• Title/Summary/Keyword: Post curing

Search Result 140, Processing Time 0.03 seconds

Cure and Ethics Implied in Trauma Literature: Don DeLillo's Falling Man and Joy Kogawa's Obasan (외상문학에 함축된 치유와 윤리 -돈 드릴로의 『추락하는 남자』와 조이 코가와의 『오바상』 병치 연구)

  • Kim, Bong Eun
    • Journal of English Language & Literature
    • /
    • v.57 no.1
    • /
    • pp.107-127
    • /
    • 2011
  • Don DeLillo has shown considerable interest in terror, frequently depicting extreme dread of something terrible to happen, in his literary texts. Since more than three thousand innocent people in New York were killed by the 9-11 terrorist attack in 2001, the anticipation about what kind of fiction he would write as a New Yorker was high. DeLillo's novel Falling Man (2007) in fragmentary detail represents the scene of the terrorism from the perspective of Keith Neudecker, a lawyer who escapes the collapsing world trader center. Neudecker's post-traumatic stress disorder in the first chapter is followed by the free-associative portrayal of various impacts of the 9-11 terror on Neudecker's wife Lienne in the second chapter. The random mixture of the first person narratives from such diverse view-point characters as Neudecker's son Justin, relatives and friends, with dialogues and recollections yields a very close picture of the consequences of terrorism. Reading DeLillo's Falling Man in juxtaposition with a Japanese Canadian novel Obasan by Joy Kogawa, reminiscences of the maltreatment of Japanese Canadians during and after the second world war, surfaces the authorial intention of the two novels. They as trauma literature emerge to aim at curing the readers and proposing post-traumatic ethics. Laurie Vickroy's theory of trauma narrative and cure, E. Ann Kaplan's theory of trauma witness narrative and responsibility, and Emmanuel Levinas's theory of trauma memory and ethics offer theoretical grounds for the convincing analysis of the two texts.

Comparison of shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin (절삭 및 적층 가공법으로 제작한 임시 보철물 레진 블록과 재이 장용 자가중합 레진의 전단결합강도 비교)

  • Hyo-Min Ryu;Jin-Han Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.189-197
    • /
    • 2023
  • Purpose. This study aimed to compare and evaluate the shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin. Materials and methods. The experimental groups were divided into 4 groups according to the manufacturing methods of the resin block specimens and each specimen was fabricated by subtractive manufacturing (SM), additive manufacturing stereolithography apparatus manufacturing (AMS), additive manufacturing digital light processing manufacturing (AMD) and conventional self-curing (CON). To bond the resin block specimens and self-curing resin, the reline resin was injected and polymerized into the same location of each resin block using a silicone mold. The shear bond strength was measured using a universal testing machine, and the surface of the adhesive interface was examined by scanning electron microscopy. To compare between groups, one-way ANOVA was done followed by Tukey post hoc test (α = 0.05). Results. The shear bond strength showed higher values in the order of CON, SM, AMS, and AMD group. There were significant differences between CON and AMS groups, as well as between CON and AMD groups. but there were no significant differences between CON and SM groups (P > .05). There were significant differences between SM and AMD groups, but there were no significant differences between SM and AMS groups. The AMS group was significantly different from the AMD group (P < .001). The most frequent failure mode was mixed failures in CON and AMS groups, and adhesive failures in SM and AMD groups. Conclusion. The shear bond strength of SM group showed lower but not significant bond strength compared to the CON group. The additive manufacturing method groups (AMS and AMD) showed significantly lower bond strength than the CON group, with the AMD group the lowest. There was also a significant difference between the AMD and SM group.

