• Title/Summary/Keyword: Positron Emission Tomography(PET)

Search Result 471, Processing Time 0.034 seconds

Neuroimaging Assessment of the Therapeutic Mechanism of Acupuncture and Bee Venom Acupuncture in Patients with Idiopathic Parkinson's Disease: A Double-blind Randomized Controlled Trial

  • Young-Eun Lee;Seung-Yeon Cho;Han-Gyul Lee;Seungwon Kwon;Woo-Sang Jung;Sang-Kwan Moon;Jung-Mi Park;Chang-Nam Ko;Seong-Uk Park
    • The Journal of Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.104-120
    • /
    • 2023
  • Objectives: The purpose of this study was to explore the therapeutic mechanism of acupuncture and bee venom acupuncture (BVA) in patients with idiopathic Parkinson's disease (IPD) using positron emission tomography (PET) and arterial spin labeling (ASL). Methods: Patients with IPD who received a stable dose of anti-parkinsonian medication for at least 4 weeks were recruited and randomly divided into one of two groups: treatment and control. The treatment group (11 subjects) received acupuncture and BVA at acupoints, and the control group (9 subjects) received sham acupuncture and normal saline injections at non-acupoints, twice per week for 12 weeks. The patients were examined using PET and ASL at baseline and after the 12-week treatment. In addition, age- and sex-matched healthy subjects without neurological symptoms and history were recruited to compare ASL data of patients with IPD. Results: PET results revealed that striatal dopamine transporter binding increased in each group after 12 weeks. Although the change was larger in the treatment group, the difference was not statistically significant. In ASL results, the treatment group exhibited hyperperfusion in specific regions compared with the healthy control group. After 12 weeks' intervention, hyperperfusion regions were recovered only in the treatment group. In contrast, significant changes were not found in hyperperfusion regions in the control group after 12 weeks. Conclusions: Our findings suggest that the therapeutic mechanisms of acupuncture and BVA in IPD are different from placebo and operate by altering dopamine availability and recovering hyperactivity in cerebral blood flow.

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Analysis on the association between EEG and 2-deoxy-2-[18F]-D-glucose (FDG)-PET findings in children with epilepsy (소아 간질 환아에서 뇌파와 PET과의 연관성에 대한 분석)

  • Hur, Yun Jung;Lee, Joon Soo;Lee, Jong Doo;Kim, Heung Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.3
    • /
    • pp.286-292
    • /
    • 2008
  • Purpose : We performed EEG and PET on children with epilepsy concomitantly in order to evaluate the effects of epileptiform and non-epileptiform discharge of EEG on glucose metabolism. Methods : Seventy three children with epilepsy who had PET and EEG simultaneously were included in our study. The subjects were classified in two ways: (1) based on the frequency of epileptiform discharge and (2) the severity of non-epileptiform discharge. We evaluated the clinical aspects of their seizures, the severity of focal slow waves during the interictal period with the frequency of spikes or sharp waves in order to compare with the PET results. Results : The subjects were divided by the frequency of epileptiform discharge, with 13 in the no/rare group, 7 in the occasional group, and 53 children in the frequent group. The concordant rates with PET in each group were 0%, 42.9%, and 67.9%, respectively, showing high correlations with the frequency of epileptiform discharge (P<0.05, r=0.491). The subjects as divided by the severity of non-epileptiform discharge were 15 in the no group, 25 in the infrequent group, 17 in the intermediate group, and 16 in the continuous group. The concurrence rates with PET for each group were 13.3%, 52.0%, 64.7%, and 68.8%, respectively, also showing a high correlation with the severity of non-epileptiform discharge (P<0.05, r= 0.365). Conclusion : Epileptiform discharge and non-epileptiform discharge in EEG showed a certain association with hypometabolism in PET. We recommend EEG to reduce false lateralization and to localize lesions in cases of high frequency and severity.

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Layered Double Hydroxide Nanoparticles for Bio-Imaging Applications (LDH 나노입자 기반의 바이오 이미징 소재)

  • Jin, Wenji;Ha, Seongjin;Lee, Dongki;Park, Dae-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.445-454
    • /
    • 2019
  • Layered double hydroxides (LDHs) nanoparticles have emerged as novel nanomaterials for bio-imaging applications due to its unique layered structure, physicochemical properties, and good biocompatibility. Bio-imaging is one of the most important fields for medical applications in clinical diagnostics and therapeutics of various diseases. Enhanced diagnostic techniques are needed to realize new paradigm for next-generation personalized medicine through nanoscale materials. When nanotechnology is introduced into bio-imaging system, nanoparticle probes can endow imaging techniques with enhanced ability to obtain information about biological system at the molecular level. In this review, we summarize structural features of LDH nanoparticles with current issues of bio-imaging system. LDH nanoparticle probes are also discussed through in vitro as well as in vivo studies in various bio-imaging techniques including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and computed X-ray tomography (CT), which will have the potential in the development of the advanced nanoparticles with high sensitivity and selectivity.

