• Title/Summary/Keyword: Portable System

Search Result 1,358, Processing Time 0.028 seconds

A Study on Speech Synthesizer Using Distributed System (분산형 시스템을 적용한 음성합성에 관한 연구)

  • Kim, Jin-Woo;Min, So-Yeon;Na, Deok-Su;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.209-215
    • /
    • 2010
  • Recently portable terminal is received attention by wireless networks and mass capacity ROM. In this result, TTS(Text to Speech) system is inserted to portable terminal. Nevertheless high quality synthesis is difficult in portable terminal, users need high quality synthesis. In this paper, we proposed Distributed TTS (DTTS) that was composed of server and terminal. The DTTS on corpus based speech synthesis can be high quality synthesis. Synthesis system in server that generate optimized speech concatenation information after database search and transmit terminal. Synthesis system in terminal make high quality speech synthesis as low computation using transmitted speech concatenation information from server. The proposed method that can be reducing complexity, smaller power consumption and efficient maintenance.

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Development of a 200 W Portable PEM Fuel Cell System (200 W급 휴대용 고분자 전해질막 연료전지 시스템 개발)

  • Han, Hun-Sik;Kim, Yun-Ho;Cho, Chang-Hwan;Kim, Seo-Young;Hyun, Jae-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • A 200 W portable polymer electrolyte membrane fuel cell (PEMFC) system is developed. The PEMFC system consists of an air-cooled fuel cell stack module, a fuel supply subsystem, a power management subsystem, and a control electronics subsystem. The control logic is designed for the stable system operation. The system-level performance evaluation discloses that the present PEMFC system provides a rated power output of 200.5 W at 13.4 V with the maximum balance-of-plant (BOP) efficiency of 72%, and maximum system efficiency based on lower heating value (LHV) is 37% at 120.7 W system power output.

Repeatability and Appropriate Predicted Value of Portable Spirometry on Korean Adults (휴대용 폐기능 검사기의 재현성과 기대치에 관한 연구)

  • Choi, Jun-Yong;Jung, Hee-Jae;Lee, Kun-Young;Jeong, Seung-Yeon;Hwang, Joon-Ho;Rhee, Hyung-Koo;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.587-595
    • /
    • 2005
  • Objectives : The object of this study was to evaluate repeatability of portable spirometry and to determine an appropriate equation for predicted value. Materials and Methods : The subjects were 76 men and 45 women recruited from among Kyunghee University oriental medical students. Portable spirometry was performed via the procedure recommended in ATS guidelines. Repeatability of spirometry was checked against ATS repeatability standards and NHLEP QC grade. Percentage of predicted value of non-smokers was calculated through a Caucasian population-based regression equation(by Morris et al.) and Korean population based regression equation(by Kim et al.). These were compared. Result : 91.7% of subjects matched repeatability standards of ATS and 95% of subjects got interpretable NHLEP QC grades of A, B, and C. Mean percentage of predicted value by Morris et al. were as follows: Mean of FVC% was 90.86, FEV1% was 96.66, FEV1/FVC% was 107.48. Mean percentage of predicted value by Kim et al. were as follows. Mean FVC% was 92.38, FEV1% was 89.77, FEV1/FVC% was 96.95. Conclusions : Results of this study show that more than 90% of subjects meet repeatability criteria. This supports a role for the portable spirometer as a primary oriental medical office tool. Further, results are a verify that they Korean population-based predicted value equation is a more appropriate standard than the Caucasian population-based one, but a still more accurate standard is needed for the Korean adult population.

  • PDF

A Comparison of the Multipath Error Property In Wireless Location of CDMA and OFDM (CDMA 및 OFDM 기반 무선측위의 다중경로오차 특성 비교분석)

  • Bang Hye-Jung;Lee Jang-Gyu;Jee Gyu-In;Kim Jin-Won;Jung Hee;Hyun Moon-Pil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.989-995
    • /
    • 2006
  • This paper shows that the OFDM(Orthogonal Frequency Division Multiplex) system is robust to multipath than CDMA (Code Division Multiple Access) system and it has a strong possibility to be utilized as a supplementing wireless location system for the forthcoming portable internet network. The OFDM system based on IEEE 802.16e is a wireless TDD (Time Division Duplex) OFDMA (Orthogonal Frequency Division Multiple Access) system providing portable internet services in 2.3 GHz frequency band and is scheduled in service in Korea starting in 2006. In this paper, multipath error is calculated using a two-ray model and compared with that of a CDMA system which is following IS-95. The OFDM system shows a maximum multipath error of 3 m while a CDMA system shows a maximum multipath error of 61 m. For this simulation, an early-late technique is used. This technique is usually used to match synchronization of signal in DLL(Delay Lock Loop).

