• Title/Summary/Keyword: Position measurement

Search Result 2,290, Processing Time 0.031 seconds

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Relations between emotional labor and job stress among some dental hygienists (일부 치과위생사의 감정노동과 직무스트레스와의 관계)

  • Yoon, Song-Uk;Kim, Jung Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.179-188
    • /
    • 2011
  • Objectives : The study set out to analyze correlations between emotional labor and job stress among dental hygienist, who have direct and lasting relationships with patients in dental clinic, and provide basic data to resolve stressors and manage stress. Methods : A survey was taken among dental hygienists working at dental clinics, and 200 questionnaires were used in analysis. The gathered data were put to Cronbach's alpha with the SPSS WIN12.0 program to test the reliability of the inventories to measure their emotional labor and job stress. In addition, correlation analysis was conducted to examine relations between the items of emotional labor and those of job stress along with regression analysis to examine relations between emotional labor and job stress. Finally, t-test and One-way ANOVA were conducted to test mean differences in the job stress items according to the degrees of emotional labor with the statistical significance level set at 0.05. Results : 1. The measurement tool used in the study recorded 0.7 for all the areas of Cronbach's alpha for internal reliability and thus achieved high reliability. 2. The overall mean of emotional labor was 2.74, which indicates that the dental hygienists had 'average' or higher stress for emotional labor. 3. Emotional labor had statistically significant relations with educational background, place of work, motivation to choose to be a dental hygienist, and religion of their general characteristics. 4. There was statistical significance in relations between general characteristics and job stress according to educational background, position at work, and experience with change of occupation. 5. The correlations between emotional labor and the stress areas were analyzed. As a result, emotional labor was in positive(+) correlations with job demand, lack of job autonomy, relational conflict, job instability, organizational system, and corporate culture. In addition, regression analysis was conducted to test causal relations between emotional labor and job stress. The results indicate that there were positive(+) influences between emotional labor and job stress. Conclusions : The results show that emotional labor can serve as a mediating variable for job stress in dental clinic. Thus both dental clinics and dental hygienists need to have ways to deal with job stress derived from emotional labor in which they are forced to process their emotions according to the dental clinics' demands, properly. The study will hopefully trigger ongoing follow-up researches on the deployment of dental hygienists according to their job characteristics and the situational variables to alleviate the negative results of emotional labor.

Calibration Kit for 4-Port Horizontal/Vertical Probing (4-포트 수평/수직 겸용 프로브용 교정키트)

  • Kim, Taeho;Kim, Jonghyeon;Kim, Sungjun;Kim, Kwangho;Pu, Bo;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.559-575
    • /
    • 2014
  • In this paper, we propose a horizontal/vertical calibration kit for calibrating a vector network analyzer(VNA) to measure the vertical connector pin. If the conventional calibration kit is used, we should change the arm for a probe or need an assistant device and it takes a long time. In addition there is a risk of precision degradation caused by the position change of the probe tip sensitive to the surroundings. We suggest a 4-port vertical calibration kit to make up for the aforementioned shortcomings. The calibration kit was manufactured for the SOLT calibration method. 'Short', 'Open', and 'Load' are available in the horizontal plane, 'Thru' is available not only in the horizontal plane on the two planes of a PCB, but in the vertical plane between the two planes according to the positions of the probes. We complemented the conventional calibration kit to make a vertical calibration kit to be used for the vertical measurement method. We compared and analysed their reflection/transfer characteristics of the SOLT calibration standards of the proposed calibration kit and conventional one, we get a ${\pm}0.1$ dB differences of transfer characteristics in the range from 300 kHz to 8.5 GHz. In order to demonstrate usefulness, and we performed a case study for horizontal and vertical cases, and compared the results of the proposed calibration kit and conventional one.

