• Title/Summary/Keyword: Position sensor

Search Result 2,301, Processing Time 0.029 seconds

The Load Estimation Algorithm of the Drum Washing Machine using an Inertia Estimator (관성 추정기를 이용한 드럼 세탁기의 부하추정 알고리즘)

  • Hwang, Chun-Hwan;Lee, Jung-Hyo;Kim, Kyung-Min;Lee, Won-Cheol;Kim, Young-Real;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.150-159
    • /
    • 2009
  • Generally, the operating efficiency of the washing machine is mostly affected by the washing time. The washing time is determined by the amount and the type of the laundry. Although the type of the laundry is easily inputted by the user, but the amount of the laundry is difficult to do. For this reason, the specific process is existed for the estimation of the laundry and the time of the washing mode is determined by the estimated laundry. Therefore, this paper proposes the washing load estimation algorithm by the inertia estimator. The proposed algorithm is implemented on the PMSM drive using the low cost position sensor for practical washing machine application. The proposed algorithm is verified by the drum washing machine for the practical load condition test.

Outdoor Localization for Returning of Quad-rotor using Cell Divide Algorithm and Extended Kalman Filter (셀 분할 알고리즘과 확장 칼만 필터를 이용한 쿼드로터 복귀 실외 위치 추정)

  • Kim, Ki-Jung;Kim, Yoon-Ki;Choi, Seung-Hwan;Lee, Jang-Myung
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.440-445
    • /
    • 2013
  • This paper proposes a local estimation system which combines Cell Divide Algorithm with low-cost GPS/INS fused by Extended Kalman Filter(EKF) for localization of Quad-rotor when it returns to the departure point. In the research, the low-cost GPS and INS are fused by EKF to reduce the local error of low-cost GPS and the accumulative error of INS due to continuous integration of sensor error values. When the Quad-rotor returns to the departure point in the fastest path, a moving path can be known because it moves straight, where Cell Divide Algorithm is used to divide moving route into the cells. Then it determines the closest position of data of GPS/INS system fused by EKF to obtain the improved local data. The proposed system was verified through comparing experimental localization results obtained by using GPS, GPS/INS and GPS/INS with Cell Divide Algorithm respectively.

A Moving Target Tracking Algorithmfor a Mobile Robot Based on a 2D Image of a Line Light (직선광선의 2D 영상을 이용한 이동로봇의 이동물체 추적 알고리즘)

  • Rim, Ho;Hahn, Hernsoo;Hong, Min-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.11-21
    • /
    • 2000
  • This paper proposes a new algorithm for a mobile robot that detects and tracks a moving target, keeping it in the view range of the robot. The sensor system consists of a camera and a line light source. The camera system is placed so that the line light projected into the ground from the light source forms its image along the horizontal center line of the CCD array of the camera. The deformation of the line image from the horizontal center line contains the information on existence of a moving object, its velocity, and position. Since the proposed algorithm reduces the region of the image to be searched, it reduces the computational complexity significantly comparing to the conventional image processing algorithms. The performance of the proposed algorithm has been tested by implementing on a mobile robot.

  • PDF

Comparison of Upper and Lower Cervical Muscle Strengths Between Subjects With and Without Forward Head Posture

