• Title/Summary/Keyword: Post plasma

Search Result 445, Processing Time 0.022 seconds

Influence of CrO3 Sealing Treatment on Properties of Plasma Sprayed Al2O3 Coating (플라즈마 용사 Al2O3 코팅의 특성에 미치는 CrO3 봉공처리의 영향)

  • Cho, Kyeong-Sik;Lee, Hyun-Kwuon;Kwon, Jeong-Cheol
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.2
    • /
    • pp.160-167
    • /
    • 2011
  • Plasma sprayed ceramic coatings inherently contain pores and usually also cracks. Post-treatment of the plasma sprayed coatings is a way to close the connected pores and cracks. In this study, post-sealing treatment in plasma sprayed $Al_2O_3$ coatings was employed to overcome the reduction of coating properties. $Al_2O_3$ plasma thermal spray coating was made on aluminum alloys plate, $CrO_3$ post coating and heat treatment at $550^{\circ}C$ was carried out in order for final $Cr_2O_3$ to be saturated through phase transformation. Chromia sealing began at the fine defect in coated microstructure, while larger pores were permeated later. The increase in concentration and treatment frequency of sealing solution resulted in the decrease of porosity of coating layer, while cracks occurred partially after the third treatment. After twice treatment of 10M $CrO_3$ solution, microhardness and breakdown voltage of $Al_2O_3$ coatings were found to increase by ${\fallingdotseq}$ 50% and ${\fallingdotseq}$ 390% respectively than without post-treatment.

Effects of Nitrogen Contents on the Nitriding Characteristics of the Micro-Pulse Plasma and Post Oxidation Treated SCM440 Steel (SCM440강의 마이크로 펄스 플라즈마 질화 및 후산화처리시 질소농도에 따른 특성변화)

  • Lee, S.K.;Chung, I.S.;Lee, J.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.117-128
    • /
    • 1999
  • This study was carried out to investigate the surface characteristics of SCM440 steel nitrided with various nitrogen contents for 7 hours at $520^{\circ}C$ by using micro-pulse plasma nitriding apparatus of hot wall type. The effects of oxidation treatment was also investigated on plasma nitrided in 30% nitrogen and post oxidized SCM440 steel at $500^{\circ}C$ in $H_2O$ atmosphere. The ${\gamma}^{\prime}-Fe_4N$ and ${\varepsilon}-Fe_{2-3}N$ phases were detected in compound layer of the nitrided steel. As the content of nitrogen in plasma gas increased with 30, 50, 70% on the micro-pulse plasma nitriding for SCM440 steel, the thickness of compound, diffusion layer and the surface hardness were increased. From the wear test results, the best wear resistance was appeared in the condition of ductile ${\gamma}^{\prime}-Fe_4N$ phase formed specimen at 30% nitrogen, whereas that of the treated with 50% and 70% nitrogen decreased owing to the exfoliation of brittle ${\varepsilon}-Fe_{2-3}N$ phase in the compound layer. On the nitrided and subsequently oxidized SCM440 steel, the surface layer consisted of $Fe_3O_4$, ${\gamma}^{\prime}-Fe_4N$, and ${\varepsilon}-Fe_{2-3}N$ phases. In these treatments, the dissolution of nitrides affect hardness and hardening depth in compound and diffusion layers. For the nitrided in 30% nitrogen and post oxidized specimen at $500^{\circ}C$ for 1 hour, the wear resistance was lower than that of the only nitrided one in 30% nitrogen but higher than those of the nitrided ones in 50 and 70% nitrogen.

