• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.026 seconds

Measures to Improve the Efficiency of the Portable Air Quality Measurement System

  • CHOI, Jong-Sun;CHO, Dong-Myung;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.27-41
    • /
    • 2022
  • Purpose: In this study, pollutants generated in industrial areas were measured using a Portable Air Quality Measurement System(PAQMS). This study intends to examine in detail improvement measures and operational capabilities to operate a more efficient PAQMS. Research design, data and methodology: This study compares and analyzes the measurement values of the PAQMS and the measurement values of the national air quality measurement network. It is intended to develop a PAQMS corresponding to the data of the national measurement network by minimizing the errors that occur during comparative measurement and analysis and supplementing and improving the problems that occur during the current equipment calibration. Results: A PAQMS is an essential equipment for faster and more accurate measurement and analysis of pollutants in case of untimely measurement and civil complaints due to Micro Climate(local weather and environmental influences). Currently, there are many atmospheric measurement equipment in Korea, but only equipment for each item is produced and sold. Currently, these devices on the market must satisfy various conditions such as stable power, temperature, and humidity to calculate accurate measurement values. Conclusions: Therefore, there is no equipment that satisfies the conditions for performing detailed measurement in the field where accurate measurement is required. In this study, these field work conditions and contents for stable measurement were mentioned in the text.

A Study on the Scattered Dose in Portable Chest Radiography (portable 흉부촬영시 공간산란선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Hwan-Hyung
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

Development of Portable Dissolved Gas Analyzer Using photoacoustic spectroscopy (광음향 분광법을 이용한 휴대용 유중가스분석장치 개발)

  • Kim, Choon-Dong;Kim, Chol-Gyu;Park, Sh-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2431-2438
    • /
    • 2013
  • The paper presents a procedure for how to development and theoretical review on Dissolved Gas Analyzer. the information of abnormal thermal stress on electrical power equipment by testing the gas is validated to easy by the gas analyzer presented in the paper. the analyzed information is used to evaluate the stability of electrical power equipment. the existing and selling DGA(dissolved gas analyzer) is so expensive and vast that all DGA product comes from foreign country. The objective of the paper is to prove that PAS(photoacoustic spectroscopy) based on a compact portable DGA solve the fixed type of DGA in order to eliminate the occurring issue directly or indirectly. the proposed DGA is easy to handle, and this can also analysis in real time for testing electrical power equipment. By applying the proposed portable, DGA be utilized in the currently electrical power equipment that are being implemented to reduce cycle of analysis of dissolved gas, it can contribute to improving safety by providing the agility of the evaluation of degradation.

Development of Portable Atmospheric Environment Measurement System using Low Power Wireless Communication

  • Chae, Soohyeon;Kim, Hack-Yoon;Gim, Jangwon
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.1
    • /
    • pp.99-109
    • /
    • 2020
  • As environmental pollution has become severe due to the rapid increase in pollutant generation in the air, measurement, collection, and analysis of atmospheric environment information plays an important role. However, it is difficult to measure the high-resolution and real-time atmospheric environment of the cities and tourist spots with high population mobility only by measuring equipment of stationary measuring stations. Therefore, this paper proposes a portable atmospheric environment measurement system for real-time measurement and monitoring of atmospheric environment information. The proposed system is a portable client with a low-power wireless communication method. It is possible to reliably transmit and receive the measured data through a multi-threaded server to monitor the trend of pollutants in the air in real-time.

An Acoustic Analysis of Noise Environments during Mobile Device Usage

  • Park, Hyung Woo
    • International journal of advanced smart convergence
    • /
    • v.6 no.2
    • /
    • pp.16-23
    • /
    • 2017
  • In contemporary modern society, people are constantly exposed to many kinds of noise, such as that from machinery, aircraft, construction sites, or road traffic. Noise is considered one of the most indispensable and influential parts of human life. This study investigates the acoustic characteristics of noise transfer from external sources to the human ear. For this study, we measured and analyzed various types of noise environments, installed monitoring speakers in a semi-anechoic room, and conducted intentional noise-filled experiments. In this environment, the size of the sounds generated by use of a portable device was also measured and the SNR (signal to noise ratio) calculated to study the influence of the noise. As sound is transmitted to the ear and the human body, it affects not only auditory damage but also other parts of the body. In this paper, we propose a proper SNR for noise emitted by portable IT equipment to prevent hearing loss when IT equipment is used.

