• Title/Summary/Keyword: Post structures

Search Result 935, Processing Time 0.023 seconds

Effects of Post-Annealing on Properties of HfO2 Films Grown by ALD (ALD법으로 성장한 HfO2 박막의 열처리에 따른 특성변화)

  • Lee, J.W.;Ham, M.H.;Maeng, W.J.;Kim, H.;Myoung, J.M.
    • Korean Journal of Materials Research
    • /
    • v.17 no.2
    • /
    • pp.96-99
    • /
    • 2007
  • The effects of post-annealing of high-k $HfO_2$ thin films grown by atomic layer deposition method were investigated by the annealing treatments of $400-600^{\circ}C$. $Pt/HfO_2/p-Si\;MOS$ capacitor structures were fabricated, and then the capacitance-voltage and current-voltage characteristics were measured to analyze the electrical characteristics of dielectric layers. The X-ray diffraction analyses revealed that the $500^{\circ}C-annealed\;HfO_2$ film remained to be amorphous, and the $600^{\circ}C-annealed\;HfO_2$ film was crystallized. The annealing treatment at $500^{\circ}C$ resulted in the highest capacitance and the lowest leakage current due to the reduction of defects in the $HfO_2$ films and non-crystallization. Our results suggest that post-annealing treatments are a critical factor in improving the characteristics of gate dielectric layer.

Assessment and quantification of hurricane induced damage to houses

  • Chiu, Gregory L.F.;Wadia-Fascetti, Sara Jean
    • Wind and Structures
    • /
    • v.2 no.3
    • /
    • pp.133-150
    • /
    • 1999
  • Significant costs to the public and private sectors due to recent extreme wind events have motivated the need for systematic post-hurricane damage data collection and analysis. Current post disaster data are collected by many different interested groups such as government agencies, voluntary disaster relief agencies, representatives of media companies, academicians and companies in the private sector. Each group has an interest in a particular type of data. However, members of each group collect data using different techniques. This disparity in data is not conducive to quantifying damage data and, therefore, inhibits the statistical and spatial description of damage and comparisons of damage among different extreme wind events. The data collection does not allow comparisons of data or results of analyses within a group and also prohibits comparison of damage data and information among different groups. Typically, analyses of data from a given event lead to different conclusion depending upon the definition of damage used by individual investigators and the type of data collected making it difficult for members of groups to compare the results of their analyses with a common language and basis. A formal method of data collection and analysis-within any single group-would allow comparisons to be made among different individuals, hazardous events and eventually among different groups, thus facilitating the management and reduction of damage due to future disaster. This research introduces a definition of damage to single family dwellings, and a common method of data collection and analysis suited for groups interested in regional characterization of damage. The current state-of-data is presented and a method for data collection is recommended based on these existing data collection methods. A fixed-scale damage index is proposed to consider the damage to a dwelling's feature. Finally, the damage index is applied to three dwellings damaged by Hurricane Iniki (1992). The damage index reflects the reduced functionality of a structure as a single family detached dwelling and provides a means to evaluate regional damage due to a single event or to compare damage due to events of different severity. Evaluation of the damage index and the data available support recommendation for future data collection efforts.

A STUDY ON THE PRE-AND POST-IRRADIATION EFFECT OF BLOOD VESSELS IN THE EXPERIMENTALLY INDUCED TONGUE CANCER (실험적 설암에서 방사선 조사전후의 혈관분포에 관한 연구)

  • Kim Young-Tae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.41-49
    • /
    • 1990
  • The author observed the changes of vasculature of pre-and post-irradiation on DMBA induced rat tongue cancer. The study was performed by using vascular corrosion resin casting, and scanning electron microscopy. The results were as follows. 1. The capillaries runned parallely and formed bundles and, sometimes, plexus. The endothelial cells were arranged regularly and small pores were observed. 2. In irradiated normal tongue the capillaries were curved slightly and formed plexus on initial day of post-irradiation. On third day the capillaries and capillary pores were dilated and the endothelial cell arrangement was irregular. The effects of irradiation were gradually increased from initial to the 3rd day, though it was decreased after 7th day. 3. The vasculature of DMBA induced tongue cancer group were very irregular, and large avascular lesions were formed according to the cancer necrosis or tumor cell nest and the vasculature was narrowed and paralleled around the avascular lesion by compression of cancer cell nest. The vascular wall was roughened and dilated, forming club shaped or varix. 4. The vessels were curved and formed reticular network in irradiated DMBA induced tongue carinoma group. The free end of newly formed capillaries had regular width, and also irregular club shaped or aneurysmal dilatation were observed. The vascular structures were destroyed and vessels were fused in tumor necrosis lesion. The radiation effects were marked on the first and third day of irradiation and the effects were decreased after seventh day and showed capillary regeneration.