Measurement and Comparison of Morphology of Developmental Stages of Chestnut Weevil, Curculio sikkimensis(Coleoptera: Curculionidae) (밤바구미 (Curculio sikkimensis)의 발육단계별 형태측정 및 비교)

  • Kim, Young-Jae;Moon, Sang-Rae;Yoon, Chang-Mann;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.49 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • Measurements were made on morphology of each developmental stages of the chestnut weevil, Curculio sikkimensis, reared in the laboratory and field from 2003 to 2006. The size of egg was 0.8${\pm}$0.03 mm. The escaping larvae were measured, in average, as 98 mg in body weight, 10.65 and 3.99 mm in body length and width, and 1.70 mm in head width. Pupal size of female and male was 7.01 and 6.53 mm, respectively. The fresh weight (0.343 g), body length (7.76 mm) and width (3.38 mm), and head width (1.60 mm) of female adults were significantly bigger than those (0.268 g, 7.14 mm, 3.01 mm and 1.37 mm, respectively) of male adults. Proboscis length (6.53 mm) and antennal length (5.47 mm) of female was also significantly longer than those (3.56 and 4.63 mm, respectively) of male. The larvae of C. sikkimensis overwintered for 1~3 years and their body weight, body length, and body width were decreased. The ratio between proboscis length and body length, the basipodite position attached to the proboscis, and shape of the sex organ on the abdominal end could be used to discriminate sexes.

CEPHALOMETRIC ANALYSIS OF UPPER AND LOWER INCISORS IN DIFFERENTIAL FACIOSKELETAL PATTERN (악골형태에 따른 상하악절치위치에 관한 측모 두부방사선 계측학적 분석)

  • Kim, Jung-Ho;Kwon, Oh-Won;Kim, Jung-Min
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.735-753
    • /
    • 1992
  • The purpose of this study was to analyze the positions of upper and lower incisors according to facioskeletal patterns. The lateral cephalometric radiographs of sixty persons with normal occlusion, forty persons with Class II Division 1 malocclusion, and forty persons with Class III malocclusion all above the age of 18, were analyzed. The following results were obtained. 1. C I angle, the measurement related to masticatory system, were $89.20{\pm}4.34^{\circ}$ in normal occlusion group, $81.68{\pm}士5.95^{\circ}$ in Class II Division 1 malocclusion group and $101.96{\pm}6.31^{\circ}$ in Class III malocclusion group. 2. In comparison with the positions of upper and lower incisors according to facioskeletal patterns, Class II Division 1 malocclusion group showed that upper incisors were different significantly in all measurements and inclined labially (P < 0.05). Lower incisors were different significantly in all measurements except LI-APog, LI-APog (mm), LI-AB, LI-AB (mm) and inclined labially (P < 0.05), Class III malocclusion group showed that upper incisors were different significantly in all measurements except UI-SN, UI-OP, and inclined labially (P < 0.05). Lower incisors were different significantly in all measurements and inclined lingually (P < 0.05). 3. In all facioakeletal patterns, LI-SN and LI-PH ware correlated moderately to facioskeletal measurements, and FMA was correlated moderately to measurements of lower incisor position. 4. Regardless of the facioskeletal patterns, the reference planes equally applicable were AB line in the measurements of upper incisor and APog line in the measurements of lower incisor.

  • PDF

Measurement of Optical Purity for Commercially Avialable Naproxen Sold in 2013 (2013년 시판된 나프록센의 광학순도 측정)

  • Seo, Hae Chan;Song, Jung Suk;Ryoo, Sang Hyun;Lee, Sang Heon;Ryoo, Dong Hyun;Yu, Jeong Jae;Ryoo, Jae Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.2
    • /
    • pp.179-185
    • /
    • 2014
  • Commercial (S)-naproxen was racemized under strong basic condition. After checking the peak position of (R)- and (S)-naproxen by analysis the recemized naproxen, optical purity of 19 commercialized naproxens sold in 2013 in Korea were examined by chiral HPLC. The Chiralcel OD-H column, ChiralHyun-LE(S)-1 column and LUX-Cellulose-1 column were used as chiral stationary phases and the mixed eluent of hexane:isopropanol:acetic acid as 100:1:0.1 was used as a mobile phase with a flow rate of 1.0 mL/min. Each data was obtained from an average value of at least three different experiments for each sample and the relative standard deviation of them appeared very small. The average optical purity values obtained from three different chiral columns were very similar and the total average optical purity value (99.32%) of nineteen commercialized naproxens used in this study were larger than those of three years ago (98.17%).