• Title/Summary/Keyword: Position control device

Search Result 404, Processing Time 0.024 seconds

The Indoor Position Detection Method using a Single Camera and a Parabolic Mirror (볼록 거울 및 단일 카메라를 이용한 실내에서의 전 방향 위치 검출 방법)

  • Kim, Jee-Hong;Kim, Hee-Sun;Lee, Chang-Goo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.2
    • /
    • pp.161-167
    • /
    • 2008
  • This article describes the methods of a decision of the location which user points to move by an optical device like a laser pointer and a moving to that location. Using a conic mirror and CCD camera sensor, a robot observes a spot of user wanted point among an initiative, computes the location and azimuth and moves to that position. This system offers the brief data to a processor with simple devices. In these reason, we can reduce the time of a calculation to process of images and find the target by user point for carrying a robot. User points a laser spot on a point to be moved so that this sensor system in the robot, detecting the laser spot point with a conic mirror, laid on the robot, showing a camera. The camera is attached on the robot upper body and fixed parallel to the ground and the conic mirror.

2D Finite Element Analysis of Double-side LPM (양측식 리니어 펄스 모터의 2차원 유한요소해석)

  • Lee, Dong-Ju;Lee, Eun-Woong;Kim, Sung-Hun;Kim, Il-Jung;Kim, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.760-762
    • /
    • 2000
  • Hybrid type LPM can be widely applied in the precise position controlled devic because precise linear motion can be directly obtained by the simple control circuit without backlash in the rotary-type stepping motor. Also, LPM can increase the Position resolution, which was limited by mechanical manufacturing limit and characteristic of magnetic material. using micro-step drive method to decrease the noise and vibration further. Especially, Double-side LPM may be replaced the solenoid as the valve driving device without difficulty and give full play to control the valve accurately. Hence, In this paper, magnetic circuit of double-side LPM was confirmed and static thrust force curve according to the relative displacement between stator and mover, was analyzed by the two dimensional finite element method. From this results, we can suppose the excitation current to be controlled optimally.

  • PDF

Optimal Design of a 6-DOF Parallel Mechanism using a Genetic Algorithm (유전 알고리즘을 이용한 6자유도 병렬기구의 최적화 설계)

  • Hwang, Youn-Kwon;Yoon, Jung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.560-567
    • /
    • 2007
  • The objective of this research is to optimize the designing parameters of the parallel manipulator with large orientation workspace at the boundary position of the constant orientation workspace (COW). The method uses a simple genetic algorithm(SGA) while considering three different kinematic performance indices: COW and the global conditioning index(GCI) to evaluate the mechanism's dexterity for translational motion of an end-effector, and orientation workspace of two angle of Euler angles to obtain the large rotation angle of an end-effector at the boundary position of COW. Total fifteen cases divided according to the combination of the sphere radius of COW and rotation angle of orientation workspace are studied, and to decide the best model in the total optimized cases, the fuzzy inference system is used for each case's results. An optimized model is selected as a best model, which shows better kinematic performances compared to the basis of the pre-existing model.

A Low Cost Drive System of Switched Reluctance Motor Using Reflective Type Photosensors (반사형 광센서를 사용한 저가형 SRM 구동시스템)

  • Kim, Se-Joo;Yoon, Yong-Ho;Jung, Gyun-Ha;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.63-68
    • /
    • 2004
  • Since rotor position information is necessary to drive the SRM, absolute-encoder, resolver and incremental-encoder is used to detect a poor position. But, it is not desirable to use a high priced encoder and high efficient microprocessor under the condition of the simple driving system when precision control is not demanded. In this paper, Only using the reflective type 2 photosensors replace the conventional opto interrupter and slotted disk, which not only remove a slotted disk section but drive 3-phase 6/4 SRM bidirectionally. Moreover, as control circuit only is composed of common analog device economy is maximized.