ANALYTICAL APPLICATIONS OF NEW PORTABLE NEAR INFRARED (NIR) SPECTROMETER SYSTEM

  • Ahn, Jhii-Weon;Kang, Na-Roo;Lim, Hung-Rang;Lee, Jung-Hun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1122-1122
    • /
    • 2001
  • A compact and handhold near infrared (NIR) system using microspectrometer was developed. This system was suitable not only in the laboratory, but also in the field or in the process. This system was first applied for classification of geographical origin of herbal medicine such as ginseng and sesame. To identify the origin of ginseng on site, the portable NIR system is more suitable for real field application. For this study, using the compact NIR system, soft independent modeling of class analogies (SIMCA) with 1100-1750 nm NIR spectra was utilized for classification of geographical origin (Korea and China) of both ginseng and sesame. The accuracy of results is more than 90%. Quantitative analysis for petroleum such as toluene, benzene, tri-methyl benzene, and ethyl benzene was performed with partial least squares (PLS) regression with NIR 1100-1750 nm spectra. This study showed that the NIR method and gas chromatography (GC), which is a standard method, have good correlations. Furthermore, the ash content of Cornu Cervi Parvum was analyzed and the accuracy was confirmed by the developed compact NIR system.

  • PDF

A Portable IoT-cloud ECG Monitoring System for Healthcare

  • Qtaish, Amjad;Al-Shrouf, Anwar
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.269-275
    • /
    • 2022
  • Public healthcare has recently become an issue of great importance due to the exponential growth in the human population, the increase in medical expenses, and the COVID-19 pandemic. Speed is one of the crucial factors in saving life, particularly in case of heart attack. Therefore, a healthcare device is needed to continuously monitor and follow up heart health conditions remotely without the need for the patient to attend a medical center. Therefore, this paper proposes a portable electrocardiogram (ECG) monitoring system to improve healthcare for heart attack patients in both home and ambulance settings. The proposed system receives the ECG signals of the patient and sends the ECG values to a MySQL database on the IoT-cloud via Wi-Fi. The signals are displayed as an ECG data chart on a webpage that can be accessed by the patient's doctor based on the HTTP protocol that is employed in the IoT-cloud. The proposed system detects the ECG data of the patient to calculate the total number of heartbeats, number of normal heartbeats, and the number of abnormal heartbeats, which can help the doctor to evaluate the health status of the patient and decide on a suitable medical intervention. This system therefore has the potential to save time and life, but also cost. This paper highlights the five main advantages of the proposed ECG monitoring system and makes some recommendations to develop the system further.

Data Evaluation Methods for Real Driving Emissions using Portable Emissions Measurement System(PEMS) (PEMS를 이용한 실제도로 주행 배출가스 측정 데이터 분석방법)

  • Kwon, Seokjoo;Kwon, Sangil;Lee, Jongtae;Oak, Seonil;Seo, Youngho;Park, Sungwook;Chon, Mun Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.965-973
    • /
    • 2015
  • Recently, an emission test procedure using a portable emissions measurement system(PEMS) has received much attention as an effective means of controlling real driving emissions from light-duty diesel vehicles. The PEMS-based test procedure will be implemented from 2017 in Europe and Korea as a complementary test procedure for certification and regulation. In the present study, on-road NOx emissions were measured for four kinds of Euro 5 Korean light-duty diesel vehicles under real driving conditions, including urban, rural, and motorway test routes. The real driving emission characteristics were evaluated using both a moving averaging window(MAW) and the weighted emission method(WEM). The evaluated NOx emission results (under real driving conditions) from the MAW and WEM showed similar tendencies for the test vehicles and routes, while exceeding the certification emission limit by 1.8~8.5 and 2.0~10.6 times, respectively.

Development of a Portable Digital Electrocardiograph(ECG) measurable with Gel-less Metal Electrodes (젤리스 금속 전극으로 측정가능한 휴대용 디지털 심전도계의 개발)

  • Nam, Young-Jin;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1903-1907
    • /
    • 2013
  • Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.