• 제목/요약/키워드: Position sensitive detector

검색결과 99건 처리시간 0.024초

관절각 측정을 위한 적외선 각도 센서 연구 (Design of Infrared Angular Sensor for Human Joint Angle)

  • 오한별;김지선;김아희;고봉준;김준식;이은숙;최주현;전재훈
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.792-798
    • /
    • 2015
  • Joint angle generally can be measured to check the recovery process in rehabilitation field. This paper suggests to measure joint angle with Infrared sensor based on triangulation principle. We performed various experiments to find the optimal condition of the sensor’s attached distance, height, and angle. The results were compared with commercial goniometer for accuracy. The proposed infrared joint angle sensor can be effectively used in rehabilitation and sport science fields.

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측 (Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring)

  • 김영수;박진형;조화연;김재현;권흥록;서희;박세환;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 콤프턴 카메라는 검출 신호의 동시성 판단을 기반으로 한 전자적 집속방식을 이용하기 때문에, 기존의 물리적 집속기를 이용하는 감마선 영상 장비의 가시영역이 좁고 투과력이 높은 고에너지 감마선에 적용하기 어렵다는 한계를 극복할 수 있다. 특히 대면적의 콤프턴 카메라는 절대 검출 효율이 높아 영상 장비의 운반이 요구되지 않는 대규모 공정 시설내 핵물질의 모니터링용으로 매우 적합하다. 본 연구팀은 한국원자력연구원에서 개발 중인 파이로 시험 공정 시설에서의 안전조치 수립을 위해 대면적 콤프턴 카메라를 적용하고자 한다. 대면적 콤프턴 카메라를 구성하는 대면적의 검출기는 그 형태나 구성 방식에 따라 에너지 분해능이나 위치 분해능이 달라질 수 있다. 이는 콤프턴 영상의 질에 직접적으로 영향을 미치므로, 본 연구에서는 전산모사를 통해 그 영향을 예측하여 대면적 검출기의 설계 방향을 결정하였다. 또한 한국원자력연구원으로부터 파이로 시험 공정 시설의 정보를 전달받아 전산모사를 수행하였고, 여러 계측 환경에 대해 대면적 콤프턴 카메라의 성능을 예측하여 보았다. 그 결과 대면적 검출기는 에너지 분해능 측면에서의 손실을 최소화 할 수 있도록 구성하여야 한다는 결론을 얻었으며, 에너지 분해능 10%, 위치 분해능 7 mm 정도 성능의 검출기를 이용하여 콤프턴 카메라를 구성할 경우 1 m 거리에 위치한 감손우라늄 선원을 영상 해상도 16.3 cm(각도 분해능 $9.26^{\circ}$)으로 영상화할 수 있음을 확인하였다.

자연치열에 설치한 pivot의 전후방 일치변화에 따른 하악의 moment에 관한 연구 (A STUDY ON THE MANDIBULAR MOMENTS ACCORDING TO ANTERO-POSTERIOR PLACEMENT OF PIVOT ON LOWER NATURAL DENTITION)

  • 이현식;박남수;최대균
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.394-410
    • /
    • 1993
  • This study was accomplished for appreciation of the mandibular moments according to antero- posterior movement of pivot placed on the lower natural dentition. For this study, 20 subjects(male, $21\sim30$ yrs., average age 24) in the category of normal occlusion were selected, and the intraoral Vitallium clutches were cast and fabricated for each subjects. A 2-dimension PSD(Position Sensitive Detector, Hamamatsu Photonics Co., Japan) was attached to maxillary clutch in a mode of three dimensional control and LED (Light Emit Diode, Hamamatsu Photonics Co., Japan) was set up on mandibular clutch. Both clutches were set into oral cavity of each subjects and adjusted. Then the subjects were allowed to intercuspated with maximal bite force while the pivoting ball in the mid-line moving from anterior toward posterior position. The displacement scales were recorded by CCD camera(Sony, CCD-TR-705) and VCR, The conclusions were as follows : 1. When the subject was allowed to bite the metal pivoting ball in the midline of lower dentition with maximal bite force voluntarily while moving from lower central incisor to canine, 1st premolar, End premolar, 1st molar and 2nd molar. The lever actions on the pivot were revealed in all subjects. The equilibrium of moment were revealed on the pivots of 1st premolar(14 subjects), End premolar(4 subjects), and canine(2 subjects) areas. 2. The changes of loading on the TMJ according to antero-posterior positional changes of metal pivoting ball were able to recognize as follow. Compression on the TMJ was increased when the pivot moves anteriorly from the equilibrium point, and tension on the TMJ was increased when posteriorly. 3. 13 subjects were recognized their habitual chewing sides(Rights, Left8), and 7 subjects were not. During maximal biting, mandible was displaced toward their habitual chewing sides on the metal pivoting ball in the frontal plane. 4. In cephalometric analysis, the average genial angle of 20 subjects was $116.75^{\circ}$ and the average mandibular body length was 79.77mm. The equilibrium points of mandibular moment were positioned more posteriorly in the subjects having larger Genial angle than in the smaller(p<0.05). Relationships among the angle between FH plane and occlusal plane, the angle between occlusal plane and mandibular plane , and mandibular body length were not significant(p>0.05).

