• 제목/요약/키워드: Position reliability

검색결과 674건 처리시간 0.029초

Reliability of Navicular Drop Measurements in Standing and Sitting Positions

  • Park, Ji-Won;Chang, Jong-Sung;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: This study was designed to investigate inter-rater and intra-rater reliability of navicular drop measurements by clinicians in sitting and standing positions. Methods: Fourteen subjects with pronated foot were recruited. Two physical therapists randomly assessed the same patients on different occasions but on the same day. Almost all patients were assessed on more than one day. The intra-rater and inter-rater reliability of navicular dropwas estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of navicular drop measurements ranged from 0.93 to 0.87, the inter-rater reliability from 0.98 to 0.70 with the patient in standing and sitting positions. These results showed good reliability for calculated variables. Intra-rater and inter-rater reliability of navicular drop in standing position was higher than those of sitting position. Conclusion: Although inter-rater and intra-rater reliability of navicular drop in the sitting position was lower than in the standing position, measurement of navicular drop in the sitting position showed good reliability and was acceptable for patients who could not stand alone without assistance. We recommend that having the patient in the standing position is appropriate in navicular drop measurement.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권1호
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도 (Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion)

  • 홍완성;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

측두하악관절의 초음파영상과 자기공명영상에서 하악과두 외측면과 관절낭간 거리 측정치 비교 (Comparison of the capsular width measured on ultrasonogrape and MR image of the temporomandibular joint)

  • 이태완;유동수;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.41-48
    • /
    • 2006
  • Purpose : To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint (TMJ). Materials and Methods : Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonographs of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonograph of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonographs was compared, according to mouth position and disc postion. Results : The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position were 0.92 and 0.81. The measurement error was 0.4% and 0.7%. At the TMJ with normal disc position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonographs were $2.0{\pm}0.7mm,\;1.8{\pm}0.5mm$, respectively (p<0.05). On the ultrasonographs, the distances at open mouth position were $1.2{\pm}0.5mm$ (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were $1.3{\pm}0.3\;mm\;and\;0.9{\pm}0.2\;mm$ (p<0.05). Conclusion : The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  • PDF

연조직두께 측정기구(SDM)의 재현성에 관한 연구 (A Study on the Reliability of an Ultrasonic Measurement Device(SDM))

  • 장문택;김형섭;이광원
    • Journal of Periodontal and Implant Science
    • /
    • 제30권2호
    • /
    • pp.483-490
    • /
    • 2000
  • The aim of this study was to analyze the reliability of an ultrasonic device(SDM) measuring soft tissue thickness in relation to tooth position, and to find factors which can influence the reliability. The results showed that 1. measurement error was the largest in the maxillary second molar position and the smallest in the mandibular central incisor position. 2. in a box whisker plot, the difference between two measurements was most widely distributed in molar positions. 3. in Pearson correlation analysis, the relationship between two measurements was the highest in the maxillary lateral incisor position and, the lowest in the maxillary second molar, mandibular first and second premolar position. 4. a stepwise multiple regression analysis could explain the difference of two measurements with various independent variables in 29.7% (P<0.0001). Gingival thickness was the only variable influencing the measurement difference in a statistically significant level(P<0.0001). It can be concluded that its high reliability, ease to use and patient comfort justified the application of the SDM in measurement of soft tissue thickness.

  • PDF

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Validity and Reliability of New Digital Navicular Drop Test Equipment in Young People

  • Park, Jin-Seong;Park, Du-Jin
    • PNF and Movement
    • /
    • 제19권2호
    • /
    • pp.279-285
    • /
    • 2021
  • Purpose: This study aimed to develop new digital navicular drop test (ND-NDT) equipment and to determine its validity and reliability. Methods: A total of 24 healthy male and female adults, who fully understood the purpose of the study and gave consent to participate in the study, were selected as participants. The NDT and ND-NDT were conducted in the dominant foot of the participants in a random order. For the NDT, the position of the navicular bone was marked with a pen first; then, the height of the navicular bone from the ground was measured in both sitting and standing positions. For the ND-NDT, after the sticker-type reflection markers were attached to the position of the navicular bone, the height of the navicular bone from the ground was measured in both sitting and standing positions. To assess the validity of the diagnostic tests, the same examiner measured the height of the medial longitudinal arch (MLA) three times in both the sitting and standing positions. To assess the inter-rater reliability of the ND-NDT, three examiners, in a random order, attached the sticker-type reflection markers to the position of the navicular bone and then measured the height of the MLA in both positions. Results: In the sitting position, the Pearson correlation coefficient (r) between the two diagnostic tests was very high (r = 0.97) and statistically significant. In the standing position, the Pearson correlation coefficient (r) between the two tests was 0.95, which was also statistically significant. The ICC2,1 values in the sitting and standing positions were 0.93 and 0.95, respectively, indicating significantly high inter-rater reliability. Conclusion: The ND-NDT equipment showed very high diagnostic validity, as well as excellent inter-rater reliability, indicating the clinical usefulness of the equipment as a diagnostic system for confirming pes planus.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.