• Title/Summary/Keyword: Positive Corona

Search Result 123, Processing Time 0.032 seconds

Simulation of Charging Process in PTFE Electret (PTFE 일렉트렛트의 대전 과정 시뮬레이션)

  • Park, Geon-Ho;Kim, Sang-Jin;Sung, Nak-Jin;Bae, Duk-Kwun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.123-126
    • /
    • 2005
  • In this study, the Thermally Stimulated Current(TSC) of corona charged PTFE is studied and the simulation of corona charging process is also calculated by Finite Element Method. The electrets which were formed by applying high voltages (DC ${\pm}5{\sim}{\pm}8$ [kV]) to PTFE, are used to measure TSC in the temperature range of $-100{\sim}+200$ [$^{\circ}C$] and then the Finite Element Method is performed to examine corona charging process using a obtained physical constants. As a result. it is confirmed that the charging negative corona is profitable as the applications are manufactured, because the time constant of negative corona is much larger than it of positive corona. And it is attempted to estimate the corona charging process in space using simulation.

  • PDF

Characteristics of Ozone Generation by Diameter and Polarity Variation of Corona Wire Electrode (코로나 선전극의 직경과 극성변화에 따른 오존발생특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.85-90
    • /
    • 2012
  • In this paper, it was investigated experimentally that diameter and polarity variation of corona wire electrode affected to ozone generation of the ozone generator using a wire-to-plate type electrode. The change in the diameter(D) of the corona wire electrode has a great effect upon ozone generation, higher influence appears in the positive corona discharge than the negative corona discharge. In the case of D=0.50[mm], maximum ozone generation and power efficiency could be obtained. However, in the case of smaller D than this, the ozone generation and efficiency decreases slowly and in the case of larger D, the ozone generation decreases rapidly. It means performance decline as an ozone generator. Therefore, ozone generation and power efficiency would increase through simple optimization of the corona electrode specification.

The Simulation of Corona Charging Process in Polytetrafluoroethylene Electret using Finite Element Method (유한요소법을 이용한 PTFE 일렉트렛트의 코로나 대전 과정 시뮬레이션)

  • 이수길;유재웅;박건호;김충혁;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.94-98
    • /
    • 1994
  • In this study, the thermally stimulated current(TSC) of corona charged PTFE film was studied and the simulation of corona charging process was also calculated by finite element method. The electrets which were formed by appling high voltages(DC-5∼-8[kV]) to PTFE film were experimented to measure TSC in the temperature range of -100∼+200 [$^{\circ}C$] and then the finite element method was accomplished to examine corona charging process using a obtained physical constants. It is confirmed that the charging negative corona is profitable as the applications are manufactured because the time constant of negative corona is much larger than it of positive corona. And it is attempted to estimate the corona charging process in space using simulation.

  • PDF

Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures (SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성)

  • Lee, Bok-Hee;Baek, Young-Hwan;Oh, Sung-Kyun;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.85-90
    • /
    • 2006
  • This paper presents experimental results relating to the preliminary breakdown characteristics in $SF_6/CO_2$ gas mixtures under a highly non-uniform electric field. The impulse pre-breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both the positive and negative polarities were fundamentally same. The first streamer corona was initiated at the tip of needle electrode, and the leaders developed with a stepwise propagation and bridged the test gap. The pause time of leader pulses in the positive polarity was significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity. The discharge channel path in the positive polarity was zigzag, and the leader channel in the negative polarity was thicker and brighter than that in the positive polarity.

Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap (다공성 수침-평판전극간의 수적 방출 특성)

  • Jung, Jae-Seung;Lee, Woo-Seok;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier (직류 코로나 하전된 강유전체구 층의 연면방전특성)

  • Geum, Sang-Taek;Lee, Geun-Taek;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF

Discharge Characteristics from a Water-Penpoint-to - Insulator-Paper-Covered-Plate Airgap (수성(水性)펜침(針) 대(對) 절연지부착평판간(絶緣紙附着平板間)의 방전특성(放電特性))

  • Moon, Jae-Duk;Lee, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1586-1588
    • /
    • 1994
  • Some interesting corona characteristics of a airgap of penpoint-to-plate with a tracing insulator paper has been investigated in a temperature and humidity controlled metal chamber. It is found that the positive and the negative carriers in the plasma region could be understood from the waterdrop traces on the paper, which indicate the bombardment by the one of electron or positive gas particle from the plasma region of near the point. It is also found that a corona discharge could be used as a means of a humidifying, since the discharge makes dispersion of watersprays from the penpoint. And the negative corona was more effective for waterspray dispersion than the positive ones.

  • PDF

A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor - (이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 -)

  • ;Mizuki Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

The effect of magnet fields on the corona discharge (코로나 방전에 대한 자계의 영향)

  • 박재윤;정장근;김익균
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2001
  • In this paper, the effect of magnetic field on corona discharge phenomena was experimentally investigated in the needle-plate electrode geometry. Needle-plate geometry discharge system with magnetic field at a right angle to the electric field was made. The corona discharge characteristics with magnetic field were investigated and compared with the corona characteristics without magnetic field in atmospheric pressure. As a result, in case of positive DC corona discharge with magnetic field, corona discharge zone was significantly wider, corona current was lower, and breakdown voltage was higher than those without magnetic field. However, in case of negative DC corona discharge with magnetic field, corona current was slightly higher and breakdown voltage was lower than those without magnetic field. It is thought that this result is due to cyclotron motion of charged particles such as electron and ion by magnetic field.

  • PDF

Ultrasonic Signal Characteristics of Corona Discharges in Air (공기중 코로나방전의 초음파신호 특성)

  • Lee, Sang-Woo;Kim, In-Sik;Lee, Kwang-Sik;Lee, Dong-In;Lee, Dong-Heoon;Bae, Sang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF