composed of both the variables that are to be measured using fact as well as survey data. By employing the integrated model, we expect to reveal the difference between real and perceived degree of system quality, and to investigate the relationship between the perception-based measure of intention to use and the fact-based measure of actual usage. Furthermore, we also aim to add empirical findings on the general research question: what factors influence actual IS usage and how? In order to address the research question and to examine the research model, we selected a mobile campus application (MCA). We collected both fact data and survey data. For fact data, we retrieved them from the system logs such information as menu usage counts, user's device performance, display size, and operating system revision version number. At the same time, we conducted a survey among university students who use an MCA, and collected 180 valid responses. A partial least square (PLS) method was employed to validate our research model. Among nine hypotheses developed, we found five were supported while four were not. In detail, the relationships between (1) perceived system quality and perceived usefulness, (2) perceived system quality and perceived intention to use, (3) perceived usefulness and perceived intention to use, (4) quality of device platform and actual IS usage, and (5) perceived intention to use and actual IS usage were found to be significant. In comparison, the relationships between (1) quality of device platform and perceived system quality, (2) quality of device platform and perceived usefulness, (3) quality of device platform and perceived intention to use, and (4) perceived system quality and actual IS usage were not significant. The results of the study reveal notable differences from those of previous studies. First, although perceived intention to use shows a positive effect on actual IS usage, its explanatory power is very weak ($R^2$=0.064). Second, fact-based system quality (quality of user's device platform) shows a direct impact on actual IS usage without the mediating role of intention to use. Lastly, the relationships between perceived system quality (perception-based system quality) and other constructs show completely different results from those between quality of device platform (fact-based system quality) and other constructs. In the post-hoc analysis, IS users' past behavior was additionally included in the research model to further investigate the cause of such a low explanatory power of actual IS usage. The results show that past IS usage has a strong positive effect on current IS usage while intention to use does not have, implying that IS usage has already become a habitual behavior. This study provides the following several implications. First, we verify that fact-based data (i.e., system logs of real usage records) are more likely to reflect IS users' actual usage than perception-based data. In addition, by identifying the direct impact of quality of device platform on actual IS usage (without any mediating roles of attitude or intention), this study triggers further research on other potential factors that may directly influence actual IS usage. Furthermore, the results of the study provide practical strategic implications that organizations equipped with high-quality systems may directly expect high level of system usage.

Effects of Transaction Characteristics on Distributive Justice and Purchase Intention in the Social Commerce (소셜커머스에서 거래의 특성이 분배적 정의와 거래 의도에 미치는 영향)

  • Bang, Youngsok;Lee, Dong-Joo
    • Asia pacific journal of information systems
    • /
    • v.23 no.2
    • /
    • pp.1-20
    • /
    • 2013
  • Social commerce has been gaining explosive popularity, with typical examples of the model such as Groupon and Level Up. Both local business owners and consumers can benefit from this new e-commerce model. Local business owners have a chance to access potential customers and promote their products in a way that could not have otherwise been easily possible, and consumers can enjoy discounted offerings. However, questions have been increasingly raised about the value and future of the social commerce model. A recent survey shows that about a third of 324 business owners who ran a daily-deal promotion in Groupon went behind. Furthermore, more than half of the surveyed merchants did not express enthusiasm about running the promotion again. The same goes for the case in Korea, where more than half of the surveyed clients reported no significant change or even decrease in profits compared to before the use of social commerce model. Why do local business owners fail to exploit the benefits from the promotions and advertisements through the social commerce model and to make profits? Without answering this question, the model would fall under suspicion and even its sustainability might be challenged. This study aims to look into problems in the current social commerce transactions and provide implications for the social commerce model, so that the model would get a foothold for next growth. Drawing on justice theory, this study develops theoretical arguments for the effects of transaction characteristics on consumers' distributive justice and purchase intention in the social commerce. Specifically, this study focuses on two characteristics of social commerce transactions-the discount rate and the purchase rate of products-and investigates their effects on consumers' perception of distributive justice for discounted transactions in the social commerce and their perception of distributive justice for regular-priced transactions. This study also examines the relationship between distributive justice and purchase intention. We conducted an online experiment and gathered data from 115 participants to test the hypotheses. Each participant was randomly assigned to one of nine manipulated scenarios of social commerce transactions, which were generated based on the combination of three levels of purchase rate (high, medium, and low) and three levels of discount rate (high, medium, and low). We conducted MANOVA and post-hoc ANOVA to test hypotheses about the relationships between the transaction characteristics (purchase rate and discount rate) and distributive justice for each of the discounted transaction and the regular-priced transaction. We also employed a PLS analysis to test relations between distributive justice and purchase intentions. Analysis results show that a higher discount rate increases distributive justice for the discounted transaction but decreases distributive justice for the regular-priced transaction. This, coupled with the result that distributive justice for each type of transaction has a positive effect on the corresponding purchase intention, implies that a large discount in the social commerce may be helpful for attracting consumers, but harmful to the business after the promotion. However, further examination reveals curvilinear effects of the discount rate on both types of distributive justice. Specifically, we find distributive justice for the discounted transaction increases concavely as the discount rate increases while distributive justice for the regular-priced transaction decreases concavely with the dscount rate. This implies that there exists an appropriate discount rate which could promote the discounted transaction while not hurting future business of regular-priced transactions. Next, the purchase rate is found to be a critical factor that facilitates the regular-priced transaction. It has a convexly positive influence on distributive justice for the transaction. Therefore, an increase of the rate beyond some threshold would lead to a substantial level of distributive justice for the regular-priced transaction, threrby boosting future transactions. This implies that social commerce firms and sellers should employ various non-price stimuli to promote the purchase rate. Finally, we find no significant relationship between the purchase rate and distributive justice for the discounted transaction. Based on the above results, we provide several implications with future research directions.

