Purpose: This study examined the effects of the directions of neck rotation position on the muscle activity and strength of the elbow flexor and extensor muscle. Methods: Forty-one healthy adults participated in this study. The subjects were asked to their elbow 90° flexion in three different neck rotations (neutral, ipsilateral, and contralateral) in the sitting position. The muscle activities of the biceps and triceps brachii muscle were measured using surface electromyography. And the muscle strength of the elbow flexor was measured using dynamometer. One way repeated measures ANOVA was used to compare the muscle activity and strength of the elbow flexor and extensor depending on the different neck turning directions. Results: There were significant differences between contralateral neck rotation and ipsilateral neck rotation, contralateral neck rotation and neutral position. But, there was no significant difference in the triceps brachii muscle activity in comparison with the neck rotation. There were significant differences between contralateral neck rotation and ipsilateral neck rotation, contralateral neck rotation and neutral position. Conclusion: To summarize this study, the elbow flexor and extensor muscle activity and strength was highest in the contralateral neck rotation position. In other words, it was possible to confirm the effect of Asymmetrical Tonic Neck Reflex in healthy adults whose primitive reflexes were inhibition, and head and neck positions should be considered during clinical evaluation and treatment.
Purpose : The purpose of present study was to investigate the effects of proprioceptive neuromuscular facilitation (PNF) lifting on contralateral leg muscle activities in a seated position. Methods : Twenty healthy subjects were recruited for this study. Lifting was performed from each of the three position. An surface electromyogram (EMG) was used to record the EMG activities from vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA), and gastrocnemius medialis (GM) in contralateral leg muscle. The data were analyzed using a repeated measures of one-way analysis of variance (ANOVA) with post-hoc Bonferroni's correction to determine the statistical significance. Results : The results of this study were summarized as follows: In comparison to the start position, percentage maximal voluntary isometric contraction (%MVIC) values of the VM, TA and GM demonstrated a significantly higher activities in the end position(p<.05). Conclusion : The result shows that contralateral leg muscles activities significantly more increase in the end position when PNF lifting was applied. Therefore, this study will be used to prove effect of indirect approach for the stability and strengthening in patients with leg impairments.
The purpose of this study was to compare the sleep characteristics between the prone and the supine position in healthy newborns. The 48 newborns were observed in the prone position and the supine position respectively on the 2nd day after birth. The data were collected from January to May, 1999. The state of a newborn was classified and categorized to 6 states (deep sleep. light sleep, drowsy, quiet alert, active alert, crying) by Barnard. The movements of eyes, face and extremities, pulse and arterial oxygen were observed and recorded continuously from the start of sleep after feeding until the time of being woken for the next feeding by a trained nurse The data was analyzed by using paired t-test. The results of this study were as follows; 1. There was no significant difference in the length of sleeping time between the prone and the supine position. 2. There was no significant difference in the length and frequencies of each states(deep sleep, light sleep, drowsy, quiet alert, active alert, crying) between the prone and the supine position But the frequency of light sleep in the supine position was significantly higher than that of the prone position. 3 There was no significant difference In the numbers or eyes movements between the prone and the supine sleep position. But the amount of facial and extremity movement in the supine position was significantly higher than those in the prone position 4. There was no significant difference in the arterial oxygen content between the prone and the supine sleep position. 5. There was no significant difference in the heart rates between the prone and the supine sleep position. The above results indicated that the newborns in the prone Position moved less and slept deeper than those in the supine position. though there was no difference in the length of sleep or arterial oxygen content between the prone and the supine sleep Position. But. Nurses and mothers should consider the relationship between the sleep Position and SIDS suggested by previous researches. The infant's 'awakening' during sleep is a normal process and rather valuable because it can provide an opportunity to promote a stronger relationship between mother and baby. So, It is suggested that the supine sleep position is better than the prone sleep position for infants.
The purpose of this study was to identify the effect of body positioning on $PaO_2$, $SpO_2$, systolic blood pressure, diastolic blood pressure, pulse, and respiration(above all defined physiologic index), of patients with unilateral lung disease. The subjects for this study were eleven patients admitted to I.C.U. of K.H.M.C. with a diagnosis of unilateral lung disease confirmed by chest X-ray and the attending doctor, from January 30th. to April 20th. 1999. A quasi-experimental repeated-measures cross-over design was used to compare three body positions(semi-Fowler's, lateral decubitus with good lung dependent, and lateral decubitus with diseased lung dependent). Each subject spent 30 minutes in semi-Fowler's position and 2 hours in good lung dependent position and diseased lung dependent position. Starting in the semi-Fowler's position, then in the lateral position with the good lung dependent or the diseased lung dependent as assigned in random order. Thirty minutes after each positioning, arterial blood sample was analyzed. Measurements of all physiologic index were recorded at the specified intervals(0, 30, 60 90, and 120 minutes) in good lung dependent and diseased lung dependent position. Statistical comparison of $PaO_2$ value was done using the Wilcoxon Signed Rank Test, and Multivariate repeated-measures analysis of variance was performed to analyse the within-subject effect of two dependent position for 2 hours on the five dependent variables: (1) $PaO_2$ (2) $SpO_2$ (3) systolic blood pressure (4) diastolic blood pressure (5) pulse. The results obtained were as follows: 1. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the diseased lung dependent position(Z=-2.8451, p=.002). 2. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the semi-Fowler's position (Z=-2.6673, p=.003). 3. The difference between the $PaO_2$ value in the semi-Fowler's position and the $PaO_2$ value in the diseased lung dependent position was not significant(Z=-1.2448, p=.10). 4. There were no statistically significance in the trends of physiologic index in the good lung dependent position and the diseased lung dependent position. From the results, it may be concluded that the good lung dependent position is the most effective position for patients with unilateral lung disease that improve oxygenation. Identification of positioning over time may be need further studies.
