• Title/Summary/Keyword: Positive Corona

Search Result 123, Processing Time 0.029 seconds

Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature (온도변화에 따른 $SF_6$ 가스의 절연특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Lee, Kyu-Sun;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF

Ionic Wind Generation Characteristics of a Water-Pen Point-to-Mesh Type Discharge System (수침대 그물전극형 방전장치의 이온풍 발생특성)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.783-787
    • /
    • 2009
  • A point-to-mesh type discharge system, utilizing a water-pen point as a corona discharge electrode and a mesh as an ion induction electrode, has been proposed, and the effect of the water-pen point electrode of the discharge system to the ionic wind velocity and generation yield was investigated. It was observed that the proposed discharge system with the water-pen point electrode can generate a higher ionic wind velocity as compared with that of the metal point electrode. As a result, the peak ionic wind velocities of 2.61 and 4.05 m/s for the positive and negative corona discharges of the proposed discharge system can be obtained, which are 1.39 and 1.15 times higher than those of the metal point electrode with same design. The ionic wind generation yield of 4.72 m/s/W of the discharge system with the water-pen point electrode was obtained for the positive corona, which was 3.66 times higher than that of the metal point electrode. This enhancement may be due to the effect of the water-pen point electrode.

Synthesis and Absorption Spectra of 1,4-Diketo-3,6-Diphenyl-Pyrrolo-[3,4c]-Pyrrole (1,4-Diketo-3,6-Diphenyl-Pyrrolo-[3,4c]-Pyrrole(DPP)계 유기안료의 합성 및 흡수스펙트라)

  • 김성훈
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.1-15
    • /
    • 1996
  • In this paper, the preparation of lead zirconium titanate(PZT) thin film by sol-gel processing was descried. Thin film coated with thickness of 4${\mu}{\textrm}{m}$ on the stainless steel substrates using the multiple spin-coating process. The crystalline phases of PZT powder and film were investigated by X-ray diffraction pattern and PZT thin film has perovskite structure over 600 C annealing temperature. Corona charging characteristics of the ferroelectric PZT thin film at 600 C were investigated by electrophotographic measurement. A difference in the charging characteristics between positive and negative corona charging was found. The charge acceptance depended in the polarity of corona and the poling of film. According to the D-E hysteresis measurment, PZT thin film can be poled by corona charging without use of top electrode. The remnant polarization in the PZT thin film is generally in the order of 48$\mu$C/$\textrm{cm}^2$. From this results, the ferroelectric PZT thin film will be possible to apply for the add-on type imaging formation.

  • PDF

Chartacteristic of Ozone Genneration by corona Discharge (코로나 방전에 의한 오존 생성 특성)

  • Jeun, Young-Ju;Kang, Chun-Su;Park, Won-Ju;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1375-1377
    • /
    • 1995
  • This paper describes characteristic of ozone Generation by positive streamer corona discharge. Experiments were carried out with needle-plane Electrodes in a pyrex glass tube, in order to in crease the ozone yield. The results of Experiments confirmed needle an gle $45^{\circ}$ Gap spacing 15mm is adaptive Electrode arrangement.

  • PDF

A Study on the Development of an Electrostatic Eliminator and Evaluating Method of Explosion-Protection Construction (방폭형 제전기의 개발 및 평가방법에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.49-54
    • /
    • 2014
  • Electrostatic eliminators are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, and ultraviolet and glow discharge. Among them, corona discharge is generally used, because the corona discharge can easily and economically produce positive and negative ions including electrons in air at atmospheric pressure. But it is necessary to equip explosion-protection electrostatic eliminators wherever hazardous atmosphere. The electrostatic eliminators and their testing method of explosion-protection type have been developed in this research. The contents and scope of the research as follows; developing the type 'Ex s IIB T4' electrostatic eliminator of explosion-protection; developing the type 'Ex s d IIB T4' electrostatic eliminator of explosion-protection; developing the explosion-protection performance testing method of electrostatic eliminator for using AC power source.

Ozone Generation by Superimposing Discharge Reactor (중첩방전 반응기에 의한 오존의 생성)

  • ;;;;;M. Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.63-68
    • /
    • 1999
  • In this paper, characteristics of ozone generation by using coil and SPCP + DC corona reactor was studied. The ceramic-based surface discharge electrode, which was first invented as a high-efficiency ozonizer, has been used as an experimental plasma chemical reactor.(Surface Induced Plasma Chemical Processing, SPCP.) The electrode, however, has a structural disadvantage that a highly energetic plasma region is localized near the electrode surface, which may make it impossible for higher efficiency to realize. In an attempt to overcome this advantage, we have developed a hybrid reactor which employs a corona discharge unit together with the surface discharge unit. Experimental results suggest that the efficiency of the ozone production rate is improved when positive corona discharge is added.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

Decomposition of Odorous Gases in a Pilot-scale Nonthermal Plasma Reactor

  • Hwang, Yoon-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.57-65
    • /
    • 2005
  • An experimental study was performed on the decomposition of gaseous ammonia and two selected volatile organic compounds (VOCs: toluene and acetone) in a combined nonthermal plasma reactor with corona and glow discharges. A lab pilot scale reactor (206 liter) equipped with a high electric power pack was used to determine the decomposition efficiency in relation with the inlet concentration and applied voltage. Three different types of discharging electrode such as wired rack, wire strings for corona discharge, and thin plate for glow discharge were put in order in the reactor. While decomposition of ammonia decreased with an increase in the initial concentration, acetone showed an opposite result. In the case of toluene however no explicit tendency was found in toluene and aceton. Negative discharge resulted in high decomposition efficiency than the positive one for all gases. A better removal of gas phase element could be achieved when fume dust were present simultaneously.

The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures ($SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성)

  • Lee, B.H,;Kim, J.I.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

Prebreakdown Corona Processes of Point-to-Plane Gap in $SF_{6}$ Gas ($SF_{6}$ 가스중에서 침-평판가극의 전구코로나과정)

  • 이복희;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.140-143
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_{6}$ gas and prebreakdown growth caused by lightning impulse voltages in inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is obserbed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrustion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields ad partial discharges in voids.

  • PDF