The Role of F-18 Fluorodeoxyglucose Positron Emission Tomography in Patients with Malignant Mixed Mullerian Tumors of the Uterus (자궁의 악성 혼합성 뮬러리안 종양 환자에서의 FDG PET의 역할)

  • Hidayat, Basuki;Cheon, Gi-Jeong;Chae, Min-Jeong;Kim, Moon-Hong;Kim, Min-Suk;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • Purpose: Malignant Mixed Mullerian Tumor (MMMT) of the uterine corpus is one of the very uncommon and the most lethal tumors in the uterus. The aim of this study was to evaluate the role of FDG PET in detecting distant metastasis and residual and/or recurrent disease. Methods: Ten patients who underwent FDG PET for detecting distant metastasis and recurrence were included. focal FDG accumulation was regarded as abnormal. We also reviewed serum CA 125 levels, anatomical images, and histopathoiogical examination. Results: Three patients of 10 FDG PET showed abnormal FDG uptake. One had high serum CA 125 levels and high fractions of carcinomatous element on histopathologic examination. FDG PET showed metastatic lesions in unexpected locations, which could not be detected by anatomical images. Another had normal serum CA 125 levels with high sarcomatous element and CT could only detect a few lesions. The other had high serum CA 125 levels and also had high carcinomatous element. Seven patients who had no abnormal uptake on FDG PET had no clinical evidence of recurrence during the follow up period ($51.7{\pm}12.2$ months). The mean disease free intervals of these 7 patients were $36.4{\pm}6.0$ months. Two patients with abnormal findings had never become disease-free condition during the follow up period ($6.0{\pm}4.2$ months. Conclusion: FDG PET could be a useful modality for unexpected distant metastasis and follow up tool in patients with MMMT.

Diagnostic Efficacy of FDG-PET in Solitary Pulmonary Nodule (고립성폐결절에서 FDG-PET의 진단적 유용성)

  • Kim, Woo-Jin;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1263-1270
    • /
    • 1997
  • Background : Differentiation of malignity and benignity is crucial for management of solitary pulmonary nodule(SPN). Clinical parameters such as patient's age, nodule size, smoking history, doubling time, typical calcification in X-ray and CT findings have been reported as helpful in this purpose. However, in most cases, these parameters are not conclusive. Glucose metabolism is increased in cancer tissues including lung cancer tissues. After uptake of 2-[F-18]-fluoro-2-deoxy-D-glucose(FDG), the glucose analogue, by cancer cell, FDG is trapped in the cell without further metabolism after phosphorylation. Thus, hypermetabolic focus in FDG-positron emission tomography (PET) imaging suggest malignancy. We evaluated the diagnostic efficacy of FDG-PET imaging in distinguishing malignant and benign SPN. Methods : We evaluated 28 patients with SPN from Jan. 1995 to Jan. 1997. CT scan of chest and whole-body FDG-PET imaging were performed in all patients. Histologic diagnosis was confirmed by transthoracic fine needle aspiration and biopsy, bronchoscopic biopsy and open thoracotomy. Results : Of the 28 SPN's, 22 nodules were malignant and 6 nodules were benign. FDG-PET imaging diagnosed all malignant nodules correctly as positive, and diagnosed 4 of 6 benign nodules correctly as negative. One tuberculous granuloma and one aspergilloma showed hypennetabolic focus and were diagnosed falsely positve with FDG-PET imaging. In the diagnosis of SPN with FDG-PET, sensitivity and specificity were 100% and 66.7%, positive predictive value and negative predictive value were 92% and 100%. Conclusion : FDG-PET imaging is highly useful noninvasive diagnostic tool in distinguishing between malignant SPN and benign SPN.

  • PDF

Principle and Recent Advances of Neuroactivation Study (신경 활성화 연구의 원리와 최근 동향)

  • Kang, Eun-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.172-180
    • /
    • 2007
  • Among the nuclear medicine imaging methods available today, $H_2^{15}O-PET$ is most widely used by cognitive neuroscientists to examine regional brain function via the measurement of regional cerebral blood flow (rCBF). The short half-life of the radioactively labeled probe, $^{15}O$, often allows repeated measures from the same subjects in many different task conditions. $H_2^{15}O-$ PET, however, has technical limitations relative to other methods of functional neuroimaging, e.g., fMRI, including relatively poor time and spatial resolutions, and, frequently, insufficient statistical power for analysis of individual subjects. However, recent technical developments, such as the 3-D acquisition method provide relatively good image quality with a smaller radioactive dosage, which in turn results in more PET scans from each individual, thus providing sufficient statistical power for the analysis of individual subject's data. Furthermore, the noise free scanner environment $H_2^{15}O$ PET, along with discrete acquisition of data for each task condition, are important advantages of PET over other functional imaging methods regarding studying state-dependent changes in brain activity. This review presents both the limitations and advantages of $^{15}O-PET$, and outlines the design of efficient PET protocols, using examples of recent PET studies both in the normal healthy population, and in the clinical population.

