• Title/Summary/Keyword: Post and composite core

Search Result 60, Processing Time 0.03 seconds

Fracture resistance of upper central incisors restored with different posts and cores

  • Rezaei Dastjerdi, Maryam;Amirian Chaijan, Kamran;Tavanafar, Saeid
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Objectives: To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. Materials and Methods: Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1), fiber-reinforced composite (FRC) post and composite core (group 2), composite post and core (group 3), and controls (group 4). Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4). Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at $135^{\circ}$ vertical angle, subjected to thermo-mechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. Results: Fracture resistance of the groups was as follows: Control (group 4) > cast post and core (group 1) > fiber post and composite core (group 2) > composite post and core (group 3). All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58%) in group 1 were non-restorable. Conclusions: Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.

A STUDY OF THE MICROLEAKAGE AT THE POST AND CORE AND TOOTH INTERFACE (포스트 코아와 치근 계면에서의 미세누출에 관한 연구)

  • Shin, Ji-Cheol;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.366-378
    • /
    • 1998
  • Post and core is used to restore endodontically treated teeth, and it is a very important part which supplies retention and support to the prosthesis. But occasionally, caries occured due to the microleakage at the post and core and tooth interface, the failure of prosthesis has happened. In this study, the microleakage of cast gold post and core, amalgam core, and composite resin core was investigated and compared. The coronal part of the extracted upper anterior teeth were removed and endodontically treated with conventional method. The teeth were divided into three groups. In group 1, cast gold post and core was cemented with resin cement and in group 2, ready-made post was cemented with resin cement and amalgam core was built. In group 3, ready-made post was cemented with resin cement and composite resin core was built. All specimens were thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ with dwell time of 15 seconds, and immersed in 0.5% aqueous solution of basic fuchsin dye for 24 hours. After embedded in the epoxy resin, the specimens were sectioned longitudinally and observed with stereomicroscope with the magnification of 25. From the findings of this study, the following conclusions were obtained. 1. There was microleakage at the core/tooth interface of all specimens. 2. The microleakage of gold post and core was significantly less than those of the other two groups. 3. There was no significant difference between the microleakage of amalgam core and that of composite resin core.

  • PDF

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.

Comparative evaluation of effects of different surface treatment methods on bond strength between fiber post and composite core

  • Mosharraf, Ramin;Yazdi, Najmeh Baghaei
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • PURPOSE. Debonding of a composite resin core of the fiber post often occurs at the interface between these two materials. The aim of this study was to evaluate the effects of different surface treatment methods on bond strength between fiber posts and composite core. MATERIALS AND METHODS. Sixty-four fiber posts were picked in two groups (Hetco and Exacto). Each group was further divided into four subgroups using different surface treatments: 1) silanization; 2) sandblasting; 3) Treatment with 24% $H_2O_2$, and 4) no treatment (control group). A cylindrical plexiglass matrix was placed around the post and filled with the core resin composite. Specimens were stored in 5000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$. Tensile bond strength (TBS) test and evaluation using stereomicroscope were performed on the specimen and the data were analyzed using two-way ANOVA, Post Hoc Scheffe tests and Fisher's Exact Test (${\alpha}$=.05). RESULTS. There was a significant difference between the effect of different surface treatments on TBS ($P$ <.001) but different brands of post ($P$=.743) and interaction between the brand of post and surface treatment ($P$=.922) had no significant effect on TBS. Both silanization and sandblasting improved the bonding strength of fiber posts to composite resin core, but there were not any significant differences between these groups and control group. CONCLUSION. There was not any significant difference between two brands of fiber posts that had been used in this study. Although silanization and sandblasting can improve the TBS, there was not any significant differences between surface treatments used.

A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST (Glass Fiber Post와 Composite Resin Core의 전단결합강도)

  • Kim Tae-Hyoung;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

A COMPARISON OF POST AND CORE TECHNIQUES WITH FINITE ELEMENT ANALYSIS (유한요소법에 의한 Post와 Core 형성법의 비교)

  • Cheong, Yong-Kee;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.70-86
    • /
    • 1996
  • The purpose of this study was to analyze the stress distribution in mandibular second premolars restored with different post and core techniques. Sixteen two-dimensional finite element model of mandibular second premolars restored with post and core and complete crown were developed according to the diameter, length, and material of post and core. Vertical force, 10N in magnitude, was applied first to the central fossa and then $45^{\circ}$ oblique force of same magnitude was applied to the buccal contact surface of buccal cusp. The obtained results were as follows : 1. Stress distribution within the dentin 1) Regardless of the material of the post and core and the diameter and length of the post, the pattern of stress distribution within the dentin was similar. 2) Maximum dentinal stress was observed on the lingual root surface of alveolar crest level with oblique loading and on lingual side of root dentin at the crown margin on vertical loading. 3) Cast post and cores produced the lowest dentinal stress concentrations and the highest stress concentration was observed in composite resin post and cores. 2. Stress distribution within the post and core 1) Within the amalgam and composite resin post and core, the patterns and maximum values of stress were similar. Maximum stress located at the central fossa of core portion on vertical loading and at the lingual junction of post and core with oblique loading. 2) Among the all post and cores, the cast post and core registered the highest stress concentration and maximum stress value within the post. Maximum stress located at the post apex on vertical loading and at lingual half of the post surface with oblique loading. 3) In case of Para-post and amalgam core, maximum stress located at the central fossa of core portion and lingual tip of the post head on vertical loading. With oblique loading, maximum stress located at the lingual half of the post surface.