Journal of information and communication convergence engineering
/
v.9
no.6
/
pp.747-752
/
2011
The position detection of overlapping area in the interframe for image stitching using auto and cross correlation function (ACCF) and compounding one image with the stitching algorithm is presented in this paper. ACCF is used by autocorrelation to the featured area to extract the filter mask in the reference (previous) image and the comparing (current) image is used by crosscorrelation. The stitching is detected by the position of high correlation, and aligns and stitches the image in shifting the current image based on the moving vector. The ACCF technique results in a few computations and simplicity because the filter mask is given by the featuring block, and the position is enabled to detect a bit movement. Input image captured from CMOS is used to be compared with the performance between the ACCF and the window correlation. The results of ACCF show that there is no seam and distortion at the joint parts in the stitched image, and the detection performance of the moving vector is improved to 12% in comparison with the window correlation method.
International Journal of Internet, Broadcasting and Communication
/
v.12
no.4
/
pp.173-179
/
2020
In this study, we present the difference in thoracic reposition sense in young people (24.00 ±2.20 years old) with and without habitual slouched posture in two target positions of half flexion and half extension. People with habitual slouched posture (n = 20; 11 men and 9 women) and people without slouched posture (n = 20; 10 men and 10 women) were recruited from three universities. Thoracic spine (T-spine) repositioning errors were measured in two target positions (half flexion and half extension). People with habitual slouched posture showed significantly higher thoracic repositioning error in the extension target position than did people without slouched posture (P<0.05). There was no difference in repositioning error in the flexion target position between the two groups (P>0.05). In conclusion, people with habitual slouched posture show lower T-spine repositioning sense in extension than do people without slouched posture. A rehabilitation program to treat habitual slouched posture, such as postural correction education, should be implemented for individuals with decreased position sense of the T-spine.
E. coli methionyl-tRNA synthetase is one of the class I tRNA synthetases. The Tryptophane residue at the position 461 located in the C-terminal domain of the enzyme is a key amino acid for the interaction with the anticodon of $tRNA^{Met}$. W461 was replaced with other amino acids to determine the chemical requirement for the interaction with the anticodon of $tRNA^{Met}$. Saturation mutagenesis at the position 461 generated a total of 12 substitution mutants of methionyl-tRNA synthetase. All the mutants showed the same in vivo stability as the wild-type enzyme, suggesting that the amino acid substitutions did not cause severe conformational change of the protein The mutants containing tyrosine, phenylalanine, histidine and cysteine substitutions showed in vivo activity while all the other mutants did not. The comparison of the in vitro aminoacylation activities of these mutants showed that aromatic ring structure, Van der Waals volume and hydrogen bond potential of the amino acid residue at the position 461 are the major determinants for the interaction with the anticodon of $tRNA^{Met}$.
Transactions of the Korean Society of Mechanical Engineers A
/
v.26
no.2
/
pp.254-259
/
2002
A variable air-gap type system is widely used for inductive precision position measurement systems. This type transducer has high sensitivity but lacks a linear measurement range due to structural nonlinearity. Furthermore, as measurement range increases, linearity error is also increased. The alternative is a variable overlap-area type system. The sensitivity of this type is determined by the initial air-gap dimension, keeps the original value and does not deteriorate linearity in spite of the variations of the measuring range.
The frequency spectrum of the metallic closing sound and its loudness were measured by non invasive techniques in 66 patients. They had examined a total of 7 Carbomedics valve, 10 Duromedics valve, 11 St. Jude heart valve in mitral position and 8 Carbomedics, 10 Duromedics, 20 St. Jude heart valve prostheses functioning normally in aortic position. Statistical comparison of the loudness from sound produced by the three valves in each position, the following; The Carbomedics valve has the lowest average loudness, followed by the St. Jude medical valve, and finally the Edward Duromedics valve. And we analysis the changing factor of the loudness of valve sound, only the velocity of the flow through the valve influenced to the valve sound.
Journal of the Korean Society of Manufacturing Technology Engineers
/
v.19
no.5
/
pp.645-652
/
2010
For free motions, vibration suppression of single flexible manipulators has been one of the hottest research topics. However, for cooperative motions of multiple flexible manipulators, a little effort has been devoted for the vibration suppression control. So, the aim of this paper is to develop a hybrid force/position control and vibration suppression control scheme for multiple cooperation flexible manipulators handling a rigid object. In order to clarify the discussion, the motions of dual-arm experimental flexible manipulator are considered. Using the developed model, we control a robotic system with hybrid position/force control scheme. Finally, Experiments are performed, and a comparison of experimental results is given to clarify the validity of our control scheme.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.