  • PDF

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

AAM 기반 얼굴 표정 인식을 위한 입술 특징점 검출 성능 향상 연구 (A Study on Enhancing the Performance of Detecting Lip Feature Points for Facial Expression Recognition Based on AAM)

  • 한은정;강병준;박강령
    • 정보처리학회논문지B
    • /
    • 제16B권4호
    • /
    • pp.299-308
    • /
    • 2009
  • AAM(Active Appearance Model)은 PCA(Principal Component Analysis)를 기반으로 객체의 형태(shape)와 질감(texture) 정보에 대한 통계적 모델을 통해 얼굴의 특징점을 검출하는 알고리즘으로 얼굴인식, 얼굴 모델링, 표정인식과 같은 응용에 널리 사용되고 있다. 하지만, AAM알고리즘은 초기 값에 민감하고 입력영상이 학습 데이터 영상과의 차이가 클 경우에는 검출 에러가 증가되는 문제가 있다. 특히, 입을 다문 입력얼굴 영상의 경우에는 비교적 높은 검출 정확도를 나타내지만, 사용자의 표정에 따라 입을 벌리거나 입의 모양이 변형된 얼굴 입력 영상의 경우에는 입술에 대한 검출 오류가 매우 증가되는 문제점이 있다. 이러한 문제점을 해결하기 위해 본 논문에서는 입술 특징점 검출을 통해 정확한 입술 영역을 검출한 후에 이 정보를 이용하여 AAM을 수행함으로써 얼굴 특징점 검출 정확성을 향상시키는 방법을 제안한다. 본 논문에서는 AAM으로 검출한 얼굴 특징점 정보를 기반으로 초기 입술 탐색 영역을 설정하고, 탐색 영역 내에서 Canny 경계 검출 및 히스토그램 프로젝션 방법을 이용하여 입술의 양 끝점을 추출한 후, 입술의 양 끝점을 기반으로 재설정된 탐색영역 내에서 입술의 칼라 정보와 에지 정보를 함께 결합함으로써 입술 검출의 정확도 및 처리속도를 향상시켰다. 실험결과, AAM 알고리즘을 단독으로 사용할 때보다, 제안한 방법을 사용하였을 경우 입술 특징점 검출 RMS(Root Mean Square) 에러가 4.21픽셀만큼 감소하였다.

일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발 (Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance)

  • 서평원;김유건;한창호;유영기;오춘석
    • 전자공학회논문지SC
    • /
    • 제46권2호
    • /
    • pp.61-71
    • /
    • 2009
  • 본 논문에서는 가정용 게임에 적용 가능한 저가이면서 컴팩트한 모션캡쳐 시스템을 목표로 하고 있다. 현재 영화나 게임에 이용되는 모션캡쳐 시스템은 장비가 크고 상당히 고가이기 때문에 간단한 가정용 게임에는 적용하기 어렵다. 요즘 흔히 사용되는 USB CCD카메라를 이용한 모션캡쳐 게임은 속도가 느리고 2차원 인식만 하는 단점을 가지고 있다. 하지만 최근 연구에서 저가이면서 속도가 빠른 PSD센서를 이용하여 3차원 측정이 가능한 시스템을 구현할 수 있게 되었다. 2차원 측정이 가능한 PSD센서를 이용한 3차원 모션캡쳐 시스템에는 2개 이상의 PSD를 사용하는 스테레오 비전 기반의 PSD 모션캡쳐 시스템과 빛의 세기와 거리와의 관계를 이용하여 하나의 PSD만으로도 3차원 측정이 가능한 광량보정 기반의 단일 PSD 모션캡쳐 시스템 등이 소개되었다. 하지만 현재 개발된 두 시스템을 가정용 게임에 적용하기에는 다음과 같은 문제가 있다. 두 개 이상의 PSD 센서를 사용해야 하기 때문에 고가이고 복잡하다. 광량보정 기반의 단일 PSD 모션캡쳐 시스템의 경우에는 측정된 마커의 광량을 이용하여 거리를 계산하기 하기 때문에 거리측정을 위해 전방향으로 균일한 광량을 가지는 마커를 만들어야 하므로 매우 어렵다. 따라서 본 논문에서는 이러한 문제를 해결한 새로운 접근방법을 소개하고자 한다. 일정한 거리에 떨어져 있는 두 개의 마커가 광학적 특성만 동일하다면 두 마커 사이의 상대적 광량차이를 이용하여 3차원 측정을 할 수 있다는 것이다. 결과적으로 저가이며, 빠르고, 컴팩트하고, 광각이며, 게임에도 적용가능한 단일 PSD 모션 캡쳐 시스템을 개발했다. 이 개발된 시스템이 애니메이션이나 영화, 게임에도 사용되어질 것으로 기대한다.