  • PDF

A Study on the Corrosion Resistance of Free Cutting Steels after Oxy-Nitriding (진공산질화기술에 의한 쾌삭강의 내부식성 향상기술)

  • Moon, Kyoung Il;Kim, Sang Gweon;Kim, Sung Wan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.19 no.2
    • /
    • pp.90-95
    • /
    • 2006
  • Nitriding or carburizing of carbon steels results in good mechanical properties such as high surface hardness and wear resistance but it has no affection on the corrosion resistance. Corrosion properties of nitriding and carburizing steels could be deteriorated. So, recently, there have been great demand for oxi-nitriding to enhance both mechanical properties and corrosion resistance. In this study, the corrosion resistance of carbon steel, S35C, and free cutting steel, SUM222, are prepared by vacuum nitriding and vacuum post-oxidation were compared with those treated by nitriding. After vacuum post-oxidation, $5{\mu}m$ oxide layer was formed on the nitride layer with $20{\sim}30{\mu}m$ depth. Potentio-dynamic polarization curve in corrosion test showed that the corrosion potential after post oxidation was increased from 200 mV to 800 mV in S35C and from 600 mV to 1200 mV in SUM222. SEM analyses showed that pores was increased and surface roughness became rougher with post oxidation. However, the formation of $Fe_3O_4$ resulted in the enhanced corrosion resistance of steels.

Erythropoietic Activity in Plasma of Chronic Post-hemorrhagic Anemic Men (만성 실혈성 빈혈자 혈장의 적혈구조혈 작용)

  • Kim, Wan-Tai;Chung, Kwan-Ogg;Kim, Yoon-Sun;Cho, Yong-Moon;Chung, Won-Keun;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.4 no.1
    • /
    • pp.55-57
    • /
    • 1970
  • Erythropoietic activity in anemic Plasma of chronic posthemorrhagic anemic men was studied in rats after subcutaneous injection of anemic plasma. Anemic plasma was obtained from blood donors who sold their blood once or twice a week for one or two years to blood bank. Hemoglobin concentrations of 8 blood donors ranged between 4.6 and 8.4 gm/100 ml. Pooled plasma was treated by acidification-boiling method and adjusted to pH 7.5 by adding 0.1 N NaOH. 7ml/kg and 15ml/kg of anemic plasma filtrate was injected to 2 groups of rats respectively for 7 and 8 days. Hemoglobin concentrations, red blood cell counts and reticulocyte counts were observed before and after injection of anemic plasma and no change was induced by the injection. Subsequently, it was concluded that there was no erythropoietin of high titer in the plasma of chronic post-hemorrhagic anemic men.

  • PDF

Connection of Blobs along Post-CME Ray and EUV Flares

  • Kim, Yoojung;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.82.1-82.1
    • /
    • 2017
  • After a coronal mass ejection occur, plasma blobs are often observed along the post-CME ray. Searching for features related to the plasma blobs would be important in understanding their origin. We investigated the morphology of solar flares at EUV wavelengths, around the estimated times when blobs were formed. We focused on three events - 2013 September 21 and 22, 2015 March 7 and 8, and 2017 July 13 and 14 - observed by Atmospheric Imaging Assembly (AIA) aboard Solar Dynamic Observatory (SDO). Around the blob ejection times on 2013 September 21 and 22 and 2017 July 13 and14, we found regions with recurrent events of pronounced flux increase in EUV images. Around those of 2015 March 7 and 8, however, we could not observe such recurrent flux increase. This illustrates that even though blob ejections along different post-CME rays look similar in the high corona, the assocated features in the low corona may differ. We conclude that magnetic morphology and CME triggering process should be carefully examined in order to classify plasma blobs by their nature.

  • PDF

The Microstructures and Properties of Duplex Layer on the Tool Steel Formed by Post-oxidation and Sulfnitriding (금형공구강의 후산화와 침류질화에 의해 형성된 복합층의 조직과 특성에 관한 연구)

  • Lee, J.S.;Klm, H.G.;You, Y.Z.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.2
    • /
    • pp.81-88
    • /
    • 2001
  • The effects of post-oxidation and sulfnitriding treatments on the phase transformation in the nitrided case of tool steels have been studied. Dense and compact $Fe_3O_4$ layer was formed at the outer surface of nitride compound layer by post-oxidation treatment and multi layer of iron sulfide(FeS) was formed in the compound layer by sulfnitriding treatment. The surface hardness decreased because of formation of the soft oxide or sulfide at the nitride surface. Diffusion layer of nitride case was not affected by post-oxidation treatment or sulfnitriding treatment of nitrided alloy tool steels.

