• Title/Summary/Keyword: Position reliability

Search Result 683, Processing Time 0.03 seconds

Prevalence of dental anomalies among 7- to 35-year-old people in Hamadan, Iran in 2012-2013 as observed using panoramic radiographs

  • Shokri, Abbas;Poorolajal, Jalal;Khajeh, Samira;Faramarzi, Farhad;Kahnamoui, Hanieh Mogaver
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Purpose: This study was performed to evaluate the prevalence of all types and subtypes of dental anomalies among 7- to 35-year-old patients by using panoramic radiographs. Materials and Methods: This cross-sectional study was conducted on 1649 people in Hamadan City, in 2012-2013. The prevalence of four types and 12 subtypes of dental anomalies was evaluated by two observers separately by using panoramic radiography. Dental anomalies were divided into four types: (a) shape (including fusion, taurodontism, and dens invagination); (b) number (including hypodontia, oligodontia, and hyperdontia); (c) structure (including amelogenesis imperfecta, dentinogenesis imperfecta, and dentin dysplasia); and (d) position (including displacement, impaction, and dilacerations). Results: The reliability between the two observers was 79.56% according to the Kappa statistics. The prevalence of dental anomalies diagnosed by panoramic radiographs was 29%. Anomalies of position and number were the most common types of abnormalities, and anomalies of shape and structure were the least in both genders. Anomalies of impaction (44.76%), dilacerations (21.11%), hypodontia (15.88%), taurodontism (9.29%), and hyperdontia (6.76%) were the most common subtypes of dental anomalies. The anomalies of shape and number were more common in the age groups of 7-12 years and 13-15 years, respectively, while the anomalies of structure and position were more common among the other age groups. Conclusion: Anomalies of tooth position were the most common type of dental anomalies, and structure anomalies were the least in this Iranian population. The frequency and type of dental anomalies vary within and between populations, confirming the role of racial factors in the prevalence of dental anomalies.

The Correlation Between Forward Head Position and Neck Flexor Thickness During Cranio-Cervical Flexion Exercise (머리-목굽힘 운동 시 앞쪽머리자세와 목굽힘근 근두께 간의 상관성 연구)

  • Lee, Ji-Min;Yu, Jun-Su;Lim, Ji-Eun;Lee, Hyun-Ah;Moon, Sung-Gi;Jang, Hyun-Jeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Background: As the increase of forward head position, we studied the change of thickness of deep cervical flexor (DCF) compared of with sternocleidomastoid (SCM). we measured and analysed the change of thickness of the neck flexor for forward head position and cranio-cervical flexion exercise (CCFE). Methods: Using a cross-sectional design, we conducted the study selecting 35 healthy adults (12 males, 23 females). We measured the craniovertebral angle (CVA), instructed them to perform the CCFE, and measured the DCF and SCM using ultrasonography during the contraction and relaxation period. Results: Intra-reliability of SCM is .96, longus capitis is .92 and longus coli is .97. we compared according to the change of forward head position, Correlation of DCF is .841, and DCF/SCM is .754 by significant positive correlation. At the comparison of CCFE and Resting muscle thickness, SCM and DCF is .00, DCF/SCM is .68. Conclusion: There is a strong positive correlation between the change amount of DCF and DCF/SCM as the increase of CVA.

A study on the determining of vertical dimension of occlusion of edentulous patients using korean phonetic patterns (한국어 음성모형을 이용한 총의치 환자의 교합고경 결정에 관한 연구)

  • Song, Kwang-Seob;Song, Kwang-Yeob;Cho, Kook-Hyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.187-196
    • /
    • 2000
  • This study was performed to offer convenience to determine the vertical dimension of occlusion of edentulous patients by investigating the interocclusal distances at physiologic rest position, at speaking of /m/ sound, and some korean short sounds, that is, /mem/ and /beb/ sounds, which were found in our previous study with dentulous subjects. Ten edentulous subjects - 6 men and 4 women - were selected for this study. The frequencies at speaking of /m/, /mem/, and /beb/ sounds were analyzed with Computerized speech lab($CSL^{TM}$, Model 4300B, Software version 5.X, Kay Elemetrics Co. U.S.A.). And the interocclusal distances at physiologic rest position and at speaking of /m/, /mem/, and /beb/ sounds were measured with K6 diagnostic system(Myo-tronics, Inc. U.S.A.). The results of this study were as follows ; 1. In the acoustic analysis by Computerized speech lab, frequencies of sounds of edentulous subjects with complete denture at speaking of /m/, /mem/, and /beb/ were similar to those of dentulous subjects. 2. In the linear correlation by Pearson's correlation coefficient, the interocclusal distance at physiologic rest position was most similar to those of speaking /mem/ sound, secondly /m/ sound, and thirdly /beb/ sound(p<0.05). In reliability by Cronbach's alpha, the results were reliable with alpha value 0.97. 3. It was found by Levene's test for equality of variance that the difference between men and women in the interocclusal distances at physiologic rest position and at speaking of /m/, /mem/, and /beb/ sounds was not statistically significant(p>0.05).