  • PDF

Installation Error Calibration by Using Levenberg-Marquardt Method on a Cubic Parallel Manipulator (Levenberg-Marquardt 방법을 이용한 육면형 병렬기구의 설치 오차 보정)

  • 임승룡;임현규;최우천;송재복;홍대희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.184-191
    • /
    • 2003
  • A parallel manipulator has high stiffness and all the joint errors on the device are not accumulated at the end -effector unlike a serial manipulator. These are the reasons why the parallel manipulator has been widely used in many fields of industry. In the parallel manipulator, it is very important to predict the exact pose of the end-effector when we want to control the end-effector motion. Installation errors have to be determined in order to predict and control the actual position and pose of the end-effector. This paper presents an algorithm to find the whole 36 joint error components with joint clearance errors and measurement errors considered, when a link length measurement sensor is used and data more than 36 times are acquired for 36 different configurations. A simulation test using this algorithm is performed with a Matlab program which uses the Levenberg-Marquardt method that is known to be efficient for non-linear optimization.

A New Device and Procedure for Kinematic Calibration of Parallel Manipulators

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1615-1620
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise. Intrinsic inaccuracies of the device can significantly deteriorate the calibration results. A measurement procedure is proposed and formulations of cost functions are discussed to prevent propagation of the inaccuracies to the calibration results.

  • PDF

Toward Transparent Virtual Coupling for Haptic Interaction during Contact Tasks (컨택트 작업 시 햅틱 인터렉션의 투명성 향상을 위한 Virtual Coupling 기법의 설계)

  • Kim, Myungsin;Lee, Dongjun
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.3
    • /
    • pp.186-196
    • /
    • 2013
  • Since its introduction (e.g., [4, 6]), virtual coupling technique has been de facto way to connect a haptic device with a virtual proxy for haptic rendering and control. However, because of the single dependence on spring-damper feedback action, this virtual coupling suffers from the degraded transparency particularly during contact tasks when large device/proxy-forces are involved. In this paper, we propose a novel virtual coupling technique, which, by utilizing passive decomposition, reduces device-proxy position deviation even during the contact tasks while also scaling down (or up) the apparent inertia of the coordinated device-proxy. By doing so, we can significantly improve transparency between multiple degree of freedom (possibly nonlinear) haptic device and virtual proxy. In other to use passive decomposition, disturbance observer of [3] is adopted to estimate human force with some dead-zone modification to avoid "winding-up" force estimation in the presence of device torque saturation. Some preliminary experimental results are also given to illustrate efficacy of the proposed technique.

Research of Active Transponder application as Ground Control Point in Synthetic Aperture Radar Images (SAR 영상 내에서 능동 트랜스폰더의 GCP 활용 여부에 관한 연구)

  • Jeong, Ho-Ryung;Oh, Tae-Bong;Park, Duk-Jong;Lee, Sun-Gu;Lim, Hyo-Suk
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.164-170
    • /
    • 2012
  • This paper presents that the comparison results of AT (Active Transponder) positions obtained from different measurements: the result of GPS device and evaluated position from the SAR (Synthetic Aperture Radar) image, and active transponders can be useful as GCPs(Ground Control Points) in SAR images. The X-band AT are installed on the wide-and-flat area to improve SCR(signal-to-clutter ration), and activated to represent impulse response function in order to operate as one point target in SAR images. Cosmo-SkyMed operating at X-band frequency are used to provide SAR images of AT. The comparison of AT position is performed by using the result of GPS device field measurement and AT SAR images. ENVI-SARscape S/W is used to evaluate AT position in the SAR images. From the comparison, it is shown that AT are useful as GCPs for SAR images.

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.

A study on the design and the application of an optical sun-position sensor (광학적 태양위치센서의 개발과 그 응용에 관한 연구)

  • 신현덕;고명삼
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.393-396
    • /
    • 1986
  • A Sun-Position Sensor using four phototransistors and shadow band device has been designed, and a Sun-Tracking System which tracks varying positions of the sun in elevation and azimuth axes has been built and its performance has been analyzed on the basis of indoor experiments and computer simulations. Two permanent-magnetic Step Motors (1.8.deg./step) for the main actuators and a CRC-800A kit with the Z-80CPU for the main controller have been selected to construct the Sun-Tracking System. It has been shown that the Sun-Position Sensor has about 0.5.deg. resolution and 25msec is required for the response of a single step input to reach its steady state.

  • PDF