Photopolymer Composed of a Photosensitive Polymer Binder Bearing a Chalcone Moiety in the Repeating Unit

  • Cho, Min-Ju;Yoon, Hyuk;Feng, Dejun;Yoon, Han-na;Choi, Dong-Hoon
    • Journal of Information Display
    • /
    • v.7 no.2
    • /
    • pp.6-11
    • /
    • 2006
  • New photopolymers were designed and prepared using the photosensitive polymer binders. Holographic gratings were successfully fabricated in these photopolymer samples by a conventional optical interference method. We also investigated the effect of photocrosslink in the polymer binder on the diffraction behavior of a new photopolymer. The dynamic behavior of the grating formation was monitored by changing exposure intensity in terms of the diffraction efficiency. Particularly, we focused our efforts in observing the variation of diffraction efficiency during a post UV curing process. The surface topographical change of photopolymer layer before and after Vis/UV light exposure was observed by atomic force microscope (AFM). We inscribed the gratings of the glass diffuser on the surface of the photopolymer and investigated their diffusing properties. The diffusers with photopolymer with the main chain polymer binder showed relatively good viewing angle of around ${\pm}30{\circ}$. Two kinds of photopolymer showed similar uniformity of around 47-54%.

Heating & Drying Characteristics of Coating Layer by Induction Heating and Short-wave Infrared Heating (유도가열 및 근적외선 가열방법에 의한 표면처리 강판 도포층의 가열 및 건조 특성)

  • Kim T. S.;Yang J. W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.249-257
    • /
    • 2004
  • Drying and curing characteristics of PCM resins using the induction heater and short-wave infrared emitter module was studied to develop a compact oven system for the high speed CCL and post-treatment equipment. Drying of the polyester resins using the induction heater and infrared heater showed that the blistering tendency of polyester resin coating increased regardless of additives and colors of resins as the heating rate and/or dry film thickness increased. The blistering of polyester resin coating layer occurred when the heating speed was over than $25^{\circ}C/sec$ for the dry film thickness of $19\~20um$, which is the typical thickness of finish coating in CCL. So did it when the heating speed was over than $40^{\circ}C/sec$ for the dry film thickness over than 10 um. The heating efficiency of paint coated steels by the infrared heating was strongly dependent on the colors of paint coating and generally increased for the dark surface and/or coating. But the faster drying of the PCM resin coatings increased the blistering tendency of coating layer. The blistering limit for the typical finish coating by the infrared heating was estimated as the heating rate slower than $20^{\circ}C/sec$ regardless of colors of PCM resins.

  • PDF

Verification Studies for Field Peformance of Micropiling (성능검증을 위한 마이크로파일 현장 시험시공 및 재하시험)

  • Goo, Jeong-Min;Lee, Ki-Hwan;Cho, Young-Jun;Choi, Chang-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.368-375
    • /
    • 2009
  • This paper describes field installation and load test results performed for three types of micropiles in the process of developing a new micropiling method. Field tests were performed for two conventional types(i.e., micropile reinforced with steel bar and gravity grouting, micropile reinforced with steel bar and steel casing and gravity grouting) and a proposed type(i.e., micropile reinforced with hollow steel pipe wrapped with geotextile-pack and pressurized grouting). The load test results subjected to axial compression and tension and lateral loading conditions are described in this paper. The micropiles were exposed in the air in order to verify the installation quality and curing condition of grouting material via ground excavation. Axial compression and tension test results indicate that the new micropile type provide at least 40% higher bearing capacity than that of conventional types. Based on the examination of exposed piles, it is induced that the proposed method, packed micropile, provides better interlocking between grouts and surrounding soils and increases higher frictional resistance comparing to conventional types.

  • PDF

A study on the system improvement policy according to the status analysis of medical device control system in Korea (국내 의료기기관리제도의 현황분석에 따른 정책적 제도개선 방안에 관한 연구)

  • Lee, Kyung-Man;Baek, Nak-Ki;Seo, Jong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.37-52
    • /
    • 2010
  • This study is aimed at proposing the national policy for medical device control system in Korea as deeply analysed the present status of the system. On 1979, Korean government had started to inspect 24 kinds of the medical devices such as X-ray diagnostic equipments, medical sterilizer and etc. mostly imported from advanced countries which USA, Germany and Japan for the first time according to the Pharmaceutical Affairs Law. However medical devices were becoming consideration as an important partner of diagnosis, curing and alleviation of diseases by medical doctors and also much important keeping the health at home. Furthermore medical devices industry can be designated as a national growth engine industry. So it is necessary not only to harmonize to international standards but also the harmonization of the system including pre-market application and post-market surveillance, is strongly needed by the Korea Food and Drugs Administration(KFDA).