  • Eun, Ji-yeon;Kwon, Oh-yun;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.272-277
    • /
    • 2020
  • Background: Forward head posture (FHP) is common postural malalignment. FHP is described relatively extension to upper cervical and lower cervical is relatively flexion. Although several researchers mentioned the lower cervical flexion posture in FHP, most of the studies related to FHP is focused on the deep cervical flexor function. Objects: The purposes of present study is to compare the cervical strength (upper cervical extension [UCE], lower cervical extension [LCE], upper cervical flexion [UCF], lower cervical flexion [LCF]) between individuals with and without FHP. Methods: Fifty-one participants are recruited. Participants who have the craniovertebral angle (CVA) less than 48 degree were classified to the FHP group (n = 24) and the others were included in without FHP group (n = 27). The cervical strength (UCE, LCE, UCF, LCF) were measured using Smart KEMA strength sensor and the strength data was normalized by body weight. All strength measurement conducted at head and neck neutral position in sitting. Independent t-test was used to compare the cervical strength between individuals with and without FHP. Results: The mean value of CVA was greater in without FHP group than with FHP group (p < 0.000). The strength value of UCF (p < 0.002) and LCE (p < 0.001) was significant less in FHP group than without FHP group. But no significant differences were seen in the LCF and UCE strength between two groups. Conclusion: UCF and LCE weakness in FHP group should be considered to evaluate and manage the individuals with FHP.

Relationship Between Strength of Hip Muscles and Performance of Close Kinetic Chain Dynamic Lower Extremity Stability Test

  • Lee, Hyeon-ju;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.257-263
    • /
    • 2020
  • Background: The hip muscle plays various roles. Several types of functional performance tests are used for the assessment of patients with various lower extremity injuries. Hip muscle functions are important to test the performance of maintaining the spine, pelvic, and leg during bridging exercise. We designed a novel functional performance test tool, which we named close kinetic chain dynamic lower extremity stability (CKCLE) test to assess hip muscle functions. Objects: The purpose of this study was to determine the relationship between CKCLE test and hip extensor, external rotator, and abductor strengths. Methods: Twenty-two subjects were recruited in the present study (13 males and 9 females). The hip extensor, external rotator, and abductor muscle strengths were measured using a Smart KEMA strength sensor. When the examiner said "Go", the subject performed the CKCLE test by moving one leg from the floor and touching the opposite knee and then return to the floor while maintaining the bridging position. The subjects attempted as many "touches" as possible in the allotted time (20 seconds) during the maximal tests. The correlation between the hip muscle (extensor, external rotator, and abductor) strength of the supporting leg and the number of CKCLE tests performed in 20 seconds was determined using the Pearson correlation. Results: Hip extensor (r = 0.626, p < 0.05), hip external rotator (r = 0.616, p < 0.05), and hip abductor muscle strengths (r = 0.475, p < 0.05) positively correlated with the number of CKCLE tests performed. Conclusion: We designed a CKCLE test and found that performance in the test correlated with hip extensor, external rotator, and abductor muscle strengths. The result suggests that the CKCLE test can be applied as a performance test to assess the functions of the hip extensor, external rotator, and hip abductor muscles.

Development of application for guidance and controller unit for low cost and small UAV missile based on smartphone (스마트폰을 활용한 소형 저가 유도탄 유도조종장치용 어플리케이션 개발)

  • Noh, Junghoon;Cho, Kyongkuk;Kim, Seongjun;Kim, Wonsop;Jeong, Jinseob;Sang, Jinwoo;Park, Chung-Woon;Gong, Minsik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.610-617
    • /
    • 2017
  • In the recent weapon system trend, it is required to develop small and low cost guidance missile to track and strike the enemy target effectively. Controling the such small drone typed weapon demands a integrated electronic device that equipped with not only a wireless network interface, a high resolution camera, various sensors for target tracking, and position and attitude control but also a high performance processor that integrates and processes those sensor outputs in real-time. In this paper, we propose the android smartphone as a solution for that and implement the guidance and control application of the missile. Furthermore, the performance of the implemented guidance and control application is analyzed through the simulation.

