• Title/Summary/Keyword: Portable hydrogen application

Search Result 7, Processing Time 0.027 seconds

A Performance Study of Portable Hydrogen Storage Tank (휴대용 수소 저장체 성능 특성 연구)

  • Park, Joon-Ho;Hwang, Yong-Sheen;Jee, Sang-Hoon;Kim, Sung-Han;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.315-318
    • /
    • 2009
  • Hydrogen is the ideal candidate as an alternative energy carrier, so many hydrogen storage methods are investigated. The hydrogen storage method using metal hydride is good candidate as energy sources for portable devices because hydrogen-storage as metal hydride shows large volumetric storage density. In this study, we investigated the variations of hydrogen charging/discharging performance of metal hydride tanks at different temperature conditions. We charged metal hydride tanks with hydrogen in low temperature because of the exothermic reactions of hydrogen absorption while we discharged in high temperature to provide sufficient heat because of the endothermic reactions of desorption. In addition, we investigated the difference of hydrogen charging/discharging performance between two tanks having different sizes.

  • PDF

Electrochemical Oxidation of Hydrazine in Membraneless Fuel Cells

  • Durga, S.;Ponmani, K.;Kiruthika, S.;Muthukumaran, B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.73-81
    • /
    • 2014
  • This paper describes the continuous flow operation of membraneless sodium perborate fuel cell using acid/alkaline bipolar electrolyte. Here, hydrazine is used as a fuel and sodium perborate is used as an oxidant under Alkaline-acid media configuration. Sodium perborate affords hydrogen peroxide in aqueous medium. In our operation, the laminar flow based microfluidic membranleless fuel cell achieved a maximum power density of $27.2mW\;cm^{-2}$ when using alkaline hydrazine as the anolyte and acidic perborate as the catholyte at room temperature with a fuel mixture flow rate of $0.3mL\;min^{-1}$. The simple planar structured membraneless sodium perborate fuel cell enables high design flexibility and easy integration of the microscale fuel cell into actual microfluidic systems and portable power applications.

Influence of the cathode catalyst layer thickness on the behaviour of an air breathing PEM fuel cell

  • Ferreira-Aparicio, Paloma;Chaparro, Antonio M.
    • Advances in Energy Research
    • /
    • v.2 no.2
    • /
    • pp.73-84
    • /
    • 2014
  • Fuel cells of proton exchange membrane type (PEMFC) working with hydrogen in the anode and ambient air in the cathode ('air breathing') have been prepared and characterized. The cells have been studied with variable thickness of the cathode catalyst layer ($L_{CL}$), maintaining constant the platinum and ionomer loads. Polarization curves and electrochemical active area measurements have been carried out. The polarization curves are analyzed in terms of a model for a flooded passive air breathing cathode. The analysis shows that $L_{CL}$ affects to electrochemical kinetics and mass transport processes inside the electrode, as reflected by two parameters of the polarization curves: the Tafel slope and the internal resistance. The observed decrease in Tafel slope with decreasing $L_{CL}$ shows improvements in the oxygen reduction kinetics which we attribute to changes in the catalyst layer structure. A decrease in the internal resistance with $L_{CL}$ is attributed to lower protonic resistance of thinner catalyst layers, although the observed decrease is lower than expected probably because the electronic conduction starts to be hindered by more hydrophilic character and thicker ionomer film.

A Study on the Optimum Design for LTCC Micro-Reformer: (Performance Evaluation of Various Flow Channel Structures ('LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구: (다양한 채널구조에 따른 성능변화 고찰)')