  • PDF

FINITE ELEMENT ANALYSIS OF THE INFLUENCE OF ESTHETIC POSTS ON INCISORS (심미 포스트가 전치에 미치는 응력과 변위에 관한 삼차원 유한요소법적 분석)

  • Kwon Tae-Hoon;Hwang Jung-Won;Kim Sung-Hun;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.582-595
    • /
    • 2003
  • Statement of problem : Most posts are metallic, but in response to the need for a post that possesses optical properties compatible with an all-ceramic crown. an esthetic post has been developed. Although there have been many studies about the esthetic post materials, 3-dimensional finite element studies about the stress distribution of them are in rare. Purpose : The purpose of this study is to investigate comparatively the distribution of stresses of the restored, endodontically treated maxillary incisors with the esthetic post materials and the displacement on the cement layer on simulated occlusal loading by using a 3-dimensional finite element analysis model. Material and method : Four 3-dimensional finite element models were constructed in a view of a maxillary central incisor, a post, a core, and the supporting tissues to investigate the stresses in various esthetic posts and cores and the displacement on the cement layer (Model 1 ; Cast gold post and core, Model 2 ; Glass fiber post with composite core, Model 3 ; Zirconia post with composite core. Model 4 ; Zirconia post with ceramic core). Force of 300N was applied to the incisal edge and the cingulum (centric stop point) with the angle of 135-degree to the long axis of the tooth. Results : 1. The stresses and displacement on the incisal edge were higher than on the cingulum 2. The stresses in dentin were the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. 3. The stresses in post and core were the highest in Model 4 (Zirconia post with ceramic core), and the second was Model 1, the third Model 3, and the lowest Model 2. 4. The displacement on the cement layer was the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. Conclusion : When a functional maximum bite force was applied, the distribution of stresses or the esthetic post and core materials and the displacement on the cement layer were a little different. It seems that restoring extensively damaged incisors with esthetic post and core materials would be decided according to the remaining tooth structure.

A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study

  • Makade, Chetana S.;Meshram, Ganesh K.;Warhadpande, Manjusha;Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • PURPOSE. To compare the fracture resistance and the mode of failure of endodontically treated teeth restored with different post-core systems. MATERIALS AND METHODS. Root canal treatment was performed on 40 maxillary incisors and the samples were divided into four groups of 10 each. For three experimental groups post space preparation was done and teeth were restored with cast post-core (Group B), stainless steel post with composite core (Group C) and glass fiber post with composite core using adhesive resin cement (Group D). Control group (A) samples were selected with intact coronal structure. All the samples were prepared for ideal abutment preparation. All the samples were subjected to a load of 0.5 mm/min at $130^{circ}$.until fracture occurred using the universal testing machine. The fracture resistance was measured and the data were analyzed statistically. The fracture above the embedded resin was considered to be favorable and the fracture below the level was considered as unfavorable. The statistical analysis of fracture resistance between different groups was carried out with t-test. For the mode of failure the statistical analysis was carried out by Kruskal-Wallis test and Chi-Square test. RESULTS. For experimental group Vs control group the fracture resistance values showed significant differences (P<.05). For the mode of failure the chi-square value is 16.1610, which means highly significant (P=.0009) statistically. CONCLUSION. Endodontically treated teeth without post core system showed the least fracture resistance demonstrating the need to reinforce the tooth. Stainless steel post with composite core showed the highest fracture resistance among all the experimental groups. Teeth restored with the Glass fiber post showed the most favorable fractures making them more amenable to the re-treatment.

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

FRACTURE STRENGTH AND FRACTURE MODE OF RESIN ROOT ANALOGS RESTORED WITH VARIOUS POST AND CORE MATERIALS

  • Lee, Byung-Chul;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.287-295
    • /
    • 2002
  • Statement of Problem. Endodontically treated teeth frequently required posts and cores to provide retention and resistance form for crowns. In spite of excellent mechanical properties of metal post and core, its metallic color can be detected through all ceramic restorations occasionally. To solve esthetic problems of metal post and core zirconia post system has been introduced recently. Purpose. The purpose of this study was to examine the fracture strength and mode of resin root analogs restored with zirconia, gold and titanium posts with resin, ceramic and metal cores after cementation with metal crowns. Materials and methods. To avoid the morphological variations of natural teeth, 40 root analogs were fabricated with composite resin. Forty resin root analogs were randomly assigned to four groups according to post and core materials: Group A: cast gold post and core and complete cast crowns, as control. Group B: titanium posts (Parapost, Coltent/Whaledent Inc., NJ, USA) and composite resin cores. Group C: zirconia posts (Cosmopost, Ivoclar AG, Schaan/Liechtenstein) and composite resin cores Group D: zirconia posts and heat-pressed ceramic cores (IPS Empress Cosmo Ingots, Ivoclar AG) After thermocycling ($5^{\circ}C{\sim}55^{\circ}C$, 30 sec.), cyclic loading was applied at 3mm below the incisal edge on the palatal surfaces at an angle of 135 degree to the long axis (2Hz, 50N, 50000cycles). Fracture strength was measured by universal testing machine (Instron, High Wycombe, UK) and fracture pattern of restored resin root analogs was also evaluated. Results and conclusion. Within the limitations of this study following results were drawn. 1. Resin root analogs restored with zirconia posts and composite resins demonstrated lowest fracture strength among tested groups. 2. There was no significant difference in the fracture strength between zirconia posts and heat pressed glass ceramic cores and cast gold posts and cores 3. The fracture strength of resin root analogs restored with titanium posts and composite resin cores was lower than that of gold posts and cores. 4. The deep oblique fracture lines were dominantly observed in root analogs restored with cast gold post and core and zirconia post and heat-pressed ceramic core groups.