Failure Paths of Polymer/Roughened Metal Interfaces under Mixed-Mode Loading (혼합 하중하에서의 고분자/거친금속 계면의 파손경로)

  • Lee Ho-Young;Kim Sung-Ryong
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.322-327
    • /
    • 2004
  • Copper-based leadframe sheets were oxidized in two kinds of hot alkaline solutions to form brown-oxide or black-oxide layer on the surface. The oxide coated leadframe sheets were molded with epoxy molding compound (EMC). After post mold curing, the oxide-coated EMC-leadframe joints were machined to form sandwiched Brazil-nut (SBN) specimens. The SBN specimens were used to measure the fracture toughness of the EMC/leadframe interfaces under mixed-mode (mode I + mode II) loading conditions. Fracture surfaces were analyzed by various equipment to investigate failure path. The results revealed that the failure paths were strongly dependent on the oxide type. In case of brown oxide, hackle-type failure was observed and failure path lay near the EMC/CuO interface with a little inclining to CuO at all case. On the other hand, in case of black oxide, quite different failure path was observed with respect to the distance from the tip of pre-crack and phase angle. Different failures occurred with oxide type is presumed to be due to the difference in microstructure of the oxides.

Development of Eco-friendly Basalt Fiber-reinforced Furan-based Composite Material with Improved Fire and Flame Retardants for Shipbuilding and Offshore Pipe Insulation Cover (조선해양 파이프 단열재 커버 적용을 위한 내화/난연 성능을 갖는 친환경 바잘트섬유 강화 퓨란계 복합재료 개발 연구)

  • Kwon, Dong-Jun;Seo, Hyoung-Seock
    • Composites Research
    • /
    • v.34 no.1
    • /
    • pp.57-62
    • /
    • 2021
  • As interest in the eco-friendly ships and lightweight equipment is increasing in the shipbuilding and marine industry, composite materials are applied to equipment such as pipes. In this study, a basalt fiber reinforced furan composite (BFC), an eco-friendly material, was manufactured to apply the pipe insulation cover that requires environment-friendly and heat/flame retardant performance. An optimization study of post-curing conditions of BFC was conducted, and experiments and analysis were performed on mechanical strength, heat/flame retardant properties, and affinity properties. Finally, as a result of the study BFC material is proved to be a good candidate to apply pipe insulation cover.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Thermal Stability and Cure Behavior of Waterborne Phenol-Formaldehyde Resin (수용성 페놀-포름알데히드 수지의 열안정성 및 경화거동)

  • Yoon, Sung Bong;Kim, Jin Woo;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.7 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • In this work, the effect of cure temperature and time on the thermal stability and the exothermic cure reaction peak of a waterborne resol-type phenol-formaldehyde resin, which may be used for preparing phenolic sheet molding compounds (SMC), has been investigated using a thermogravimetric analyzer and a differential scanning calorimeter. The weight loss of waterborne phenol-formaldehyde resin was mainly occurred at three temperature stages: near $200^{\circ}C,\;400^{\circ}C$, and $500^{\circ}C$. The carbon yield at $750^{\circ}C$ for the cured resin was about 62%~65%. Their thermal stability increased with increasing cure temperature and time. Upon cure, the exothermic reaction was taken placed in the range of $120^{\circ}C{\sim}190^{\circ}C$ and the maximum peak was found in between $165^{\circ}C$ and $170^{\circ}C$. The shape and the maximum of the exothermic curves depended on the given cure temperature and time. To remove $H_2O$ and volatile components, the uncured resin needed a heat-treatment at $100^{\circ}C$ for 60 min at least prior to cure or molding. Curing at $130^{\circ}C$ for 120 min made the exothermic peak of waterborne phenol-formaldehyde resin completely disappeared. And, post-curing at $180^{\circ}C$ for 60 min further improved the thermal stability of the cured resin.

  • PDF