• 제목/요약/키워드: Portable System

검색결과 1,354건 처리시간 0.026초

Research on Real-Time Portable Quality Evaluation System for Raw Milk

  • Lee, Dae Hyun;Kim, Yong Joo;Min, Kyu Ho;Choi, Chang Hyun
    • Agribusiness and Information Management
    • /
    • 제6권2호
    • /
    • pp.32-39
    • /
    • 2014
  • The goal of this research was to develop a portable system that could be used to evaluate the quality of milk in real time at a raw milk production site. A real-time portable quality evaluation system for raw milk was developed to enable non-destructive quality evaluation of somatic cell count (SCC), fat, protein, lactose, and total solid (TS) in milk samples. A prediction model of SCC, fat, protein, lactose, and TS was constructed using partial least squares (PLS) and 200 milk samples were used to evaluate the prediction performance of the portable quality evaluation system and high performance spectroscopy. Through prediction model development and verification, it was found that the accuracy of high performance spectroscopy was 90% for SSC, 96% for fat, 96% for protein, 91% for lactose, and 97% for TS. In comparison, the accuracy of the portable quality evaluation system was relatively low, at 90% for SSC, 95% for fat, 92% for protein, 89% for lactose, 92% for TS. However, the measurement time for high performance spectroscopy was 10 minutes for 1 sample, while for the portable quality evaluation system it was 6 minutes. This means that the high performance spectroscopy system can measure 48 samples per day (8 hours), while the portable quality evaluation system can measure 80 (8 hours). Therefore, it was found that the portable quality evaluation system enables quick on-site quality evaluation of milk samples.

DEVELOPMENT OF PORTABLE NEAR INFRARED SYSTEM FOR HUMAN SKIN MOISTURE

  • Woo, Young-Ah;Ahn, Jhii-Weon;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3115-3115
    • /
    • 2001
  • In this study, portable near infrared (NIR) system was newly integrated with a photodiode array detector, which has no moving parts and this system has been successfully applied for evaluation of human skin moisture. The good correlation between NIR absorbance and absolute water content of separated hairless mouse skin was, in vitro, showed depending on the water content (7.42-84.94%) using this portable NIR system. Partial least squares (PLS) regression was used for the calibration with the 1100-1650 nm wavelength range. For the practical use for the evaluation of human skin based on moisture, PLS model for human skin moisture was, in vivo, developed using the portable NIR system based on the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. This study indicated that the portable NIR system could be a powerful tool for human skin moisture, which may be much more stable to environmental conditions such as temperature and humidity, compared to conventional methods. Furthermore, in order to confirm the performance of newly integrated portable NIR system, scanning type conventional NIR spectrometer was used in the same experiments and the results were compared.

  • PDF

LaVIEW를 이용한 휴대용 3상 소형유도전동기 회전자 바 고장 진단 시스템 개발 (The Development of Portable Rotor Bar Fault Diagnosis System for Three Phase Small Induction Motors Using LabVIEW)

  • 송명현;박규남;한동기;이태훈;우혁재
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.51-55
    • /
    • 2007
  • In this paper, a portable rotor bar fault diagnosis system for small 3 phase induction motors is suggested. For portable real-tine diagnosis system, an USB-DAQ board for collecting the 3 phase current data, three current probes, and a notebook computer are used. The LabVIEW graphical language is used for filtering, analysis, storing, and monitoring the current data. The three phase stator current are filtered and transformed to frequency level by FIT. An analysis window programed by LabVIEW is located in front panel to show the FIT results and this suggested window has a zooming function to detect the fault feature more easily near the feature frequency range which is varying by the slip frequency. To show the possibility of portable rotor bar diagnosis system, three types(healthy, one rotor bar fault, two rotor bar fault) of rotor bar are intentionally prepared and compared by the suggested window of front panel. Experimental results are shown that a suggested diagnosis system is applicable to portable diagnosis system and the rotor bar fault is detected by the frequency window in front panel programed in LabVIEW graphical language.

열차속도에 따른 GPS형 열차접근경보기의 경보안정성 분석 (A study on alarm stability using GPS type portable-alarm-system by train speed.)

  • 권기진;온정근;심재복;최영하
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1272-1277
    • /
    • 2004
  • GPS type portable-alarm-system is composed of satellite receiving equipment, signal transmission equipment, etc. Time errors occur because of the processing methods of the satellite receiving equipment and signal generator, the positional error of GPS itself, etc. With the recent rise of train speed, it becomes very important to secure the stability of portable-alarm-system from time errors, The present study estimated errors caused by the structure of portable-alarm-system, GPS errors. etc., and verified them. In addition, it examined the effects of such errors on portable-alarm-system according to train speed.

