• 제목/요약/키워드: Position Change

검색결과 2,641건 처리시간 0.031초

골격성 3급 부정교합자의 악교정 수술 후 설골 위치와 상기도 크기의 변화 (CHANGES OF THE HYOID BONE POSITION AND THE UPPER AIRWAY DIMENSION AFTER ORTHOGNATHIC SURGERY IN SKELETAL CLASS III PATIENTS)

  • 김지용;안제영;임재형;허종기;박광호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.27-34
    • /
    • 2006
  • After orthognathic surgery in skeletal class III patients, the hyoid bone position and the upper airway dimension could be changed due to mandibular setback. There has been many studies about airway dimension of the patients with skeletal class II malocclusion or obstructive sleep apnea. but not with skeletal class III. The purpose of this study was to examine the change of position of the hyoid bone and the consequent change of airway space as the result of retrusion of mandible after orthognathic surgery in skeletal Cl III malocclusion patients. It is also to apply this results in predicting, diagnosing and treating the subsequent obstructive sleep apnea. Forty patients who were diagnosed as skeletal Cl III maloccusion, received orthoganthic surgery of both jaws including mandibular setback, and were followed up post-operatively for more than 6 months were selected. There were 10 male patients 30 female patients. The preoperative and postoperative lateral cephalograms were traced and the distances and angles were measured. The nasopharyngeal space increased postoperatively while the oropharyngeal space decreased. Except for the change of oroparyngeal space, the changes in male patients were greater than female patients. The hyoid bone moved in the posterior-inferior direction, and the change was greater in males than in females. If the postoperative mandibular setback is great, then a significant decrease of airway space and posterior and inferior movement of the hyoid bone were observed. This can result in symptoms related to obstructive sleep apnea. This result should be considered in the diagnosis and treatment planning of orthognathic surgery patients.

디지털신호처리 칩과 마이크로 컨트롤러를 이용한 적응 양변위 되먹임 제어기의 구현 (Implementation of Adaptive Positive Popsition Feedback Controller Using DSP chip and Microcontroller)

  • 곽문규;김기영;방세윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.498-503
    • /
    • 2005
  • This paper is concerned with the implementation of adaptive positive position feedback controller using a digital signal processor and microcontroller The main advantage of the positive position feedback controller is that it can control a natural mode of interest by tuning the filter frequency of the positive position feedback controller to the natural frequency of the target mode. However, the positive position feedback controller loses its advantage when mistuned. In this paper, the fast fourier transform algorithm is implemented on the microcontroller whereas the positive position feedback controller is implemented on the digital signal processor. After calculating the frequency which affects the vibrations of structure most the result is transferred to the digital signal processor. The digital signal processor updates the information on the frequency to be controlled so that it can cope with both internal and external changes. The proposed scheme was installed and tested using a beam equipped with piezoceramic sensor and actuator. The experimental results show that the adaptive positive position feedback controller proposed in this paper can suppress vibrations even when the target structure undergoes structural change thus validating the approach.

  • PDF

브러시리스 직류 전동기 센서리스 드라이브의 성능 향상을 위한 새로운 회전자 위치 간접 검출 방식 (A novel indirect rotor position sensing method to improve the performance of sensorless drive for brushless DC motors)

  • 조현민;박정배;이광운;여형기;유지윤
    • 전력전자학회논문지
    • /
    • 제5권1호
    • /
    • pp.95-103
    • /
    • 2000
  • 본 논문에서는 브러시리스 직류 전동기용 센서리스 드라이브의 성능 향상을 위한 새로운 회전자 위치 간접 검출 방식을 제안한다. 단자 전압을 이용하는 기존의 회전자 위치 간접 검출 방식들은 전동기를 동기 모드로 운전시 과도한 전압이 인가되면 회전자 위치를 정확히 검출할 수 없기 때문에 센서리스 운전 모드로의 신속한 전환이 어렵다. 따라서 본 논문에서는 전동기를 동기 모드로 운전하는 경우, 과전압에 의한 단자 전압과 역기전력 파형의 관계를 분석하여 저속 운전 영역에서도 회전자 위치를 정확히 검출할 수 있는 새로운 간접 검출 방식을 제안한다. 또한 실험을 통하여 제안한 방식의 효용성을 입증한다.

