• Title/Summary/Keyword: Position measurement

Search Result 2,294, Processing Time 0.029 seconds

A simulation of Rotor Position Estimation of SRM using Flux linkage Modeling (SRM의 쇄교자속 모델링을 통한 회전자 위치 추정기법의 시뮬레이션)

  • Baik Won-Sik;Kim Nam-Hun;Kim Dong-Hee;Choi Kyeong-Ho;Kim Min-Huei
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.36-39
    • /
    • 2002
  • This paper presents a simulation results of sensorless control of Switched Reluctance Motor(SRM) using neural network. The basic algorithm of this scheme is based on the flux linkage characteristic according to the phase current and the rotor position. A sufficient simulation data was used for neural network training. Through measurement of the phase flux linkage and phase currents the neural network is able to estimate the rotor position. The simulation result shows some good results, and possibility of this algorithm.

  • PDF

Precision Evaluation Method for the Positioning Error of Three-DOF Parallel Mechanism using Coordinate Measuring Machine (CMM) (CMM을 이용한 3자유도 병렬기구 위치 오차의 정밀 평가 기법)

  • 권기환;박재준;이일규;조남규;양현익
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.99-109
    • /
    • 2004
  • This paper proposes precision evaluation method for the positioning error of three-DOF translational parallel mechanism. The proposed method uses conventional CMM as metrology equipment to measure the position of end-effector. In order to obtain accurate measurement data from CMM, the transform relationship between the coordinate system of the parallel mechanism and the CMM coordinate system must be identified. For this purpose, a new coordinate referencing (or coordinate system identification) technique is presented. By using this technique accurate coordinate transformation relationships are efficiently established. According to these coordinate transformation relationships, an equation to calculate error components at any arbitrary position of the end-effector is derived. In addition, mathematical fitting models to represent the position error components in the two-dimensional workspace of the parallel mechanism are also constructed based on response surface methodology. The proposed error evaluation method proves its effectiveness through the experimental results and its application to real three-DOF parallel mechanism.

Measuring Method of In-plane Position Based On Reference Pattern (레퍼런스 패턴 기반 면내 위치 측정 방법)

  • Jung, Kwang Suk
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Generally, in-plane position of moving object is measured referring to the reference pattern attached to the object. From optical camera to magnetic reluctance probe, there are many ways detecting a variation of the periodical pattern. In this paper, the various operating principles developed for in-plane positioning are reviewed and compared each other. And, a novel method measuring large rotation as well as x, y linear displacements is suggested, including a detailed description of the overall system layout. It is a modified version of the surface encoder, which is a robust digital measuring method. From the surface encoder, the rotation of an object is measured indirectly through a compensated input of optical servo and independently of linear displacements. So, the operating range can be extended simply by enlarging the reference pattern, without magnifying the decoding units.

  • PDF

Characteristics of Relative Navigation Algorithms Using Laser Measurements and Laser-GPS Combined Measurements

  • Kang, Dae-Eun;Park, Sang-Young;Son, Jihae
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.287-293
    • /
    • 2018
  • This paper presents a satellite relative navigation strategy for formation flying, which chooses an appropriate navigation algorithm according to the operating environment. Not only global positioning system (GPS) measurements, but laser measurements can also be utilized to determine the relative positions of satellites. Laser data is used solely or together with GPS measurements. Numerical simulations were conducted to compare the relative navigation algorithm using only laser data and laser data combined with GPS data. If an accurate direction of laser pointing is estimated, the relative position of satellites can be determined using only laser measurements. If not, the combined algorithm has better performance, and is irrelevant to the precision of the relative angle data between two satellites in spherical coordinates. Within 10 km relative distance between satellites, relative navigation using double difference GPS data makes more precise relative position estimation results. If the simulation results are applied to the relative navigation strategy, the proper algorithm can be chosen, and the relative position of satellites can be estimated precisely in changing mission environments.

Development of position correction system of door mounting robot based on point measure: Part ll-Measurement and implementation (특정점 측정에 근거한 도어 장착 로봇의 위치 보정 시스템 개발: Part II - 측정및 구현)

  • Byun, Sung Dong;Kang, Hee Jun;Kim, Sang Myung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.42-48
    • /
    • 1996
  • In this paper, a position correction system of industrial robot for door-chassis assembly tast is developed in connection with the position correction algorithm shown in Part I. Tow notches and a hole of auto chassis are selected as the reference measure points and a vision based error detection algorithm is devised to measure in accuracy of less than 0.07mm. And also, the transformation between base and tool coordinates of the robot is shown to send the suitable correction quantities caaording to robot's option. The obtained algorithms were satisfactorily implemented for a real door-chassis model such that the system could accomplish visually acceptable door-chassis assembly task.

  • PDF

Real-Time Determination of Relative Position Between Satellites Using Laser Ranging

  • Jung, Shinwon;Park, Sang-Young;Park, Han-Earl;Park, Chan-Deok;Kim, Seung-Woo;Jang, Yoon-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.351-362
    • /
    • 2012
  • We made a study on real-time determination method for relative position using the laser-measured distance data between satellites. We numerically performed the determination of relative position in accordance with extended Kalman filter algorithm using the vectors obtained through nonlinear equation of relative motion, laser simulator for distance measurement, and attitude determination of chief satellite. Because the spherical parameters of relative distance and direction are used, there occur some changes in precision depending on changes in relative distance when determining the relative position. As a result of simulation, it was possible to determine the relative position with several millimeter-level errors at a distance of 10 km, and sub-millimeter level errors at a distance of 1 km. In addition, we performed the determination of relative position assuming the case that global positioning system data was not received for long hours to see the impact of determination of chief satellite orbit on the determination of relative position. The determination of precise relative position at a long distance carried out in this study can be used for scientific mission using the satellite formation flying.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

Development of body position sensor device for posture correction training (자세 교정훈련을 위한 체위 변환 감지 센서 디바이스의 개발)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Recently the incidence of musculoskeletal disorders in students and office workers is increasing, and the necessity of maintaining correct posture and corrective training is required, but related research is insufficient. In the previous study, a membrane sensor or a pressure sensor was placed on the seat cushion to see the deviation of the body weight, or a sensor that restrained the user was attached to measure the position change. In this study, a sensor device for detecting a position change in consideration of wearing comfort was developed, and the measured angle was verified through an analysis app. A sensor device consisting of an IMU sensor is attached to the cervical spine and vertebra spine to measure the position transformation in the sitting position. The change value of the position measured by the two sensors was converted into an angle, and the angle value is displayed in real time through the analysis app. In this study, the possibility of measuring the real-time change value according to the change in position, the convenience of wearing, and the tendency of angle measurement were proved. Future research should proceed with more precise angle calculation and correction of motion noise.

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

Accuracy Improvement of Stereo-Based Distance Measurement for Close Range Vessel Positioning

  • Ogura, Tadashi;Mizuchi, Yoshiaki;Kim, Young-Bok;Choi, Yong-Woon
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.27-32
    • /
    • 2015
  • This paper describes a distance measurement system with high accuracy that utilizes a stereo-based camera and a pan-tilt unit for automatically maintaining the positional relationship between a vessel and a target on the side of a facility at a close range. The measurement system offers an advantage in that it can measure the distance to a target while tracking it. In order to improve the ability to control the position of a vessel between it and a target while maintaining the distance especially at a close range, the accuracy of the measurement system has to be improved. The accuracy of the distance measured by our system is increased with revisions of the conclusively generated data of distance measurement. We verified the accuracy of our system from an experiment, which generated results that had an accuracy of 30 mm for distances in the range between 2-8 m.