방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구 (Effect of Scatter Media on Small Gamma Camera Imaging Characteristics)

  • 서현관;최용;임기천;우상근;이준수;송태용;최연성;이경한;김병태;최영일
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2002
  • 방사선원과 감마카메라 사이에 위치한 산란매질의 종류, 두께 그리고 조준기 종류가 감마카메라 영상에 미치는 영향을 고찰하기 위하여 실험과 시뮬레이션을 수행하였다. 감마카메라는 조준기, NaI(T1) 섬광결정(60$\times$60$\times$6 ㎣), 위치민감형 광전자증배관(PSPMT), NIMs, 제어용 컴퓨터를 사용하여 개발하였다. 시뮬레이션은 산란매질(아크릴매질/공기)의 두께 변화(0~8 cm)와 조준기의 종류(평행구멍형조준기/확산형조준기) 변화에 따라 계산하였으며 실험 역시 시뮬레이션과 같은 조건으로 수행하였다. 시뮬레이션 결과를 보면, 매질의 두께가 0 cmn에서 8 cm로 증가하면, 계수율은 평행구멍형조준기의 경우 17%(공기), 60%(아크릴) 감소하였으며 확산형 조준기의 경우 감소율이 더 심하여 각각 86%(공기), 98%(아크릴)의 계수율 감소를 보였다. 실제 실험 결과도 시뮬레이션 결과와 비슷하게 매질의 두께가 0 cm에서 8 cm로 증가하면 평행구멍형조준기의 경우 계수율은 10%(공기), 54%(아크릴) 감소하였으며 확산형조준기의 경우 36%(공기), 63%(아크릴)의 계수율 감소를 보였다. 영상의 공간분해능 역시 매질의 두께가 증가할수록 저하되었다. 연구결과 소형 감마카메라를 임상적으로 사용하고자 할 때 감마카메라를 질환 부위에 최대한 밀착시키고 산란매질 두께를 최소화해야 고효율, 고분해능 영상을 얻을 수 있음을 확인하였다.

  • PDF

감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가 (Development and Performance Test of Preamplifier and Amplifier for Gamma Probe)

  • 봉정균;김희중;이종두;권수일
    • 대한핵의학회지
    • /
    • 제33권1호
    • /
    • pp.100-109
    • /
    • 1999
  • 목적: 핵의학장비를 구성하는 신호처리단의 전단증 폭기와 주증폭기는 방사선의 에너지 정보를 주는 펄스를 분석하는데 중요한 부분이다. 이러한 신호처리부분들은 대부분 크기가 표준화된 상용의 Nuclear Instrument Module (NIM)을 사용한파. 그러나, NIM은 이동형 감마프로브에 사용하기에는 너무 부피가 커서 부적합한 편이다. 이를 위해 본 연구는 이동형 감마프로브에 적합한 소형화된 전단증폭기와 주증폭기를 자체 제작하여 성능평가를 하였다. 대상 및 방법: 본 연구에서 제작된 전단증폭기는 전하민감형 전단증폭기였으며, 주증폭기는 capacitor resistor-resistor capcitor (CR-RC) 회로를 이용하여 제작되었다. 제작 후 성능평가를 위해 $2"{\times}2"$ NaI(T1) 섬광체가 부착된 EP-047 (Bicron Saint-Gobain/Norton Industrial Ceramics Co., Ohio, U.S.A) 검출기와 $1"{\times}1"$ NaI(T1) 섬광체가 부착된 R1535 (Ha-mamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) 검출기를 다중채널분석기인 AccuSpec/A (Canberra Industries Inc., Meriden Conneticut, U.S.A)를 이용 에너지 스펙트럼을 얻었다. NIM은 TC 145 (Oxford Instruments Inc., Oak Ridge, U.S.A)와 TC241 (Oxford Instruments Inc., Oak Ridge, U.S.A)을 이용하였다. 에너지 스펙트럼은 37 kBq ($1{\mu}Ci$) Cs-137과 2.96 MBq ($80{\mu}Ci$) Tc-99m의 방사선원을 이용하여 250초씩 얻었다. 결과: 자체 제작한 진단증폭기와 주증폭기를 EP-047 검출기와 연결하여 얻은 Tc-99m (140 keV)과 Cs-137 (662 keV)의 에너지 분해능은 각각 12.92%, 5.01%이었으며, R1535 검출기를 연결하여 얻은 Tc-99m과 Cs-137의 에너지 분해능은 각각 13.75%, 5.19%이었다. 그리고 NIM을 EP-047 검출기와 연결하여 얻은 Tc-99m과 Cs-137의 에너지 분해능은 14.6%, 718%이었으나, R1535 검출기를 연결하여 얻은 Cs-137 에너지 스펙트럼은 광봉우리 위치가 변화되어 안정되지 못하였고, Tc-99m의 에너지 스펙트럼은 쉽게 얻을 수 없었다. 결론: 본 연구에서 자체 제작한 전단증폭기와 주증폭기는 광증배관의 종류에 관계없이 우수한 성능을 보여주었다. 결론적으로, 본 연구에서 제작한 전단증폭기와 주증폭기는 소형화된 계수용 감마프로브와 영상용 감마프로브에 활용하는데 유용할 것이라고 사료된다.

  • PDF