  • PDF

An Assumed Strain Beam Element for Spatial Post-Buckling Analysis of Non-symmetric and Shear Flexible Thin-Walled Beams (박벽보의 3차원 후좌굴 해석을 위한 Locking-Free 보요소)

  • Lee, Kyoung-Chan;Kim, Moon-Young;Park, Jung-Il;Chang, Sung-Pil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.719-730
    • /
    • 2007
  • This study presents a thin-walled space frame element based on the classical Timoshenko beam theory. The element is derived according to the assumed strain field in order to resolve the shear-locking phenomenon. The shape function is developed in accordance with the strain field which is assumed to be constant at a 2-noded straight frame element. In this study, the geometrically nonlinear analysis applies the Corotational procedure in order to evaluate unbalanced loads. The bowing effect is also considered faithfully. Two numerical examples are given; monosymmetric curved and nonsymmetric straight cantilever. When these example structures behave lateral-torsional bucking, the critical loads are obtained by this study and ABAQUS shell elements. Also, the post-buckling behavior is examined. The results give good agreement between this study and ABAQUS shell.

Change in Electrical Properties of Al2O3/GaN MIS Structures according to the Thickness of Al2O3 Thin Film and Annealing Temperature (산화알루미늄 박막의 두께 및 열처리 온도에 따른 Al2O3/GaN MIS 구조의 전기적 특성 변화)

  • Kwak, No-Won;Lee, Woo-Seok;Kim, Ka-Lam;Kim, Hyun-Jun;Kim, Kwang-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.470-475
    • /
    • 2009
  • We deposited $Al_2O_3$ thin films on GaN by remote plasma atomic layer deposition (RPALD) technique, trimethylaluminum(TMA) and oxygen were used as precursors, at fixed process condition, the number of cycle were changed. Growth rate per cycle was $1.2\;{\AA}$/cycle. and Growth rate was in proportion to a number of cycle, the GaN MIS capacitors that $Al_2O_3$ thin film were deposited above 12 nm, have excellent electrical properties, a low electrical leakage current density(${\sim}10^{-10}\;A/cm^2$ at 1.5 MV), but below 12 nm, we can see the degradation of the leakage current density. After post deposition annealing, Dielectric constant was estimated by 1 MHz high-frequency C-V method, it was varied with the anealing temperature from 6.9 at no post anealed to 7.6 at $800^{\circ}C$, and we can see a improvement of the leakage current density and breakdown voltage by post deposition anealing below $700^{\circ}C$, but, after anealed at $800^{\circ}C$, we can see the degradation of the leakage current density and breakdown voltage.

Quality parameters of chicken breast meat affected by carcass scalding conditions

  • Silva-Buzanello, Rosana Aparecida da;Schuch, Alexia Francielli;Gasparin, Andre Wilhan;Torquato, Alex Sanches;Scremin, Fernando Reinoldo;Canan, Cristiane;Soares, Adriana Lourenco
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.8
    • /
    • pp.1186-1194
    • /
    • 2019
  • Objective: The influence of broiler carcass scalding conditions on chicken breast meat quality parameters was investigated. Methods: Two hundred and seventy Cobb broiler chickens from 42 to 48 days old were slaughtered according to the standard industry practice and scalded in five temperature/time combinations-$T_1$, $54^{\circ}C/210s$; $T_2$, $55^{\circ}C/180s$; $T_3$, $56^{\circ}C/150s$; $T_4$, $57^{\circ}C/120s$; $T_5$, $58^{\circ}C/90s$. Results: Scalding temperature increase resulted in higher values of external and ventral lightness and in protein functionality reduction-determined by emulsification capacity and protein denaturation-in chicken breast fillets 24 h post-mortem. Protein secondary structures had conformational changes, with a decrease of the ${\alpha}$-helix and an increase of the ${\beta}$-sheet and ${\beta}$-turn proportions, mainly in $T_1$ and $T_5$ samples, determined by Fourier-transform infrared spectroscopy in an attenuated reflectance mode analysis. The chemical composition, pH, water holding capacity and Warner-Bratzler shear force did not differ among the treatments. In the fatty acid profile, the 18:1n-9 was lower in $T_5$, which suggested that the high scalding-temperature could have caused the lipid oxidation. The values of the polyunsaturated fatty acids (PUFA), such as 22:2, 20:4n-6, and 22:6n-3, were highest in the $T_5$, thus being related to the phospholipid cellular membrane collapse in this experimental condition and subsequent release of these PUFA. Conclusion: Intermediate scalding-parameters avoided the negative changes in the chicken meat quality.