  • PDF

Effects of Antioxidant Vitamins Supplementation on Antioxidative Status and Plasma Lipid Profile in Korean NIDDM Patients (항산화비타민 보충이 인슐린비의 의존형 당뇨병 환자에서 항산화상태에 혈액지방성분에 미치는 영향)

  • 강남아
    • Journal of Nutrition and Health
    • /
    • v.32 no.7
    • /
    • pp.775-780
    • /
    • 1999
  • We investigated the effects of antioxidant vitamins supplementation on antioxidative status and plasma lipid profile in female Korean non-insulin diabetes mellitus(NIDDM) patients. Forty-five patients were groups by types of vitamin to take into three groups-Vitam in E group(400IU/day, n=15), Vitamin C group (1,000mg/day, n=15) and Vitamin E plus C group (400 IU plus 1,000mg/day). Supplementation period was 4 weeks. After vitamins supplementation, plasma vitamin E concentration significantly increased in vitamin E and vitamin E + C group, but plasma retinol concentration were not affected by vitamin E or vitamin C supplementation. And plasma levels of lipid peroxide measured as thiobarbituric acid reactive substances(TBARS), indicator of lipid peroxidation and increased susceptibility of LDL towards lipid peroxidation, were significantly decreased in all three groups after vitamins supplementation. Also catalase activities in erythrocytes were significantly decreased after antioxidant vitamin supplementation in all subjects. And after vitamins supplementation, post prandial 2 hour glucose and total cholesterol levels was decreased in all subjects. And after vitamins supplementation, post prandial 2 hour glucose and total cholesterol levels was decreased in all patients, especially there was a significant difference in vitamin C, Vitamin E + C group. In this study, antioxidant vitamins supplementation might have a protective function against the free radical-mediated lipid peroxidation and decrease the plasma total cholesterol levels in Korean female NIDDM patients.

  • PDF

Post-prandial decrease in plasma growth hormone levels is not related to the increase in plasma insulin levels in goats

  • Nishihara, Koki;Kobayashi, Ryoko;Suzuki, Yutaka;Sato, Katsuyoshi;Katoh, Kazuo;Roh, Sanggun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.12
    • /
    • pp.1696-1701
    • /
    • 2017
  • Objective: In the present study, we examined whether the post-prandial reduction in plasma growth hormone (GH) levels is related to the increase in plasma insulin levels in ruminants. Methods: We performed two experiments: intravenous bolus injection of insulin (0.2 IU/kg body weight) or glucose (1.0 mmol/kg body weight) was administered to increase the plasma insulin levels in male Shiba goats. Results: In the insulin injection experiment, significant (p<0.05) increase in GH concentrations was observed, 15 to 20 min after the injection; it was accompanied with a significant (p<0.01) increase in cortisol concentrations at 45 to 90 min, when compared to the concentrations in the saline-injected controls. The glucose injection significantly (p<0.05) increased the plasma GH concentration at 20 to 45 min; this was not accompanied by significantly higher cortisol concentrations than were observed for the saline-injected control. Hypoglycemia induced by the insulin injection, which causes the excitation of the adrenal cortex, might be involved in the increase in insulin levels. Conclusion: Based on these results, we conclude that post-prandial increases in plasma insulin or glucose levels do not induce a decrease in GH concentration after feeding in the ruminants.