  • Chung Chan-Hwa;Oh Jeong-Hoon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.551-552
    • /
    • 2006
  • The miniature fuel cells have emerged as a promising power source for applications such as cellular phones, small digital devices, and autonomous sensors to embedded monitors or to micro-electro mechanical system (MEMS) devices. Several chemicals run candidate at a fuel in those systems, such as hydrogen. methanol, ethanol, acetic acid, and di-methyl ether (DME). Among them, hydrogen shows most efficient fuel performance. However, there are some difficulties in practical application for portable power sources. Therefore, more recently, there have been many efforts for development of micro-reformer to operate highly efficient micro fuel cells with liquid fuels such as methanol, ethanol, and DME In our experiments, we have integrated a micro-fuel processor system using low temperature co-fired ceramics (LTCC) materials. Our integrated micro-fuel processor system is containing embedded heaters, cavities, and 3D structures of micro- channels within LTCC layers for embedding catalysts (cf. Figs. 1 and 2). In the micro-channels of LTCC, we have loaded $CuO/ZnO/Al_2O_3$ catalysts using several different coating methods such as powder packing or spraying, dipping, and washing of catalyst slurry.

  • PDF

Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation (5kW 급 주택용 고분자 연료전지 시스템)

  • Yang, Tae-Hyun;Park, Gu-Gon;Yoon, Young-Gi;Lee, Won-Yong;Yoon, Wang-Lai;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

ANALYSIS OF FLUIDIC BEAD CUBE EMBEDDED PORTABLE CMOS SENSING SYSTEM FOR IMMUNO REACTION MONITORING (유체소자가 집적화된 면역검사용 휴대용 CMOS 바이오칩의 분석)

  • Jeong, Yong-Won;Park, Se-Wan;Kim, Jin-Seok;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.755-758
    • /
    • 2005
  • This paper describes the novel immunoassay sensing system for a portable clinical diagnosis system. It consists of a bead cage reactor and a CMOS integrated biosensor. It showed the simple and easy antibody coating method on beads by flow-through avidin biotin complex technology in a microfluidic device. It showed just 90 nL sample consumption and good result for the application of alpha feto protein. The bead cage reactor has the role of the antibody coating, antigen binding and enzyme linking for the electrochemical sensing method. The CMOS biosensor consists of ISFET (ion selective field effect transistor) biosensor and temperature sensor for detecting pH that is the byproduct of enzyme reaction. The sensitivity is 8 $kHz/^{\circ}C$ in a temperature sensor and 33 mV/pH in a pH sensor. After filling the 15 um polystyrene beads in bead cage, antibody flowed and reacted to beads. Subsequently, the biotinylated antigen flowed and bound to the antibody and GOD (glucose oxidase)-avidin conjugate flowed and reacted to the biotin of the biotinylated antigen. After this reaction process, glucose solution flowed and reacted to the GOD on beads. The hydrogen was generated by glucose-GOD reaction. And it was detected by the pH sensor.

  • PDF

A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident (화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구)

  • Oh, Joo-Yeon;Lee, Tae Wook;Cho, Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1817-1826
    • /
    • 2022
  • After the hydrogen fluoride leak in Gumi in 2012, the government has been systemizing the disaster management system, such as responding to and managing chemical accidents. In particular, the Ministry of the Interior and Safety (MOIS) is in charge of evacuation of residents following chemical accidents based on the Framework Act on Management of Disaster and Safety. In this study, an application plan was presented to support and utilize the decision-making support for evacuation of residents after a chemical accident using the chemical accident investigation equipment of the National Disaster Management Research Institute (NDMI). In the equipment operation system for scientific information collection due to chemical accidents, the roles and purpose of use of long/short distance measurement equipment were presented according to regular and emergency situations. Using the data acquired through long/short distance measurement equipment, it can be used as basic data for resident evacuation decision-making by monitoring whether chemicals are detected in an emergency and managing data on detected substances by company in a regular situation. As a result of measuring chemical substances in order to verify on-site usability by equipment only for the regular operation system, it was confirmed that real-time detection of chemical substances is possible with long distance measuring equipment. In addition, it was confirmed that it was necessary to check the measurable distance and range of the equipment in the future. In the case of short distance measurement equipment, hydrocarbon-based substances were mainly detected, and it was confirmed that it was measured at a higher level in Ulsan-Mipo National Industrial Complex than in Onsan National Industrial Complex. It is expected that it can be used as basic data to support decision-making in the event of chemical accidents through continuous data construction in the future.