  • PDF

공기역학적 성능 향상을 위한 플랩의 최적 위치 선정 (SELECTION OF THE OPTIMAL POSITION OF THE FLAP FOR THE IMPROVEMENT OF AERODYNAMIC PERFORMANCE)

  • 강형민;박영민;김철완;이창호
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.41-46
    • /
    • 2013
  • The selection of the optimal position of the flap was performed in order to improve the aerodynamic performance during the take-off and landing processes of aircraft. For this, the existing airfoils of the main wing and flap are selected as the baseline model and the lift coefficients (cl) according to angle of attacks (AOA) were calculated with the change of the position of flap airfoil. The objective function was defined as the consideration of the maximum cl, lift to drag ratio and cl at certain AOA. Then, at 121 experimental points within $20mm{\times}20mm$ domain, two dimensional flow simulations with Spalart-Allmaras turbulence model were performed concerning the AOA from 0 to 15 degree. If the optimal position was located at the domain boundary, the domain moved to the optimal position. These processes were iterated until the position was included in the inside of the domain. From these processes, the flow separation at low AOA was removed and cl increased linearly comparing with that of the baseline model.

퍼지추론을 이용한 무인잠수정의 하이브리드 항법 시스템 (A hybrid navigation system of underwater vehicles using fuzzy inferrence algorithm)

  • 이판묵;이종무;정성욱
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.170-179
    • /
    • 1997
  • This paper presents a hybrid navigation system for AUV to locate its position precisely in rough sea. The tracking system is composed of various sensors such as an inclinometer, a tri-axis magnetometer, a flow meter, and a super short baseline(SSBL) acoustic position tracking system. Due to the inaccuracy of the attitude sensors, the heading sensor and the flowmeter, the predicted position slowly drifts and the estimation error of position becomes larger. On the other hand, the measured position is liable to change abruptly due to the corrupted data of the SSBL system in the case of low signal to noise ratio or large ship motions. By introducing a sensor fusion technique with the position data of the SSBL system and those of the attitude heading flowmeter reference system (AHFRS), the hybrid navigation system updates the three-dimensional position robustly. A Kalman filter algorithm is derived on the basis of the error models for the flowmeter dynamics with the use of the external measurement from the SSBL. A failure detection algorithm decides the confidence degree of external measurement signals by using a fuzzy inference. Simulation is included to demonstrate the validity of the hybrid navigation system.

  • PDF

국소적 진동 적용이 주관절의 위치 감각과 최대악력에 미치는 영향 (Effect of Local Vibration on Elbow Joint in Position Sense and Maximal Grip Force)

  • 허광호;이현민;천송희;방현수;강종호;김진상
    • 대한물리의학회지
    • /
    • 제3권3호
    • /
    • pp.145-149
    • /
    • 2008
  • Purpose : The purpose of this study was evaluate the effects of vibration on joint position sense. Methods : The subjects were divided into vibration group(n=20) and control group(n=20). Vibration group was given local vibration on elbow joint for 15 minutes and control group was given resting 15 minutes by resting position. All subjects of each group were tested pre-post on maximal grip force and joint position sense. Results : Maximal grip force test and joint position sense test of vibration group was showed a significant difference between pre and post(p<0.05). Conclusion : There was a different change on maximal grip force and joint position sense.

  • PDF

Effect of Electrical Muscle Stimulation Belt for Abdominal Muscles Activation

  • Choi, Dayeong;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권4호
    • /
    • pp.444-449
    • /
    • 2021
  • Objective: The purpose of this study is to observe the change in the thickness of abdominal muscles when electrical muscle stimulation (EMS) is applied to the abdomen during rest and abdominal muscle exercise to investigate the effect of EMS applied to the abdomen on the superficial and deep muscles thickness. Design: Cross sectional design. Methods: Twenty healthy subjects participated in this study. Subjects were performed resting position, resting position with EMS, curl-up and curl-up with EMS. The electrode of the EMS belt is attached to the abdominal wall between the 12th rib and iliac crest. The thickness of abdominal muscles including rectus abdominis (RA), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were captured in each position by ultrasound image during expiration. All subjects were performed four positions randomly. Data were analyzed using repeated ANOVA with the level of significance set at 𝛼=0.05. Results: The muscle thickness of RA, EO, IO and TrA were significantly different at each position (p<0.05). The thickness of all abdominal muscles increased significantly when curl-up than curl-up with EMS. Both RA and EO thickness were significantly increased at resting position than resting position and EMS were combined(p<0.05). But IO and TrA thickness were decreased at resting position when EMS were combined. Conclusions: The results suggest that EMS activates superficial abdominal muscles RA and EO. Therefore, abdominal strengthening exercise combined EMS can activate abdominal muscles and can be applied to various patients and rehabilitation in clinical practice.