  • PDF

스마트폰과 연동한 휴대용 심전도계 (A Portable ECG System Coupled with a Smartphone)

  • 김기완;안종현;박광민
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.7-11
    • /
    • 2021
  • The electrocardiogram(ECG) and heart rates are essential for diagnosing heart disease. However, conventional portable ECG devices are possible to only measure heart rates or have limitations in how and where they are measured. In this paper, a portable ECG system in which ECG waveforms and heart rates are displayed on smartphone screens is developed. A smartphone is used as display equipment instead of a computer screen for continuous monitoring. The developed ECG system filters and amplifies detected analog ECG signals. Next, it converts the amplified analog ECG signals into digital signals, then transmits to the smartphone via Bluetooth communication. This ECG system can display and store biomedical signals on a smartphone through the application. As a result, the waveform and heart rates of the developed portable ECG system has been confirmed to be similar to those of existing medical devices.

시각 장애인을 위한 Android OS 기반의 Portable Navigation System 설계 및 구현 과 N : N Service (The Design and Implementation Android OS Based Portable Navigation System For Visually Impaired Person and N : N Service)

  • 공성훈;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.327-330
    • /
    • 2012
  • 도시의 급격한 발전으로 공사의 증가가 증가하게 되고 이동 차량 또한 증가 하게 된다. 이는 자연히 시각 장애인들의 보행을 점점 더 어렵게 만든다. 이러한 어려움을 해결하고자 Android 기반의 Portable Navigation System을 도입하여 시각 장애인의 보행을 돕고, 서비스 센터에서 시각 장애인의 이동을 실시간으로 모니터링 하여서 시각 장애인의 보행에 도움을 주고자 한다. 노인이 서비스 센터에 배치되어 노인 인구 증가 문제의 해소 방안도 제공한다. 시각 장애인이 들고 다닐 수 있는 형태의 Android 기반의 Portable Navigation System은 GPS, Camera, Audio, wifi를 가지고 있어, GPS위치 정보와 Camera 영상 정보를 실시간으로 wifi망을 이용해 서비스 센터로 전송을 하여 주고, 서비스 센터에서 시각 장애인의 GPS Location 정보를 바탕으로 그 위치를 지도에 표시하고, Camera 영상 정보로 시각 장애인이 바라보고 있는 곳의 상황을 모니터링 하며, Audio를 통해, 실시간으로 대화를 통해서 길안내 해주는 Navigation System이다.

  • PDF

신경회로망을 이용한 휴대용 E-Nose 시스템 개발 (Design of Portable E-Nose System using Neural Network Algorithm)

  • 김정도;김동진;함유경;홍철호;변형기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.39-42
    • /
    • 2004
  • We have designed a portable electronic nose(e-nose) system using an array of commercial gas sensors for recognition and analyzing the various odours. In this paper, we have implemented a portable e-nose system using an array gas sensors and personal digital assistants(PDA) for recognizing and analyzing volatile organic compounds(VOCs) in the field. Field screening for pollutants has been a target of instrumental development for number of year. A portable e-nose system can be substantial benefit to rapidly localize the spacial extent of a pollution or to find pollutants source. And, by using PDA, E-nose have a better function such as the easy user-interface and data transfer by internet from on- site to remote computer. We adapted the Levenberg-Marquardt algorithm based on the back-propagation and proposed the method that could be predicted concentration levels of VOCs gases after classification by separating neural network into two parts.

  • PDF

육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가 (Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats)

  • 김재곤;조병관
    • 농업과학연구
    • /
    • 제38권3호
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

FES 보행을 위한 휴대용 보행 이벤트 검출 시스템 (Portable Gait-Event Detection System for FES Locomotion)

  • 공세진;김철승;박관용;엄광문
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.248-253
    • /
    • 2006
  • The purpose of this study is to develop a portable gait-event detection system which is necessary for the cycle-to-cycle FES(functional electrical stimulation) control of locomotion. To make the system portable, we made following modifications in the gait signal measurement system. That is, 1) to make the system wireless using Bluetooth communication, 2) to make the system small-sized and battery-powered by using low power consumption ${\mu}$ P(ATmega8535L). The gait-events were analyzed in off-line at the main computer using ANN(Artificial Neural Network). The Proposed system showed no mis-detection of the gait-events of normal subject and hemiplegia subjects. The performance of the system was better than the previous wired-system.

마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치 (A portable multichannel FES system for control of paralyzed extremities)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF