• Title/Summary/Keyword: Position measurement

Search Result 2,294, Processing Time 0.035 seconds

Effect of mobile terminal searcher on TDOA position location technique (TDOA 위치추정기법에서의 단말기 Searcher의 영향)

  • 김정태;서덕영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7A
    • /
    • pp.1022-1027
    • /
    • 1999
  • This paper proposes method that uses Time-Difference-of-Arrival(TDOA) of Forward Pilot signals from base stations(BS) arriving at a mobile station(MS) as a position location method of CDMA MS. MS searcher does acquisition of BS Pilot signals and measurement of TDOAs. In order to do it, its processing gain is very important. Proportional relationship of the gain to the signal coherent integration interval is theoretically derived and analyzed and field test is performed to show acquisition of weak Pilot signals and stable measurements of TDOA values by increasing the gain. Also, signal strength decrease exponentially by the distance it travels. Therefore, improvement of the searcher gain makes possible to acquire Pilot signals at a location far away from BS. Variation of possible position estimation area relative to the signal strength within a cell is simulated with computer. Neglecting shadow effect it indicated necessity of detecting signals below -35dB in order to cover over 90% of cell area. Thus, efforts to maximize searcher coherent integration interval in order to acquire weak Pilot signals are required for expansion of position estimation area and measurement of stable TDOA values.

  • PDF

AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT (인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사)

  • Park Chang-Seo;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF

Using DGPS as An Acceleration Sensor for Airborne Gravimetry

  • Zhang, Kaidong;Shen, Lincheng;Hu, Xiaoping;Wu, Meiping
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.327-332
    • /
    • 2006
  • In airborne gravimetry, there are two data streams. One is the specific force measured by an air/sea gravimeter or accelerometers, the other is kinematic acceleration measured by DGPS. And the difference of them provides the gravity disturbance information. To satisfy the requirement of most applications, an accuracy of 1mGal $(1mCal=10^{-5}m/s^{2})$ with a spatial resolution of 1km is the aim of current airborne gravimetry. There are two different methods to derive the kinematic acceleration. The generally used method is to differentiate the position twice, and the position can be calculated by commercial DGPS software. The main defect of this method is that integer ambiguities need to be fixed to get the precise position solution, but it's not a trivial thing for long base line. And to fix integer ambiguities, the noisier iono-free measurement is used. When differentiation is applied, noise is amplified and will influence the accuracy of acceleration. The other method is to get carrier phase acceleration by differentiate the carrier phase first, and then using the acceleration of GPS satellite to derive the vehicle acceleration. The main advantages include that fixing integer ambiguities is not needed anymore, position can be relaxed to about 10 meters, and smoother acceleration can be got since iono-free measurement is not needed. In some literatures, it's considered that the dynamic performance of the second method is inferior to that of the first. Through analysis, it is found that the performance degradation in dynamic environment results from the simplification of the GPS carrier phase observable model. And an iterative algorithm is presented to compensate the model error. Using a dynamic GPS data from an aeromagnetic survey, the importance of this compensation is showed at last.

  • PDF

Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture (안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구)

  • Jeong, Seong Ho;Shin, Seung Han;Park, Seung Ha;Koo, Sang Hwan
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.

Indoor Navigation System for Visually Impaired Persons Using Camera and Range Sensors (카메라와 거리센서를 이용한 시각장애인 실내 보행안내 시스템)

  • Lee, Jin-Hee;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.4
    • /
    • pp.517-528
    • /
    • 2011
  • In this paper, we propose an indoor navigation system that can do walk safely to the destination for visually impaired persons. The proposed system analyzes images taken with the camera finds the ID of the marker to identify the absolute position of the pedestrian. Using the distance and angle obtained from IMU(Inertial Measurement Unit) accelerometer sensor and a gyro sensor, the system decides the relative position of a pedestrian for the previous position to determine the next direction. At the same time, we simplify a complex spatial structure in front of user by means of ultrasonic sensors and determine an avoidance direction by estimating the patterns. Then, it uses a few IR(Infrared Rays) sensors to detect stair. Our system offers position of visually impaired persons incorporating multiple sensors and helps users to arrive to destination safely.

Evaluating the Accuracy of Blood Pressure Measurement in General Hospital Nurses (종합병원 간호사의 혈압측정의 정확성 평가)

  • Kim Jong-Sook;Kim Sang-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • To assess the accuracy of blood pressure measurement in general hospital nurses, 276 nurses at four hospital in Kyungju city and Pohang city were observed during the study period 20 December 1998 to 29 December 1998. The nurses measuring the blood pressure of simulated patient's were checked by the researcher or 20 items, that are recommended for consideration when doing a blood pressure measurement. Of the six items in the preparation step for measuring blood pressure, the accuracy of 'patients shouldn't talk during the procedure' had the lowest frequency(27.1%) and the other five items were above 80%. Of the ten items on blood pressure measuring technique, the accuracy of the frequency for 'inflating the cuff until the radial or brachial artery pulse is no longer palpable and then adding 30mmHg' was 0%, 'waiting $30{\sim}60$ seconds before reinflating the cuff' was alse 0%, 'rapidly deflating the cuff', 0.3%, 'rapidly and steadily inflating the cuff to the maximal level as per above-mentioned initial systolic pressure assessment step', 0.7%, 'reading the pressure to the nearest 2mmHg mark on the manometer', 10.8%, the remaining items were above 70%. Of the four items on blood pressure recording, the accuracy of 'recording the cuff size' had a frequency of 0.3%, 'recording the patient's position such as sitting, standing or lying position', 10.8%, 'recording the arm or leg which was used for measuring the blood pressure', 53.6%, and 'recording systolic/diastolic pressure', 100%. The variables significantly related to the accuracy of the blood pressure measurement were age, career position at hospital, and qualification education for blood pressure measurement(p<0.01). In the multiple regression analysis, position and qualification education were significant variables(p<0.01). In conclusion, the accuracy of blood pressure measurement was very low, thus, qualification education for blood pressure measurement should be done immediately to improve the accuracy of measurement by nurses in general hospitals.

  • PDF

A Study on the Influence of Wearing-Girdle on the Various Physiological Function (Girdle 착용이 신체 제 기능에 미치는 영향에 관한 연구)

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 1990
  • This study was carried out to investigate the influence of the various physiological function caused by girdle wearing. The four experimental methods used in this study are as follows. For example, the Reentgen photographing, body measurement by Sliding Gauge, mensurement of the electrocardiogram, measurement of the pulse and the blood pressure. The results of the investigation were as follows; 1. In the change of the various organs by Roentgen photographing, the diaphragm rised a little than normal position. The heart and stomach inclined to right side and the shape of stomach and duodenum are longer than the length of normal shape. Especially the phlorus of stomach was pressured strongly. 2. In the experimental change by the Sliding gauge and body measurement, the waist, hip and theigh girth of wearing-girdle reduced than at the no-girdle. The protruson of abdomen and hip section of wearing-girdle and the phenomenon of Hip-Up showed. 3. The difference by measurement of the electrocardiogram wasn't showed. The pulse of the wearing-girdle was increased slightly than the no-girdle. 4. The blood pressure of the wearing-girdle decreased slightly than the no-girdle.

  • PDF

Complete Parameter Identification of Gough-Stewart platform with partial pose measurements using a new measurement device

  • Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.825-830
    • /
    • 2004
  • Kinematic calibration of Gough-Stewart platform using a new measurement device is presented in this paper. The device simultaneously measures components of position and orientation using commercially available gadgets. Additional kinematic parameters are defined to model the sources of inaccuracies for the proposed measurement device. Computer simulations reveal that all kinematic parameters of the Gough-Stewart platform and the additional kinematic parameters of the measurement device can be identified with the partial pose measurements of the device. Results also show that identification is robust for the initial errors and the noise in measurements. The device also facilitates the automation of easurement procedure.

  • PDF

Tip Enhanced Nano Raman Scattering in Graphene

  • Mun, Seok Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.87.2-87.2
    • /
    • 2016
  • As an era of nano science approaches, the understanding on the shape and optical properties of various materials in a nanoscale range is getting important more seriously than ever. Accordingly the development of high spatial-temporal-spectral resolution measurement tools for characterization of nanomaterials/structures is highly required. Generally, the various properties of sample can be measured independently, e.g. to observe the structural property of sample, we use the scanning electron microscopy or atomic force microscopy, and to observe optical property, we have to use another independent measurement tool such as photoluminescence spectroscopy or Raman spectroscopy. In the case of nano-materials, however, it is very difficult to find out the same position of sample at every different measurement processes, and the condition of sample can be changed by the influence of first measurement. The tip enhanced Raman scattering(TERS), which can simultaneously measure the two or more information of sample with nanoscale spatial resolution, is one of solutions of this problem. In this talk, I will present our recent nano Raman scattering data of graphene that measured by TERS and optimized tip fabrication method for efficient experiment.

  • PDF

A New Velocity Measurement Method using Linear Type Hall-effect Sensor for Electro-mechanical Fin Actuator (선형홀센서를 이용한 전기식 구동장치의 속도 신호 구현)

  • Gu, Jeong-Hoi;Song, Chi-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.70-75
    • /
    • 2010
  • The objective of this paper is to propose a new velocity measurement method for an electro-mechanical fin actuator. The model of the electro-mechanical fin actuator includes uncertainties such as unknown disturbances and parameter variations in flight condition. So, an electro-mechanical fin actuator system needs robust control algorithm which requires not only position information but also velocity information. Usually, analog tachometers have been used for velocity feedback in an electro-mechanical fin actuator. However, using these types of sensors have problems such as the cost, space, and malfunction. These problems lead to propose a new velocity measurement method using linear type Hall-effect sensor. In order to verify the proposed method, several experiments are performed using Model Following Sliding Mode Controller(MFSMC). It is shown that the MFSMC with a new velocity measurement method using linear type Hall-effect sensor can satisfy the requirements without using of velocity sensor.