The Necessary of Portable X-ray Equipment for Emergency Medical Service System and Sports Injures (응급의료체계와 스포츠손상에서 휴대용 X-ray 장치의 도입 필요성)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Jo, Jeanman
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.189-197
    • /
    • 2004
  • The fate of a emergency patient is decided upon the extent of first aid in one hour after accident. Suitable diagnosis and treatment can raise the possibility of patient's life and reduce the recuperation time. We surveys papers which were The Korean Society Of Sports Medicine(1993-2004 yeas 405papers)and The Korean Society Of Emergency Medicine (1990-2004 yeas 797 papers). This paper got the following results through analyses of problems in emergency medical service system and of injures from sports. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment (이동형 치과 X선 발생장치의 공간선량 분포)

  • Han, Gyeong-Soon;Ahn, Sung-Min
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.254-258
    • /
    • 2015
  • To compare the stationary dental X-ray generator and the portable dental X-ray generator and to understand spatial radiation dose depended on locations by measuring spatial radiation dose of the portable dental X-ray generator. The researchers used an Ionization chamber to measure spatial radiation dose which was generated while applying X-ray radiation to real bone skull phantom with both portable and stationary dental X-ray generator. There were 4 measurement locations which were immediate anterior, right, left and posterior. Distance of measurement was 50 cm in every location and the recorded result is an average of two applications of X-ray radiation to the maxillary molar area under the condition of 70 kVp, 3 mA, 0.1 sec. Average spatial radiation dose of portable X-ray generator was $37.51{\mu}Sv$, much higher than that of stationary X-ray generator which was $10.77{\mu}Sv$ (p<0.001). The result of the spatial radiation dose of the portable X-ray generator showed a huge difference depending on types of units which varied from $17.77{\mu}Sv$ to $68.90{\mu}Sv$ (p<0.05), also depending on the measurement location, immediate anterior resulted in the highest radiation dose of $54.14{\mu}Sv$ and immediate right was the lowest of $13.60{\mu}Sv$. Immediate left and posterior, however, resulted in similar radiation dose which were $42.12{\mu}Sv$, $40.18{\mu}Sv$ (p<0.01). With this result, we claim that usage of portable dental X-ray generator should be restricted to patients who can't move and exposure to radiation should be minimized by wearing lead-apron.

Fundamental Study for Reformation of Safety Standard about Portable Butane Gas Range (이동식 부탄 연소기의 안전기준 개정을 위한 기초 연구)

  • Kim, Sooik;Keum, Kuk Bin;Yu, Byeonghun;Lee, Chang-Eon;Kim, Young-Gu
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.4
    • /
    • pp.35-41
    • /
    • 2014
  • The experiment was conducted to measure temperature and pressure around operating portable butane gas ranges with oversized cookwares. In this experiment, portable butane gas range with different safety equipment and two kinds of oversized cookware, each of which is made of aluminum alloy and rock, was used. As a result, temperature of the bottom of the butane and the pressure of butane barrel tend to aligned with each other. Through this result, it is reasonable that a safety criteria can be decided based on the temperature of the bottom of butane. Especially, portable butane gas ranges are safely conducted under the condition of the temperature is under 50 degree and pressure is under 500 kPa, respectively, at the bottom of the butane barrel.

The Management of Chronic Wound with Modified Portable Negative Pressure Therapy (만성 창상의 치료에서 이동식 음압요법의 신고안)

  • Kim, Jee Soo;Yoon, In Mo;Yoo, Jung Seok
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.223-228
    • /
    • 2008
  • Purpose: V.A.C. is a new concept which is closed dressing with negative pressure to promote wound healing. It has been widely used as the treatment of chronic and acute wounds such as pressure sores, burns, stasis ulcers, and other complicated wounds. However It has disadvantages such as high cost and the need of specific equipment. In this article, we described new method to overcome these disadvantages. Methods: We made newly innovated equipment with 50 cc syringe and spring to create negative pressure. From May 2006 to May 2007, we applied it to two patients with chronic wound. Results: The treatment period was 5 weeks for one case and 3 weeks for the other case. Both patients were healed completely without admission and wound healing was accelerated. During follow-ups, there were no complications. The mean cost for single dressing was 9,590 won. Conclusion: Modified portable negative therapy using newly innovated equipment could accelerate wound healing better than conventional dressing. It lowers the number of dressings, saves cost of treatment, and enables treatment as outpatient basis.