Effects of Supplemental Glutamine on Growth Performance, Plasma Parameters and LPS-induced Immune Response of Weaned Barrows after Castration

  • Hsu, C.B.;Lee, J.W.;Huang, H.J.;Wang, C.H.;Lee, T.T.;Yen, H.T.;Yu, B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.5
    • /
    • pp.674-681
    • /
    • 2012
  • Two experiments were conducted to investigate the effects of supplemental glutamine on growth performance, plasma parameters and LPS-induced immune response of weaned barrows after castration. In experiment 1, forty-eight weaned male piglets were used and fed maize and soybean meal diets supplemented with 0 (Control) or 2% L-Gln (Gln+) for 25 days. The results indicated that the Gln+ group tended to increase average daily gain compared to control in stages of days 7 to 14 and 0 to 25. The Gln+ had significantly better feed efficiency than the control group did during days 14 to 25 and 0 to 25. The plasma blood urea nitrogen and alkaline phosphatase contents of Gln+ group were higher than those of the control group on day 14 post-weaning. In experiment 2, sixteen weaned male piglets were injected with E. coli K88+ lipopolysaccharide (LPS) on day 14 post-weaning. The results showed that the Gln+ group had lower concentrations of plasma adrenocorticotrophic hormone and cortisol than the control group on day 14 pre-LPS challenge. In addition, Gln+ group had higher plasma IgG concentration than the control group for pre- or post-LPS challenged on day 14 post-weaning. In summary, dietary supplementation of Gln was able to alleviate the stressful condition and inflammation associated with castration in weaned barrows, and to improve their immunity and growth performance in the early starter stage.

Pharmacokinetics of oxytetracycline in olive flounder (Paralichthys olivaceus) by dipping and oral administration (Oxytetracycline의 약욕 및 경구투여에 따른 넙치(Paralichthys olivaceus) 체내 약물동태학적 특성)

  • Jung, Sung-Hee;Choi, Dong-Lim;Kim, Jin-Woo;Jo, Mi-Ra;Seo, Jung-Soo;Jee, Bo-Young
    • Journal of fish pathology
    • /
    • v.21 no.2
    • /
    • pp.107-117
    • /
    • 2008
  • The pharmacokinetic properties of oxytetracycline (OTC) were studied after dipping and oral administration to cultured olive flounder, Paralichthys olivaceus (600 g). Plasma concentrations of OTC were determined after oral dosage (50, 100 and 200 mg/kg body weight) and dipping (50, 100 and 200 ppm, 1 h) in olive flounder (average 600 g, 23±1℃). Plasma samples were taken at 3, 5, 10, 15, 24, 32, 48, 72, 120, 168 and 240 h post-dose. In oral dosage of 50, 100 and 200 mg/kg, the peak plasma concentrations of OTC, which attained at 3 h post-dose, were 0.34, 0.44 and 1.18 ㎍/㎖, respectively. In dipping of 50, 100 and 200 ppm, those of OTC which also observed at 5 h post-dose, were 0.43, 0.38 and 0.64 ㎍/㎖, respectively. Plasma concentrations of OTC were not measurable at 240 h post-dose in all experiments. The kinetic profile of absorption, distribution and elimination of OTC in plasma were analyzed fitting to a one-compartment model by WinNonlin program. The following parameters were calculated for a single dosage of 50, 100 and 200 mg/kg body weight, respectively: AUC (the area under the concentration-time curve)=31.40, 28.07 and 32.97 ㎍∙h/㎖; T1/2 (half-life)􀆫0.89, 1.12 and 0.43 h; Tmax (time for maximum concentration)= 5.25, 3.70 and 7.30 h, Cmax (maximum concentration)=0.25, 0.38 and 0.61 ㎕/㎖. Following dipping at 50, 100 and 200 ppm, these parameters were AUC􀆫15.51, 14.63 and 19.72 ㎍∙h/㎖; T1/2= 0.75, 0.41 and 0.74 h; Tmax=4.90, 7.08 and 4.68 h, Cmax=0.40, 0.32 and 0.46 ㎕/㎖.