• Title/Summary/Keyword: Positron emitter

Search Result 7, Processing Time 0.018 seconds

Radiopharmaceuticals for Imaging of Cellular Proliferation (세포 증식 영상용 방사성의약품)

  • Oh, Seung-Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.209-223
    • /
    • 2002
  • By considering the biological properties of a tumor, it should be possible to realize better results in cancer therapy. PET imaging offers the opportunity to measure tumor growth non-invasively and repeatedly as an early assessment of response to cancer therapy. Measuring cellular growth instead of energy metabolism showed offer significant advantages in evaluating therapy. Thymidine and its derivative nucleoside compounds can be changed to mono, di- and tri- phosphate compounds by thymidine kinase and then be incorporated into DNA. Their bindings are increased in highly proliferating cells due to the high DNA synthesis rate. To evaluate cell proliferation, many kinds of thymidine and uridine derivatives have been labeled with positron emitter and radioactive iodine. Compared to radiopharmaceuticals which have radioisotope labeled base ring such as pyirmidine, the radiopharmacuticals which have radioisotope labeled sugar ring are more stable in vivo and have metabolic resistance. The biological properties such as DNA incorporation ratios are highly dependent on their chemical structures and metabolic processes. This overview describes synthesis of radiopharmaceuticals and their biological properties for imaging of tumor cell proliferation.

Positron Annihilation Lifetime Study on the Proton-Irradiation BaSrFBr : Eu Film (양전자 소멸 수명 측정에 의한 양성자 조사된 BaSrFBr : Eu 박막 특성)

  • Im, Yu-Suk;Lee, Chong-Yong
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • Positron annihilation lifetime spectroscopy is applied to BaSrFBr : Eu film which is used for the phosphore layer, and afterwards the reliability and self-consistency of source corrections in the positron lifetime spectroscopy is investigated using a $^{22}Na$ positron emitter covered by thin foils. The positron lifetime showed no significant change through the various proton irradiation energies. It is unusual that the measurements of the defects indicate that most of the defects were likely to have been generated by X-ray radiation. This may have resulted from the Bragg peaks of the proton characteristics. The Bragg peak does not affect the defect signals enough to distinguish the lifetimes and intensities in a material that is includes multi-grains. The lifetime ($\tau_1$) associated with positron annihilations in the Ba, Br, and Eu of the sample was about 250 ps, and due to the annihilations at F-centers or defects from the irradiated protons in sample, the lifetime ($\tau_2$) was about 500 ps.

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

Study of occupational exposure in PET/CT (PET/CT 종사자의 방사선피폭에 관한 연구)

  • Na, Soo-Kyung;Park, Byung-Sub;Kang, Yong-Gil
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.449-457
    • /
    • 2012
  • The purpose of this study is to investigate the relationship between radiation origin and health professionals, and to reduce exposed dose of radiation through efficient management. Increasing exposed dose of radiation to health professionals are caused by the increase of PET/CT use and a radioactive isotope. Hence, in this study, space dose from each origin of radiation generating was analyzed and the use of personnel protective clothing and shields was compared. As a result of this study, we confirmed that the exposed dose of radiation was much higher in case of wearing personnel protective clothing(0.5 mm pb) than no wearing personnel protective clothing under high energy gamma radiation(511 keV) of the position emitter($^{18}F$).

Dose Distribution of $^{11}C$ Beams for Spot Scanning Radiotherapy

  • Urakabe, Eriko;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Noda, Koji;Tomitani, Takehiro;Suda, Mitsuru;Mizuno, Hideyuki;Iseki, Yasushi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.202-205
    • /
    • 2002
  • This paper describes the spot scanning with $^{11}$ C beams for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The concave-shaped irradiation field was optimized and the dose distribution was measured by 128-ch ionization chamber. Because of the wide momentum spread inherent in $^{11}$ C beams, the dispersion caused from the beam line and the scanning magnets should be taken into account to calculate the dose distribution of $^{11}$ C beams and their irradiated field. The reconstructed dose distribution is in good agreement with the experimental results.

  • PDF

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Preliminary studies for production of 61Cu using natural nickel target with RFT-30 cyclotron

  • Lee, Jun Young;Hur, Min Goo;Yang, Seung Dae;Park, Jeong Hoon
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.79-82
    • /
    • 2019
  • 61Cu is a promising PET radiometal having favorable nuclear decay characteristics with appropriate half-life of 3.3 h. Owing its promising capabilities in radiopharmaceutical chemistry and its chemical similarities with its isotopes 64Cu and 67Cu, in this work we have tried to optimize the production and separation conditions of 61Cu. 61Cu was produced via (p, x) reaction with natural nickel which was electroplated on the high purity silver coated copper backing target holder. The optimization of target electrodeposition, beam energy and current modulation, target dissolution and separation were optimized in this study. Preliminary studies show that 61Cu was successfully produced and separated which can be further extended for the production of 64Cu and 67Cu.