• Title/Summary/Keyword: Portable System

Search Result 1,358, Processing Time 0.029 seconds

A Development of Portable Bioelectric Signal Measurement System for Industrial Workers' Safety (근로자 안전을 위한 휴대용 생리모니터 시스템 개발)

  • 장준근;허웅;변미경;한상휘;김형태;김형조;김정국
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.241-245
    • /
    • 2004
  • In this paper, we implement a portable bioelectric signal measurement system for the safety of industrial workers. The developed system consists of two parts: the one is boielectric signal measurement unit and the other is signal analyzer system with PDA. The former includes signal processing part, A/D convertor, and 8051 based microprocessor, the latter includes software for signal analysis and display. The developed system detects industrial worker's ECG and displays and stores it to PDA. The ECG data in PDA can be transmitted to PC located in a distance, allowing a doctor to review the ECG and make a treatment decision. A doctor analyzes the ECG data and gives medical treatment to industrial worker.

  • PDF

Development of Portable Cadiovascular Signal Analysis System (휴대형 심혈관 신호해석장치의 개발)

  • Lee, D.J.;Lee, J.W.;Kim, H.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.663-665
    • /
    • 1998
  • The purpose of this paper is development of portable cardiovascular signal processing device. Beat-to-beat fluctuation in heart rate, respiration, and blood pressure have been known to be meditated by autonomic nervous system activities convergent on various effector organs. This system consists of data acquisition module, main data processing module and graphic LCD module. The data acquisition module is developed for data aquisition, data multiplexing and interfacing with main data processing system. And, main data processing module is developed for data storing, data processing and interfacing with graphic LCD module. The main processing system is based on 32-bit microprocessor.

  • PDF

Development of Radiation Detector with Intensifying Screen (증감지를 이용한 방사선검출기 개발)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.859-863
    • /
    • 2023
  • In this study, simple and portable radiation detection system using X-ray intensifying screen, optical sensor and micro-controller unit for education was proposed. The system was simply composed of detection unit consisting of an optical sensor and intensifying screen, micro-controller unit, and was designed to be suitable for portable. Radiation was measured using developed detection system and absorbed dose dosimeter with changing tube voltage from 50 to 100 kVp. The tube current and SDD were fixed on 100 mAs and 100 cm, and dose were measured repeated ten times at each tube voltage. The response and linearity of the detection system were confirmed using the measured values. It was confirmed that the comparison measurement results of the detection system and absorbed dose dosimeter showed a high correlation(r : 0.998, p<.001). In this results, the feasibility of the detection system with intensifying screen and micro-controller unit based was confirmed, and we considered that the developed detection system could be applied to portable, compact, low cost system for education.

Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage (인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석)

  • Choi, Yun-Suk;Lee, In Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

Development of portable DMFC systems (휴대용 직접 메탄올 연료전지 시스템 개발)

  • Moon, Go-Young;Kim, Hyuk;Yoo, Hwang-Chan;Noh, Tae-Geun;Lee, Won-Ho
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.46-53
    • /
    • 2007
  • Direct Methanol Fuel Cell, DMFC is a potential power source for portable IT application. DMFC works at low temperature ($<100^{\circ}C$) without fuel processing. Methanol has high energy density, fuel economy, and easiness to handle. This paper focuses high efficient catalyst to increase utilization in the electrode, new membrane reducing methanol crossover, new material parts, and optimization of system integration. Lightweight and small-sized DMFC based on new materials, efficient stack, and improved system control will be applied to the 50W prototype system for the notebook computer.

  • PDF

Development of Portable Power-Efficient Bio-Signal Monitoring System using Bluetooth for the elderly and the disabled (노약자와 장애인의 건강상태를 모니터링하기 위한 소형 저 전력 휴대용 Bio-signal 측정 장치의 개발)

  • Song, Kil-Sup;Jung, Hyun-Gwon;Song, Min;Bien, Zeung-Nam;Lee, He-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.176-179
    • /
    • 2001
  • A portable bio-signal measurement system for 24-hours continuous health monitoring of the elderly and the disabled is presented. The measurement system has the functions of acquisition of various bio-signals such as ECG, EMG and EEG, wireless data transmission/receive and adjustment of parameters such as gain and cut-off frequency. The data is sent to a host computer or other device via a Bluetooth. The design targets of the developing system for volume and power consumption are $20{\times}30{\times}5(mm^3)$ and 8mW.

  • PDF

Portable urodynamics monitoring system based on ubiquitous technology (유비쿼터스 기반 휴대용 방광기능 검사 장치)

  • Kim, Keo-Sik;An, Yang-Su;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.43-45
    • /
    • 2007
  • We developed a portable urodynamics monitoring system using personal digital assistance (PDA) and proposed a new method for measuring the abdominal pressure in non invasive mode using surface EMG signals. This system is consisted of a signal conditioning and control module and could measure the vesical, abdominal and detrusor pressure. The result showed a high correlation coefficient between the practical abdominal pressure, using a conventional rectal catheter and the estimated values, by our proposed algorithm (r=0.81). This system should prove a useful tool in the future evaluations of ambulatory urodynamics monitoring study.

  • PDF

Development of Diagnostic System for Mold Oscillation in a Continuous Slab Casting Machine (연속주조기 Mold Oscillation 진단시스템 개발)

  • 이성진;전형일;이경순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.387-392
    • /
    • 2002
  • A portable mould oscillation analyzer with an integrated computer, developed by POSCO, records the movement of the mould in every spatial direction. The system uses the gap sensors to measure the mould movement (displacement) in two horizontal directions according to the mould narrow and broad faces and the vertical strokes in the four corners of mould. The gap sensor is a non-contacting minute displacement-measuring device using the principle of high frequency eddy current loss. The mould oscillation diagnostic system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. In an own expert module, which is included in the diagnosis program, one can obtain much information about the mould oscillation equipment.

  • PDF

Designing an Efficient Supply Chain System by using the Portable GPS (GPS를 사용한 효율적인 물류관리 시스템의 설계)

  • 김동연;김진일
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.57-60
    • /
    • 2001
  • Most power retailers adopt systematic, integral supply chain system to minimize the logistics cost. However, small and medium sized retail shops that don't have a distribution channel, unavoidably spend a big amount of distribution cost. This study is to propose an efficient system to manage the information of trucks by using the portable GPS. This system includes the real-time mapping of truck location, the transmission of delivery information from the truck, and the algorithm concerning the selection of the most cost efficient truck.

  • PDF

The Portable arrhythmia monitor (휴대용 부정맥 모니터에 관한 연구)

  • An, Jae-Bong;Sin, Ho-Yong;Jeong, Hyeok-Gu;Kim, Yong-Man;Lee, Myeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1986.07a
    • /
    • pp.209-211
    • /
    • 1986
  • This paper describes the design of portable arrhythmia monitor and associated algorithm for automated diagnosis based-on micro-computer in the ambulatory ECG recording, analysis, and transmitting to a hospital host computer immediately through the telephone system.

  • PDF