  • PDF

Physical properties of novel composite using Portland cement for retro-filling material (치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰)

  • Lee, Sang-Jin;Cho, Ok-In;Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.445-452
    • /
    • 2010
  • Objectives: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. Materials and Methods: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. Results: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). Conclusions: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.

A Study on Recognition and Practice of Teakyo by Pregnant Women (임부의 태교인식과 태교실천에 관한 조사연구)

  • Shin, Yong-Bun;Koh, Hyo-Jung
    • Women's Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.142-152
    • /
    • 2000
  • This study is a descriptive study to offer an actual basic data as Nursing intervention strategy of nurses before delivery in order that pregnant women in Korea may effectively practice Taekyo by examining the relation after apprehending level of recognition and practice of our pregnant women about Taekyo. This study collected questionnaires from 801 pregnant women who visited general hospitals in 10 areas(Seoul, Daejon, chunan, Daegu, Kummi, $Ky{\check{o}}ngju$, $P{\ddot{o}}hang$, Busan, $J{\ddot{o}}nju$, and $Y{\ddot{o}}nkwang$) for prenatal care through an outpatient obstetrics and gynecology from July 15 to August 30, 1999. This study used the tool of lee, Ki Young(1993) revised an complemented by investigator to measure recognition of Taekyo and the tool of Jang, Shun Buk and Park, Young Ju(1996) revised and complemented by investigator to measure practice of Taekyo. The Cronbach's alpha value of each tool was .88 in recognition of Taekyo, while the value was .90 in practice of Taekyo. For data analysis, this study used the descriptive and statistical analysis, Pearson correlation, t-test, ANOVA, Tukey's post hoc contrast, and Stepwise multiple regression in accordance with the purpose of this study with using SPSS Win 7.5 program. The results were as follows ; 1. The practice of Taekyo was low in comparison with recognition of Teakyo by showing average 4.28 points and standard deviation 0.48 at level of recognition of pregnant women about Taekyo on the basis of 5 points and showing to show average 2.81 points and standard deviation 0.36 at practice level on the basis of 4 points. 2. They showed the higher level of recognition on Taekyo at high educational background of pregnant woman(F=3.735, p=.005), Roman catholicism (F=4.570, p=.002), satisfied married life(F=5.448, p=.004), high monthly income(F=6.096, p=.000) and cases of hoping pregnancy(F=2.525, p=.012). 3. They showed the higher level of practice on Taekyo at high educational background of pregnant woman(F=2.883, P=.022), Roman catholicism(F=3.616, p=.032), satisfied married life(F=19.924, p=.000), good health condition(F=2.386, p=.017), cases of hoping pregnancy(F=0.677, p=.000), cases of planning pregnancy with husband(F=3.024, p=.001), cases of regular prenatal care before delivery(F=0.241, p=.005), cases of maternal breast feeding (F=9.132, p=.000), and the number of less children(F=2.763, p=.041). 4. In result of examining correlation between recognition and practice of Taekyo, they showed high level of practice on Taekyo under high level of recognition of pregnant women on Taekyo by showing the statistically significant correlation. 5. In result of examining the related factors that affect recognition and practice of Taekyo y the object, practice of Taekyo had 16.8 percents of explanatory range, purpose of practicing Taekyo 8.5 percents of explanatory range, and monthly income 1.9 percent of explanatory range as variables of affecting recognition of Taekyo. The total explanatory range was 27.2 percents, Recognition of Taekyo had 16.1 percents of explanatory ragne, time of starting Taekyo 3.2 percents, health condition 2.2 percents of explanatory range, condition of hoping pregnancy 1.1 percent of explanatory range, satisfaction of married life 0.8 percent of explanatory range, and religion 0.6 percent of explanatory range as variables of affecting practice of Taekyo. The total explanatory range was 24.0 percents.