뇌졸중 환자의 자세변화에 따른 폐기능비교 (Comparison of Posture on Respiratory Function in the Stroke Patients according to Changes of Position)

  • 서교철;이성은;이전형;김경
    • 대한물리의학회지
    • /
    • 제6권4호
    • /
    • pp.381-389
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the respiratory function in the different body position of the stroke patients. Methods : Twenty patients with stroke patients group(M:12, F:8) and twenty control group(M:12, F:8) were participated in experiment. Strokes patients group and control group were assessed according to position changes(supine position, $45^{\circ}$ sitting position, $90^{\circ}$ sitting position) using pulmonary function(vital capacity, inspiratory capacity, tidal volume, expiratory reserve volume, inspiratory reserve volume). Results : These findings suggest that supine position in stroke group and control group were significant difference in IC, VC, IRV, ERV(p<.05). $45^{\circ}$ lean sitting position in stroke group and control group were significant difference in IC, VC, ERV(p<.05). 90 sitting position in stroke group and control group were significant difference in VC, IRV, ERV(p<.05). In comparison of two groups, strokes group was more low pulmonary function than normal group. Conclusion : This study showed pulmonary function was more high normal groups than stroke groups. And $90^{\circ}$ sitting position was high pulmonary function than supine position, $45^{\circ}$ lean sitting position. Thus it indicates that the functions will be suggest the objective data of patients with strokes for respiratory function.

u-WBAN 기반의 센서를 이용한 자세교정 시스템 설계 및 구현 (The Design and Implementation of the Position Calibration System Using Sensor on u-WBAN)

  • 문승진;박윤성
    • 한국지능시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.304-310
    • /
    • 2010
  • 현대를 살아가는 현대인들이 경험하는 만성통증 및 디스크는 성인의 80% 이상이 경험하는 흔한 질병이다. 이러한 질환들 중 교통사고, 추락 등 물리적인 충격에 의한 발생율은 10%정도이며 대부분이 습관적으로 부적합한 자세를 취하게 되어 특정 부위에 지속적인 스트레스가 쌓여 발생하게 된다. 이처럼 부적합한 자세가 오랫동안 이어져 질환의 원인이 되는 것을 알면서도 고쳐지지 않는 이유는 지속적인 반복을 통한 습관화로 인하여 부적합한 자세를 바로 인지하지 못함으로써 바르게 교정하지 못하고 지속되어지기 때문이다. 따라서 본 시스템은 자세를 측정할 수 있는 센서들을 사용자에게 부착 후 사용자의 자세에 따른 데이터를 수집하여 정확한 자세를 측정하고 자세추정알고리즘을 이용하여 해당 자세의 적합여부를 추정한다. 사용자가 부적합한 자세를 지속적으로 취할 경우 이를 인지할 수 있도록 한다. 그리고 적합한 자세로 변경하도록 유도하여 부적합한 자세의 습관화를 방지하는데 목적을 두고 있다. 또한 부적합한 자세의 원인을 분석 후 제거하여 적합한 자세를 취하는데 보조자의 기능을 수행 한다. 정확한 측정을 통한 반복적인 인지 학습을 통해 올바른 자세를 습관화 한다면 성장기 어린이와 만성 질환자에게 많은 도움을 줄 것으로 생각 된다.

20대 남성 비만인의 자세에 따른 가슴우리 확장과 폐기능 특성분석 (Analysis of the Chest Expansion and Pulmonary Function in the 20s men Obesity according to Position Change)

  • 김현애;서교철;임상완;김희탁;김경
    • 대한물리의학회지
    • /
    • 제6권3호
    • /
    • pp.247-256
    • /
    • 2011
  • Purpose : The purpose of this study were to determine whether changes of position might effect the chest expansion and pulmonary function of the 20s men obesity. Methods : Thirty subjects with obesity(M:30, % fat>25.0) and thirty normal subjects(M:30, % fat<24.9) were participated in experiment. Subjects were assessed according to position changes(supine position, $45^{\circ}$ lean sitting position, $90^{\circ}$ sitting position) using chest length(chest length for resting, chest expansion) and pulmonary function (Tidal volume, Inspiratory capacity, Vital capacity, Inspiratory reserve volume, Expiratory reserve volume) by the CardioTouch 3000S(BIONET, USA). Repeated measure ANOVA was used to compare each region data of chest length and pulmonary function according to changes of position with obesity and normal subjects. Results : These findings suggest that the obesity can be appear to low chest expansion and pulmonary function than normal subjects on position method. In comparison of three experimental position, supine position was more low. Conclusion : This study showed position of the obesity appear low chest expansion and function of pulmonary volume than normal subjects, and thus it indicates that the pulmonary function of the obesity will be suggest objective respiratory data through the exercise program.