• 제목/요약/키워드: Positron emitter

검색결과 7건 처리시간 0.02초

세포 증식 영상용 방사성의약품 (Radiopharmaceuticals for Imaging of Cellular Proliferation)

  • 오승준
    • 대한핵의학회지
    • /
    • 제36권4호
    • /
    • pp.209-223
    • /
    • 2002
  • By considering the biological properties of a tumor, it should be possible to realize better results in cancer therapy. PET imaging offers the opportunity to measure tumor growth non-invasively and repeatedly as an early assessment of response to cancer therapy. Measuring cellular growth instead of energy metabolism showed offer significant advantages in evaluating therapy. Thymidine and its derivative nucleoside compounds can be changed to mono, di- and tri- phosphate compounds by thymidine kinase and then be incorporated into DNA. Their bindings are increased in highly proliferating cells due to the high DNA synthesis rate. To evaluate cell proliferation, many kinds of thymidine and uridine derivatives have been labeled with positron emitter and radioactive iodine. Compared to radiopharmaceuticals which have radioisotope labeled base ring such as pyirmidine, the radiopharmacuticals which have radioisotope labeled sugar ring are more stable in vivo and have metabolic resistance. The biological properties such as DNA incorporation ratios are highly dependent on their chemical structures and metabolic processes. This overview describes synthesis of radiopharmaceuticals and their biological properties for imaging of tumor cell proliferation.

양전자 소멸 수명 측정에 의한 양성자 조사된 BaSrFBr : Eu 박막 특성 (Positron Annihilation Lifetime Study on the Proton-Irradiation BaSrFBr : Eu Film)

  • 임유석;이종용
    • 한국재료학회지
    • /
    • 제20권6호
    • /
    • pp.307-311
    • /
    • 2010
  • Positron annihilation lifetime spectroscopy is applied to BaSrFBr : Eu film which is used for the phosphore layer, and afterwards the reliability and self-consistency of source corrections in the positron lifetime spectroscopy is investigated using a $^{22}Na$ positron emitter covered by thin foils. The positron lifetime showed no significant change through the various proton irradiation energies. It is unusual that the measurements of the defects indicate that most of the defects were likely to have been generated by X-ray radiation. This may have resulted from the Bragg peaks of the proton characteristics. The Bragg peak does not affect the defect signals enough to distinguish the lifetimes and intensities in a material that is includes multi-grains. The lifetime ($\tau_1$) associated with positron annihilations in the Ba, Br, and Eu of the sample was about 250 ps, and due to the annihilations at F-centers or defects from the irradiated protons in sample, the lifetime ($\tau_2$) was about 500 ps.

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

PET/CT 종사자의 방사선피폭에 관한 연구 (Study of occupational exposure in PET/CT)

  • 나수경;박병섭;강용길
    • 디지털융복합연구
    • /
    • 제10권11호
    • /
    • pp.449-457
    • /
    • 2012
  • 본 연구의 목적은 PET/CT 검사시 공간선량을 측정 비교함으로써 방사선 발생원과 종사자간 선량의 상관관계를 규명하고 효율적인 관리를 통해 피폭선량을 감소시키는데 있다. 최근 PET/CT 검사의 증가는 동위원소 사용량의 증가와 더불어 종사자의 피폭 증가의 원인이 되고 있다. 따라서 각 방사선 발생원에서의 공간선량을 비교 분석하고 개인방호복과 차폐체 사용에 관한 연구를 수행하였다. 양전자 방출핵종인 $^{18}F$ 방출 감마선 고에너지(511 keV)에서 개인방호복(0.5 mm pb) 사용은 미사용 시 보다 더 많은 피폭을 초래함을 확인하였다.

Dose Distribution of $^{11}C$ Beams for Spot Scanning Radiotherapy

  • Urakabe, Eriko;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Noda, Koji;Tomitani, Takehiro;Suda, Mitsuru;Mizuno, Hideyuki;Iseki, Yasushi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.202-205
    • /
    • 2002
  • This paper describes the spot scanning with $^{11}$ C beams for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The concave-shaped irradiation field was optimized and the dose distribution was measured by 128-ch ionization chamber. Because of the wide momentum spread inherent in $^{11}$ C beams, the dispersion caused from the beam line and the scanning magnets should be taken into account to calculate the dose distribution of $^{11}$ C beams and their irradiated field. The reconstructed dose distribution is in good agreement with the experimental results.

  • PDF

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • 대한방사성의약품학회지
    • /
    • 제5권2호
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Preliminary studies for production of 61Cu using natural nickel target with RFT-30 cyclotron

  • Lee, Jun Young;Hur, Min Goo;Yang, Seung Dae;Park, Jeong Hoon
    • 대한방사성의약품학회지
    • /
    • 제5권2호
    • /
    • pp.79-82
    • /
    • 2019
  • 61Cu is a promising PET radiometal having favorable nuclear decay characteristics with appropriate half-life of 3.3 h. Owing its promising capabilities in radiopharmaceutical chemistry and its chemical similarities with its isotopes 64Cu and 67Cu, in this work we have tried to optimize the production and separation conditions of 61Cu. 61Cu was produced via (p, x) reaction with natural nickel which was electroplated on the high purity silver coated copper backing target holder. The optimization of target electrodeposition, beam energy and current modulation, target dissolution and separation were optimized in this study. Preliminary studies show that 61Cu was successfully produced and separated which can be further extended for the production of 64Cu and 67Cu.