• 제목/요약/키워드: Positive sequence

검색결과 871건 처리시간 0.025초

Cloning and Sequence Analysis of a Levansucrase Gene from Rahnella aquatilis ATCC15552

  • Kim, Hyun-Jin;Yang, Ji-Young;Lee, Hyeon-Gye;Cha, Jae-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권4호
    • /
    • pp.693-699
    • /
    • 2001
  • An intracellular levansucrase gene, lscR from Rahnella aquatilis ATCC 15552, was cloned and its nucleotide sequence was determined. Nucleotide sequence analysis of this gene revealed a 1,238 bp open reading frame coding for a protein of 415 amino acids. The levansucrase was expressed by using a T7 promoter in Escherichia coli BL21 (DE3) and the enzyme activity was detected in the cytoplasmic fraction. The optimum pH and temperature of this enzyme for levan formation was pH 6 and $30^{\circ}C$, respectively. The deduced amino acid sequence of the lscR gene showed a high sequence similarity (59-89%) with Gram-negative levansucrses, while the level of similarity with Gram-positive enzymes was less than 42%. Multiple alignments of levansucrase sequences reported from Gram-negative and Gram-positive bacteria revealed seven conserved regions. A comparison of the catalytic properties and deduced amino acid sequence of lscR with those of other bacterial levansucrases strongly suggest that Gram-negative and Gram-positive levansucrases have an overall different structure, but they have a similar structure at the active site.

  • PDF

A Study on DVR Control for Unbalanced Voltage Compensation

  • Jung Hong-Ju;Suh In-Young;Kim Byung-Seob;Kim Rae-Young;Choi See-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.803-807
    • /
    • 2001
  • This paper presents a new control scheme for a DVR (Dynamic Voltage Restorer) system consisting of series voltage source PWM converters. To control the negative sequence components of the source, it is necessary to detect the negative sequence components. Generally, a filtering process is used which has some undesirable effects. This paper suggests a new method for separating positive and negative sequences components. This control system is designed using differential controllers and digital filters. The positive and negative sequences are extracted and controlled individually. The performance of the presented controller and scheme are confirmed through simulation and actual experiment with a 2.5kVA prototype DVR system.

  • PDF

비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어 (Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter)

  • 이해춘;박태열;김기택
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

정상 성분 변화량을 이용한 송전선로 보호용 방향 계전 알고리즘 (A Directional Relay Algorithm Using Positive-Sequence Superimposed Quantity for Transmission Line Protection)

  • 이명수;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.226-233
    • /
    • 2003
  • Directional elements are fundamental to protection scheme security and selectivity, performing such critical tasks as supervising distance elements and controlling overcurrent elements. But, conventional operating principles for directional detection based on negative or zero sequence quantify do not satisfy the requirements for improved sensitivity and fast operation under any fault conditions. In this paper, new algorithm for directional elements is proposed. The proposed algorithm use the positive-sequence superimposed voltages and currents in order to be used in all fault conditions. Also, because this algorithm uses a voltage compensation method. it can be well operated under strong source conditions.

실계통 345kV 지중송전선 대칭좌표 임피던스의 해석 (Analysis of Sequence Impedances of 345kV Cable Transmission Systems)

  • 최종기;안용호;윤용범;오세일;곽양호;이명희
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

REPRESENTING NATURAL NUMBERS AS UNIQUE SUMS OF POSITIVE INTEGERS

  • Laohakosol, Vichian;Chalermchai, Jiraporn
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제11권1호
    • /
    • pp.63-72
    • /
    • 2004
  • It is known that each natural number can be written uniquely as a sum of Fibonacci numbers with suitably increasing indices. In 1960, Daykin showed that the sequence of Fibonacci numbers is the only sequence with this property. Consider here the problem of representing each natural number uniquely as a sum of positive integers taken from certain sequence allowing a fixed number, $\cal{l}\geq2$, of repetitions. It is shown that the $(\cal{l}+1)$-adic expansion is the only such representation possible.

  • PDF

CONSISTENCY AND GENERAL TRUNCATED MOMENT PROBLEMS

  • Yoo, Seonguk
    • 충청수학회지
    • /
    • 제31권4호
    • /
    • pp.487-509
    • /
    • 2018
  • The Truncated Moment Problem (TMP) entails finding a positive Borel measure to represent all moments in a finite sequence as an integral; once the sequence admits one or more such measures, it is known that at least one of the measures must be finitely atomic with positive densities (equivalently, a linear combination of Dirac point masses with positive coefficients). On the contrary, there are more general moment problems for which we aim to find a "signed" measure to represent a sequence; that is, the measure may have some negative densities. This type of problem is referred to as the General Truncated Moment Problem (GTMP). The Jordan Decomposition Theorem states that any (signed) measure can be written as a difference of two positive measures, and hence, in the view of this theorem, we are able to apply results for TMP to study GTMP. In this note we observe differences between TMP and GTMP; for example, we cannot have an analogous to the Flat Extension Theorem for GTMP. We then present concrete solutions to lower-degree problems.

A COMPLETENESS ON GENERALIZED FIBONACCI SEQUENCES

  • Lee, Gwang-Yeon
    • 대한수학회보
    • /
    • 제32권2호
    • /
    • pp.239-249
    • /
    • 1995
  • Let $V = (v_1, v_2, \cdots)$ be a sequence of positive integers arranged in nondecreasing order. We define V to be complete if every positive integer n is the sum of some subsequence of V, that is, $$ (1.1) n = \sum_{i=1}^{\infty} a_i v_i where a_i = 0 or 1.

  • PDF

지중송전선로의 대칭분 임피던스 모델링에 관한 연구 (A Study on the Sequence Impedance Modeling of Underground Transmission Systems)

  • 황영록;김경철
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.