Utility of FDG-PET in Solitary Pulmonary Nodules and the Relationship Between Standardized Uptake Values of PET and Serum Glucose (폐 결절에서 FDG-PET의 유용성과 표준섭취계수와 혈당농도의 상관관계)

  • Kim, Kyu Sik;Lim, Sung Chul;Ko, Young Chun;Park, Kyung Ha;Ju, Jin Young;Jo, Kae Jung;Kim, Soo Ok;Oh, In Jae;Kim, Yu Il;Kim, Young Chul;Kim, Sung Min;Song, Ho Chun;Bom, Hee Seung;Park, Kyung Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.589-596
    • /
    • 2003
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patients in the our nation with high incidence of tuberculoma. We could not exclude whether the SPN was benign or malignant by the change of the size at chest radiograph and findings of chest CT. Recently, positron emission tomography(PET) have been tried as the differential diagnostic method of SPN. We evaluated the efficacy of PET for differentiating malignant from benign SPN and the relationship between standardized uptake values(SUV) of PET and serum glucose. Method : Between January 2001 and July 2002, sixty-one patients with pulmonary nodule were examined by the chest CT and PET. The SPN has been finally diagnosed by the transthorasic needle aspiration and biopsy, bronchoscopic biopsy, and open lung biopsy. Results : Forty eight patients had a malignant nodule(23 squamous cell lung carcinoma, 16 adenocarcinoma, 9 small cell lung cancer) and thirteen patients had a benign nodule(3 tuberculoma, 9 inflammatory granuloma, 1 cryptococcosis). The mean size of malignant and benign nodule was 40.6 mm and 20.0 mm, respectively. All malignant nodules showed a marked increase in 18 fluorodeoxyglucose (FDG) uptake. Mean SUV of malignant was $9.52{\pm}5.20$ and benign nodule was $1.61{\pm}3.60$. There were false positive cases with an increase in 18-FDG uptake (2 tuberculoma, 1 inflammatory granuloma). The SUV of malignant nodule in diabetes patients has no difference in non diabetes patients($9.10{\pm}4.51$ vs $9.65{\pm}5.46$). The sensitivity and specificity of the PET scan for SPN were 100%, 77%, respectively. The positive and negative predictive values were 94% and 100%. Conclusion : PET scanning showed highly accurate result in differentiating the malignant and benign SPN. There were no significant differences between the SUV and serum glucose in the patients with lung cancer.

An Assessment of the Accuracy of 3 Dimensional Acquisition in F-18 fluorodeoxyglucose Brain PET Imaging (3차원 데이터획득 뇌 FDG-PET의 정확도 평가)

  • Lee, Jeong-Rim;Choi, Yong;Kim, Sang-Eun;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.327-336
    • /
    • 1999
  • Purpose: To assess the quantitative accuracy and the clinical utility of 3D volumetric PET imaging with FDG in brain studies, 24 patients with various neurological disorders were studied. Materials and Methods: Each patient was injected with 370 MBq of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose. After a 30 min uptake period, the patients were imaged for 30 min in 2 dimensional acquisition (2D) and subsequently for 10 min in 3 dimensional acquisition imaging (3D) using a GE $Advance^{TM}$ PET system, The scatter corrected 3D (3D SC) and non scatter-corrected 3D images were compared with 2D images by applying ROIs on gray and white matter, lesion and contralateral normal areas. Measured and calculated attenuation correction methods for emission images were compared to get the maximum advantage of high sensitivity of 3D acquisition. Results: When normalized to the contrast of 2D images, the contrasts of gray to white matter were $0.75{\pm}0.13$ (3D) and $0.95{\pm}0.12$ (3D SC). The contrasts of normal area to lesion were $0.83{\pm}0.05$ (3D) and $0.96{\pm}0.05$ (3D SC). Three nuclear medicine physicians judged 3D SC images to be superior to the 2D with regards to resolution and noise. Regional counts of calculated attenuation correction was not significantly different to that of measured attenuation correction. Conclusion: 3D PET images with the scatter correction in FDG brain studies provide quantitatively and qualitatively similar images to 2D and can be utilized in a routine clinical setting to reduce scanning time and patient motion artifacts.

  • PDF