• Title/Summary/Keyword: Possibility of a fire

Search Result 317, Processing Time 0.032 seconds

Prediction for Possibility of the Electric Fire by Tracking Breakdown (트래킹에 의한 전기화재 가능성 예측)

  • Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • Tracking, which is one of main reasons of the electric fire, progresses gradually, and therefore, the possibility of fire caused by tracking can be predicted by analyzing the stage of its progress. This paper is conducted in order to predict possibility of the electric fire caused by the tracking in the simulated electric equipment with load. Non-inductive resistance is used as the load. The tracking is happened in a Polyvinyl-chloride-sheathed flat cord, which is a part of the simulated electric equipment by means of dropping of electrolyte droplet. In order to predict the possibility of electric fire caused by tracking, we detect the whole current waveforms of the simulated electric equipment. The time-energy analysis and probability distribution are used for analysis of the tracking progress from the whole current waveforms. In accordance with the results is used for input date of Neural networks, the neural networks can be predict possibility of the electric fire in the electric equipment by 4 stages.

A Study on the Risk of Fire Caused by Sparks during Grinding Operation (그라인딩 작업 중 발생하는 불티의 화재 예방에 관한 연구)

  • Seong-En Kim;Geun-Chul Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.751-756
    • /
    • 2023
  • In this study, We investigated a fire case and performed an experiment to prevent fire from sparks that is generated during grinding operation. Before conduct the test, confirmed that the generating mechanism of fire-flakes in working grinder and the fire experiment was conducted using commonly tools, flammable materials in industrial field. in result, It could be measured scattering distance, temperature, ignition possibility by type of combustible materials. Based on the results of this study, We are expected to be used as basic data for fire prevention in grinding Industry.

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space (밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구)

  • Jeon, Kil Song;Hwang, Ji Hyun;Lee, Tea Won
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.

A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring (옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구)

  • Kim, Doo-Hyun;Kim, Eun-Jin;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

A Study on the Spontaneous Ignition Possibility of Shredded Waste Thermoplastic Elastomer (폐 열가소성 플라스틱 탄성체 분쇄물의 자연발화가능성에 관한 연구)

  • Park, Young Ju;Lee, Hae Pyeong;Goh, Kyoung Chun;Eom, Young Sup
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • In this study, we considered the ignition possibility for the shredded thermoplastic elastomer at the fire ground loaded the waste TPE. The average moisture content of the TPE sample was almost 0.33 wt.% at $110^{\circ}C$ and the range of ignition point was $461.9{\sim}491.9^{\circ}C$ approximately. In addition, we analyzed the change of weight and calorie the TPE sample according to temperature variations using the TG-DTA analyzer. As a result, the weight loss occurred twice in $250{\sim}420^{\circ}C$ and $420{\sim}473^{\circ}C$, and we found the second weight loss temperature range was the ignition point of TPE. Also, we conducted the spontaneous ignition tests of TPE for the wet and dry samples and we confirmed that the possibility of spontaneous ignition of TPE was very low. The elapsed time and humidity had little influence on the spontaneous ignition of TPE in this experimental conditions. In conclusion, the spontaneous of the shredded waste TPE in this study.

Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model (화재 상황 인식 모델을 적용한 종합 상황 판단 시스템)

  • Song, Jae-Won;Lee, Se-Hee;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

A Case Study on the Lights Fire(Focus on the Electric Bulbs and Fluorescent Lamps) (조명등 화재사례 연구(전구 및 형광등 중심으로))

  • Song, T.H.;Lee, E.P.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.41-58
    • /
    • 2008
  • The history of illumination has been much long since the discovery of lamplight caused huge changes in human lives. However, the swift development of the illumination actually started with the invention of a carbon filament lamp by Thomas Edison in 1878. Generally, the illumination tools plays important roles in human lives such as reduction of fatigue, improvement of safety and working efficiency, and the creation of enjoyable atmosphere. But, the illumination tools can be an origin of the fire due to carelessness and lack of management. In this study, the principle and structure of the illumination lamp were dealt with. The possibility of the fire outbreak caused by the incandescent lamp and fluorescent lamp most used in home was investigated. The examples of the fire outbreaks by the incandescent and fluorescent lamps and by the contact between the inflammable materials and the distributing wires were mentioned and demonstrated by the experimental.

  • PDF