  • PDF

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Comparison of the effect of removing artificial dental plaque depending on various interdental cleaning products on the interdental surface of zirconia crowns (치간 세정 용품에 따른 지르코니아 크라운 인접면의 인공 치면 세균막 제거 효과)

  • Kim, Hyun-Wook;Song, Ha-Kyung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose. The purpose of this study is to compare five interdental cleansing products' effectiveness on removing artificial dental plaque on the interdental space of zirconia crowns. Materials and methods. A model with abutments on the right mandibular second premolar and first molar were prepared. 10 zirconia crowns for each abutment were fabricated. After applying artificial dental plaque between the zirconia crowns, a single clinician attempted to remove the plaque with five products: interdental toothbrush, end-tuft toothbrush, dental floss, Easypick, Water pik. They were conducted 10 times per group. The aspect and area of removed surfaces were analyzed using images taken with a digital camera. One factor analysis of variance was performed as a statistical analysis, and a post-hoc test was performed using the Scheffé method (P < .05). Results. There were differences in the area and the pattern according to the characteristics of the products. The largest area, including the marginal portion, was removed in the dental floss group. Interdental toothbrush group was the most effective in removing the dental plaque at the marginal portion. Easypick was less effective than the interdental toothbrush. The end-tuft toothbrush showed better results than other products in cleansing mesiobuccal and distobuccal area, but could not cleanse the area directly below the contact point. In Water pik group, artificial dental plaque was scarcely removed. The removal rate of artificial dental plaque was in the order of floss (69.47%), end-tuft toothbrush (49.36%), interdental toothbrush (44.20%), Easy pick (13.04%), and Water pik (0.59%). Conclusion. Dental floss showed the highest removal rate in the interdental space restored with zirconia crowns, while interdental toothbrush was the most effective in removing the dental plaque at the marginal portion.

Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment (법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교)

  • Lee, Ye-Rim;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.72-80
    • /
    • 2019
  • Purpose: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. Materials and Methods: G-FIX and LightFix were used as tooth splinting materials. Twenty bovine mandibular incisors were used for the preparation of the specimens. The exposed enamel surface was separated into four parts. Each tooth was treated with 37% phosphoric acid, 37% phosphoric acid + adhesive resin, 37% phosphoric acid + G-premio bond, and G-premio bond for each fraction. Shear bond strength was measured using a universal testing machine. After measuring the shear bond strength, the fractured surface of the specimen was magnified with a microscope to observe the fracture pattern. Two-way ANOVA was used to verify the interaction between the material and the surface treatment method. One-way ANOVA was used for comparison between the surface treatment methods of each material and post-hoc test was conducted with Scheffe's test. An independent t-test was conducted to compare shear bond strengths between materials in each surface treatment method. All statistics were conducted at 95% significance level. Results: G-FIX, a tooth splinting resin, showed similar shear bonding strength when additional adhesive resins were used when material was applied after only acid etching, and LightFix showed the highest shear bonding strength when additional adhesive resins were used after the acid etching. In addition, both G-FIX and LightFix showed the lowest shear bond strength when only self-etching adhesive was applied without additional acid etching. Verification of interactions observed interconnection between resins and surface treatment methods. Most of the mixed failure was observed in all counties. Conclusion: When using G-FIX and LightFix, which are tooth-splinting materials, it is considered that sufficient adhesion will be achieved even after applying only acid etching as instructed by the manufacturer.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.