Analytical post-heating behavior of concrete-filled steel tubular columns containing tire rubber

  • Karimi, Amirhossein;Nematzadeh, Mahdi;Mohammad-Ebrahimzadeh-Sepasgozar, Saleh
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.467-482
    • /
    • 2020
  • This research focused on analyzing the post-fire behavior of high-performance concrete-filled steel tube (CFST) columns, with the concrete containing tire rubber and steel fibers, under axial compressive loading. The finite element (FE) modeling of such heated columns containing recycled aggregate is a branch of this field which has not received the proper attention of researchers. Better understanding the post-fire behavior of these columns by measuring their residual strength and deformation is critical for achieving the minimum repair level required for structures damaged in the fire. Therefore, to develop this model, 19 groups of confined and unconfined specimens with the variables including the volume ratio of steel fibers, tire rubber content, diameter-to-thickness (D/t) ratio of the steel tube, and exposure temperature were considered. The ABAQUS software was employed to model the tested specimens so that the accurate behavior of the FE-modeled specimens could be examined under test conditions. To achieve desirable results for the modeling of the specimens, in addition to the novel procedure described in this research, the modified versions of models presented by previous researchers were also utilized. After the completion of modeling, the load-axial strain and load-lateral strain relationships, ultimate strength, and failure mode of the modeled CFST specimens were evaluated against the test data, through which the satisfactory accuracy of this modeling procedure was established. Afterward, using a parametric study, the effect of factors such as the concrete core strength at different temperatures and the D/t ratio on the behavior of the CFST columns was explored. Finally, the compressive strength values obtained from the FE model were compared with the corresponding values predicted by various codes, the results of which indicated that most codes were conservative in terms of these predictions.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

The bearing capacity of monolithic composite beams with laminated slab throughout fire process

  • Lyu, Junli;Zhou, Shengnan;Chen, Qichao;Wang, Yong
    • Steel and Composite Structures
    • /
    • v.38 no.1
    • /
    • pp.87-102
    • /
    • 2021
  • To investigate the failure form, bending stiffness, and residual bearing capacity of monolithic composite beams with laminated slab throughout the fire process, fire tests of four monolithic composite beams with laminated slab were performed under constant load and temperature increase. Different factors such as post-pouring layer thickness, lap length of the prefabricated bottom slab, and stud spacing were considered in the fire test. The test results demonstrate that, under the same fire time and external load, the post-pouring layer thickness and stud spacing are important parameters that affect the fire resistance of monolithic composite beams with laminated slab. Similarly, the post-pouring layer thickness and stud spacing are the predominant factors affecting the bending stiffness of monolithic composite beams with laminated slab after fire exposure. The failure forms of monolithic composite beams with laminated slab after the fire are approximately the same as those at room temperature. In both cases, the beams underwent bending failure. However, after exposure to the high-temperature fire, cracks appeared earlier in the monolithic composite beams with laminated slab, and both the residual bearing capacity and bending stiffness were reduced by varying degrees. In this test, the bending bearing capacity and ductility of monolithic composite beams with laminated slab after fire exposure were reduced by 23.3% and 55.4%, respectively, compared with those tested at room temperature. Calculation methods for the residual bearing capacity and bending stiffness of monolithic composite beams with laminated slab in and after the fire are proposed, which demonstrated good accuracy.

Development of an Objective Structured Clinical Examination Checklist and a Post-Education Questionnaire for Musculoskeletal Ultrasound Training Focusing on Volar Wrist and Carpal Tunnel Syndrome

  • Cho, Eunbyul;Han, Young-Min;Kang, Yeonseok;Kim, Jae-Hyo;Shin, Min-Seop;Oh, Myungjin;Jung, Hyun-Jong;Jeon, Hyesoo;Cho, Nam Geun;Leem, Jungtae
    • Journal of Acupuncture Research
    • /
    • v.39 no.2
    • /
    • pp.105-114
    • /
    • 2022
  • Background: The objective structured clinical examination (OSCE) is used in the colleges of Korean Medicine, but few studies have validated the OSCE evaluation criteria or post-education questionnaires. Diagnostic ultrasound is used in Korean medicine treatment including acupuncture, acupotomy, and pharmacopuncture to increase the safety and efficacy of treatment. We aimed to develop and validate a OSCE checklist and questionnaire for diagnostic musculoskeletal ultrasound training. Methods: A OSCE checklist and rubric for diagnostic ultrasound training, and questionnaire was developed using literature research. Eight expert panelists verified each draft item in a single-round survey. Items with a content validity ratio (CVR) < 0.75 were excluded or modified to reflect the experts' opinions. Results: The OSCE checklist and rubric for diagnostic ultrasound training focusing on volar wrist and carpal tunnel syndrome included: 15 items revised according to CVR and expert opinions, the pre-examination procedure, structures to be identified by ultrasound, scans with 2 diagnostic criteria for carpal tunnel syndrome, an explanation of the exam results, and the post exam procedure. The questionnaire consisted of 15 items, including the overall evaluation of training, the effect of the OSCE, and the perception of the ultrasound. All 6 self-evaluation items were not revised, as they had a CVR of ≥ 0.75. Conclusion: An ultrasound OSCE for scanning the volar wrist and diagnosing carpal tunnel syndrome was developed using 15 validated tasks, 15 survey questions about ultrasound training, and 6 questions for self-evaluation. These results may be used in the future for education in diagnostic ultrasound.