  • PDF

Determination of Optimal Support Position and Stability for Manufacturing Filter Screen for Ships Using Wedge Wires (웨지 와이어를 이용한 선박용 필터 스크린 제작을 위한 최적 지지 위치 및 안정성 판단)

  • Son, In-Soo;Seo, Byung-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.263-269
    • /
    • 2022
  • In this study, the optimal support position determination and stability determination of the wedge wire screen were performed for the production of the wedge wire filter screen with improved mesh screen. In order to manufacture a filter screen using a wedge wire, the support rod wedge wire is first installed according to the filtering capacity, and then spot welding is performed while rotating the profile wire. In the existing manufacturing method, it was manufactured using a 3m rod wedge wire and then cut according to dimensions, but it required the manufacture of a 6m cylindrical screen. Due to the increase in wedge wire length, it is difficult to manufacture stress concentration at sagging and fixed positions. In order to shorten the time of analysis, a single wedge wire was applied instead of a plurality of wedge wires. The reliability and validity of the interpretation were presented and the results were derived. After selecting the support point at the 2m position, structural analysis was performed on the entire filter screen to confirm stability.The purpose of this study is to identify the maximum deflection of the wire for the production of a 6m wedge wire screen and secure design basic data so that it can work safely through optimal support.

A Study on the Estimation of Ship Location Information in the Intelligent Maritime Traffic Information System (지능형 해상교통정보시스템의 선박 위치 정보 추정 연구)

  • Deuk-Jae Cho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.06a
    • /
    • pp.313-314
    • /
    • 2022
  • The intelligent maritime traffic information service provides a service to prevent collisions and stranding of ships based on the location information of ships periodically collected from ship equipment such as LTE-Maritime transceivers and AIS installed on ships. provided in real time. However, the above service may reduce the reliability of ship location information because GPS location information for measuring the ship's location may be cut off during transmission through LTE-Maritime or AIS networks, or phenomena such as location jumps and delays may occur. This study aims to estimate reliable position information to some extent even in an abnormal section through ship position prediction based on the existing received position information using the Kalman filter, which is an optimal estimation filter based on probability.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF

Optimal Design of Press-Fitted Axle Shaft Considering Stress Relief (압입축의 손상저감을 위한 최적설계 연구)

  • Ko, Jaechun;Lee, Jongsoo;Choi, Ha-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.859-864
    • /
    • 2013
  • Creation of a stress relief groove is a fairly simple yet high-performance method. During the application of this method, it is important to consider the location and size of the groove in order to achieve better performance. Consequently, this research proposes an approach for optimizing the application of the stress relief groove method to a press-fitted assembly. In a boss design, the position and diameter of the groove are configured as design variables and the design of experiments is applied. Based on this information, a 3D model is built and analyzed using the finite element analysis software ABAQUS. Meta-models are created using back-propagation neural networks. Then, deterministic optimization results obtained from a genetic algorithm are compared with the results of the finite element analysis. The temperature sensitivity of the optimized model is analyzed, and finally, reliability-based design optimization is conducted for enhancing the design quality.

Greedy Anycast Forwarding Protocol based on Vehicle Moving Direction and Distance (차량의 이동 방향과 거리 기반의 그리디 애니캐스트 포워딩 프로토콜)

  • Cha, Siho;Lee, Jongeon;Ryu, Minwoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.1
    • /
    • pp.79-85
    • /
    • 2017
  • Vehicular ad-hoc networks (VANETs) cause link disconnection problems due to the rapid speed and the frequent moving direction change of vehicles. Link disconnection in vehicle-to-vehicle communication is an important issue that must be solved because it decreases the reliability of packet forwarding. From the characteristics of VANETs, greedy forwarding protocols using the position information based on the inter-vehicle distance have gained attention. However, greedy forwarding protocols do not perform well in the urban environment where the direction of the vehicle changes greatly. It is because greedy forwarding protocols select the neighbor vehicle that is closest to the destination vehicle as the next transmission vehicle. In this paper, we propose a greedy anycast forwarding (GAF) protocol to improve the reliability of the inter-vehicle communication. The proposed GAF protocol combines the greedy forwarding scheme and the anycast forwarding method. Simulation results show that the GAF protocol can provide a better packet delivery rate than existing greedy forwarding protocols.

Evaluation of Mechanical Properties and FEM Analysis on Thin Foils of Copper (구리 박막의 기계적 물성 평가 및 유한요소 해석)

  • Kim Yun-Jae;An Joong-Hyok;Park Jun-Hyub;Kim Sang-Joo;Kim Young-Jin;Lee Young-Ze
    • Tribology and Lubricants
    • /
    • v.21 no.2
    • /
    • pp.71-76
    • /
    • 2005
  • This paper compares of mechanical tensile properties of 6 kinds of copper foil. The beam lead made with copper foil. Different from other package type such as plastic package, Chip Size Package has a reliability problem in beam lead rather than solder joint in board level. A new tensile loading system was developed using voice-coil actuator. The new tensile loading system has a load cell with maximum capacity of 20 N and a non-contact position measuring system based on the principle of capacitance micrometry with 0.1nm resolution for displacement measurement. Strain was calculated from the measured displacement using FE analysis. The comparison of mechanical properties helps designer of package to choose copper for ensuring reliability of beam lead in early stage of semiconductor development.