Development of Error Compensation System and On the Machine Measurement System for Ultra-Precision Machine (초정밀가공기용 오차보상시스템 및 기상측정장치 개발)

  • 이대희;나혁민;오창진;김호상;민흥기;김민기;임경진;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.599-603
    • /
    • 2003
  • This paper present an error compensation system and On-Machine Measurement(OMM) system for improving the machining accuracy of ultra-precision lathe. The Fast-Tool-Servo(FTS) driven by a piezoelectric actuator is applied for error compensation system. The controller is implemented on the 32bit DSP for feedback control of piezoelectric actuator. The control system is designed to compensates three kinds of machining errors such as the straightness error of X-axis slide, the thermal growth error of the spindle. and the squareness between spindle and X-axis slide. OMM is preposed to measure the finished profile of workpiece on the machine-tool using capacitive sensor with highly accurate ruby tip probe guided by air bearing. The data acquisition system is linked to the CNC controller to get the position of each axis in real-time. Through the experiments, it is founded that the thermal growth of spindle and tile squareness error between spindle and X-axis slide influenced to machining error more than straightness error of X-axis slide in small travel length. These errors were simulated as a sinusoidal signal which has very low frequency and the FTS could compensate the signal less than 30 m. The implemented OMM system has been tested by measuring flat surface of 50 mm diameter and shows measurement error less than 400 mm

  • PDF

Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera (CCD 카메라를 이용한 열화상 실시간 추정과 화재경보)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.92-98
    • /
    • 2016
  • This study evaluated thermal image real-time estimation and fire alarm using by a CCD camera, which has been a seamless feature-point analysis method, according to the angle and position and image fusion by a vector coordinate point set-up of equal shape. The system has higher accuracy, fixing data value of temperature sensing and fire image of 0~255, and sensor output-value of 0~5,000. The operation time of a flame specimen within 500 m, 1000 m, and 1500 m from the test report specimen took 7 s, 26 s, and 62 s, respectively, and image creation was proven. A diagnosis of fire accident was designated to 3 steps: Caution/Alarm/Fire. Therefore, a series of process and the transmission of SNS were identified. A light bulb and fluorescent bulb were also tested for a false alarm test, but no false alarm occurred. The possibility that an unwanted alarm will be reduced was verified through a forecast of the fire progress or real-time estimation of a thermal image by the change in the image of a time-based flame and an analysis of the diffusion velocity.

A Study on the Design and Performance of Integrated-Optic Biosensor utilizing the Multimode Interferometer based on Si3N4 Rib-Optical Waveguide and Evanescent-Wave (Si3N4 립-광도파로 기반 다중모드 간섭기와 소산파를 이용하는 집적광학 바이오센서 설계 및 성능에 관한 연구)

  • Jung, Hong sik
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.409-418
    • /
    • 2020
  • In this paper, an integrated optical, evanescent-wave biosensor utilizing a multimode interferometer based on a Si3N4 rib-optical waveguide consisting of the Si/SiO2/Si3N4/SiO2 stacked structure was described. The theoretical background of the multimode interferometer was reviewed, and the structure and design process were presented through numerical computational analysis. We analyzed how the dimension (length, width) of the multimode interferometer affected the sensor performance. It has been confirmed through computational analysis that the changes in the refractive index of an analyte greatly affect the mode pattern formation position and output optical power of a multimode interferometer, and proved that this principle could be applied to integrated-optic biosensor.

Position and Attitude Estimation of a Capsule Endoscope based on Ultrasonic Ranging (초음파 거리를 이용한 캡슐 내시경의 위치 및 자세각 추정)

  • Kim, Eun-Joung;Kim, Myung-Yu;Kim, Deok-Ki;Kim, Yong-Dae;You, Young-Gap
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.38-44
    • /
    • 2007
  • This paper presented a location and attitude estimation scheme of a capsule endoscope based on ultrasonic ranging. The scheme comprised eight on-capsule ultrasonic sensors to alleviate measurement errors due to irregularities in human body ultrasonic characteristics. It calculated the coordinate values and angles in a Cartesian coordinate system. The Matlab simulation reflecting random errors yielded the average deviations of 0.8mm in the location and $0.2^{\circ}$ in the attitude angle. These values are far smaller than normal intestine movement ranges inside human body, and will contribute accurate diagnosis of intestine.